Experimental investigation of startup behaviors of a dual compensation chamber loop heat pipe with insufficient fluid inventory

被引:53
作者
Bai, Lizhan [1 ]
Lin, Guiping [1 ]
Wen, Dongsheng [2 ]
Feng, Jianting [1 ]
机构
[1] Beihang Univ, Sch Aeronaut Sci & Engn, Beijing 100191, PR, Peoples R China
[2] Univ London, Sch Mat Sci & Engn, London E1 4NS, England
基金
中国国家自然科学基金;
关键词
Dual compensation chamber; Loop heat pipe; Startup; Spacecraft thermal control; Electronic cooling; TECHNOLOGY;
D O I
10.1016/j.applthermaleng.2008.06.019
中图分类号
O414.1 [热力学];
学科分类号
摘要
To address the problem of the relative orientation limit between the evaporator and the compensation chambers (CCs), a dual-compensation chamber loop heat pipe (DCCLHP) was developed, and its startup characteristics with small heat loads and insufficient fluid inventory were experimentally investigated in this work. Based on the experimental results, the conclusions below can be drawn: (1) The DCCLHP can start up reliably at small heat loads, but sometimes the temperature overshoot is rather high. (2) The startup performance of the DCCLHP is different when its evaporator and CCs are at different attitudes due to different liquid/vapor composition in the evaporator and heat leak from the evaporator to the CCs, (3) In general, evaporation in the evaporator core is inevitable, which results in a large heat leak from the evaporator to the CCs and generates large temperature overshoot during the startup process. (4) Because the superheat of liquid to initiate nucleate boiling reduces as its temperature rises, nucleate boiling can also occur in the vapor grooves although the temperature of the evaporator rises at the same rate as that of the CCs. (5) The startup performance of LHPs mainly depends on the heat load and thermal resistance between the evaporator and CCs. When the startup heat load is big enough, the DCCLHP has no start-up difficulty. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1447 / 1456
页数:10
相关论文
共 29 条
[1]  
Baumann J., 2000, 20002285 AIAA
[2]  
BAUMANN J, 1999, 1999012048 SAE
[3]   Steady-state and transient performance of a miniature loop heat pipe [J].
Chen, Yuming ;
Groll, Manfred ;
Mertz, Rainer ;
Maydanik, Yu F. ;
Vershinin, S. V. .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2006, 45 (11) :1084-1090
[4]   Operating temperature and distribution. of a working fluid in LHP [J].
Chernysheva, M. A. ;
Vershinin, S. V. ;
Maydanik, Yu. F. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2007, 50 (13-14) :2704-2713
[5]  
Cheung K., 1998, INT C ENV SYST DANV
[6]  
Gerhart C., 1999, P 11 INT HEAT PIP C
[7]  
Gluck D., 1999, CHARACTERIZATION HIG
[8]  
HOANG TT, 2005, 20055630 AIAA
[9]  
Khrustalev D, 2001, P SOC PHOTO-OPT INS, V4428, P375
[10]  
Ku J., 1999, P INT C EV SYST DENV