2D-to-3D X-ray breast image registration

被引:0
作者
Bakic, Predrag R. [1 ]
Richard, Frederic J. P.
Maidment, Andrew D. A.
机构
[1] Univ Penn, Philadelphia, PA 19104 USA
[2] Univ Paris 05, Paris, France
来源
BIOMEDICAL IMAGE REGISTRATION, PROCEEDINGS | 2006年 / 4057卷
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Digital breast tomosynthesis combines the advantages of digital mammography and 3D breast imaging. To facilitate the comparison of new tomosynthesis images with previous mammographic exams of the same woman, there is a need for a method to register a mammogram with tomosynthetic images of the same breast; this is the focus of our paper. We have chosen to approach this multimodality registration problem by registering a mammogram with individual tomosynthesis source projection images. In this paper, we analyzed the results of registering an MLO mammogram to nine tomosynthesis source projection images of the same breast. On average, we were able to compensate 90 percent of the per-pixel intensity differences that existed between the two images before registration.
引用
收藏
页码:84 / 91
页数:8
相关论文
共 10 条
[1]  
ARTON AK, 2006, P SPIE, V6142
[2]  
BAKIC P, 2006, IN PRESS P 8 INT WOR
[3]   Mammogram synthesis using a 3D simulation. 1. Breast tissue model and image acquisition simulation [J].
Bakic, PR ;
Albert, M ;
Brzakovic, D ;
Maidment, ADA .
MEDICAL PHYSICS, 2002, 29 (09) :2131-2139
[4]  
BOONE JM, 2006, P SOC PHOTO-OPT INS, V5745, P319
[5]   Computer-aided detection system for breast masses on digital tomosynthesis mammograms: Preliminary experience [J].
Chan, HP ;
Wei, J ;
Sahiner, B ;
Rafferty, EA ;
Wu, T ;
Roubidoux, MA ;
Moore, RH ;
Kopans, DB ;
Hadjiiski, LM ;
Helvie, MA .
RADIOLOGY, 2005, 237 (03) :1075-1080
[6]   Three-dimensional imaging of breast calcifications [J].
Maidment, ADA ;
Albert, M ;
Conant, EF .
EXPLOITING NEW IMAGE SOURCES AND SENSORS, 26TH AIPR WORKSHOP, 1998, 3240 :200-208
[7]   Digital Tomosynthesis in breast imaging [J].
Niklason, LT ;
Christian, BT ;
Niklason, LE ;
Kopans, DB ;
Castleberry, DE ;
OpsahlOng, BH ;
Landberg, CE ;
Slanetz, PJ ;
Giardino, AA ;
Moore, R ;
Albagli, D ;
DeJule, MC ;
Fitzgerald, PF ;
Fobare, DF ;
Giambattista, BW ;
Kwasnick, RF ;
Liu, JQ ;
Lubowski, SJ ;
Possin, GE ;
Richotte, JF ;
Wei, CY ;
Wirth, RF .
RADIOLOGY, 1997, 205 (02) :399-406
[8]   Computerized mass detection for digital breast tomosynthesis directly from the projection images [J].
Reiser, I ;
Nishikawa, RM ;
Giger, ML ;
Wu, T ;
Rafferty, EA ;
Moore, R ;
Kopans, DB .
MEDICAL PHYSICS, 2006, 33 (02) :482-491
[9]   Mammogram registration: A phantom-based evaluation of compressed breast thickness variation effects [J].
Richard, FJP ;
Bakic, PR ;
Maidment, ADA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (02) :188-197
[10]  
Richard FJP, 2003, COMPUT VIS IMAGE UND, V89, P166, DOI [10.1016/S1077-3142(03)00006-7, 10.1016/S 1077-3142(03)00006-7]