Comparative study of automated plateletpheresis using five different apheresis systems in a tertiary care hospital

被引:22
作者
Chaudhary, Rajendra [1 ]
Das, Sudipta Sekhar [1 ]
Khetan, Dheeraj [1 ]
Ojha, Shashank [1 ]
Verma, Sunil [1 ]
机构
[1] Sanjay Gandhi Postgrad Inst Med Sci, Dept Transfus Med, Lucknow 226014, Uttar Pradesh, India
关键词
Plateletpheresis; Cell separator; Donor safety; Platelet yield; DONORS; PLATELETS; YIELD; CELLS;
D O I
10.1016/j.transci.2009.01.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Different types of cell separators are available nowadays based on either continuous intermittent flow technology to meet the growing demands for single donor apheresis platelets. This prospective Study compares the five machines used in our center with regard to procedure parameters, product quality and adverse effects oil the donor. A total of 477 plateletpheresis on various machines were performed on eligible donors over a period of 28 months after taking informed consent. All procedures were performed following the departmental standard operating procedure (SOP) and manufacturer's instructions. All donor and procedure related details were obtained from the procedure register. Statistical analysis was done using the SPSS statistical package (version 12, USA). The median age, BSA and BMI of our plateletpheresis donors were calculated to be 29 years, 1.69 m(2) and 23.1 kg/m(2), respectively. Analyzing the parameters related to donor comfort such as donation time (DT), needle time (NT) and processing time (PT), the MCS machines were not "donor friendly" compared to Amicus and Fresenius. Platelet yield by Amicus was significantly higher as compared to other cell separators (p < 0.05). Plateletpheresis associated citrate toxicity was higher with the Amicus and MCS 3p and vasovagal side-effects was observed least with the CS 3000 machine. Though, quality of apheresis product in terms of yield is comparable with all the machines, there are differences in the systems with regard to donor safety, procedure time and donor retention. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:99 / 103
页数:5
相关论文
共 24 条
  • [1] [Anonymous], 2007, Guide to the preparation, use and quality assurance of blood components, V13
  • [2] COMPARISON OF PLATELETPHERESIS USING 2 CELL SEPARATORS AND IDENTICAL DONORS
    BERTHOLF, MF
    MINTZ, PD
    [J]. TRANSFUSION, 1989, 29 (06) : 521 - 523
  • [3] Boogaerts M A, 1987, Transfus Med Rev, V1, P186, DOI 10.1016/S0887-7963(87)70021-2
  • [4] Brecher ME., 2005, Technical Manual, V15th
  • [5] Burgstaler EA, 1999, J CLIN APHERESIS, V14, P163, DOI 10.1002/(SICI)1098-1101(1999)14:4<163::AID-JCA2>3.3.CO
  • [6] 2-V
  • [7] Effect of donor variables on yield in single donor plateletpheresis by continuous flow cell separator
    Chaudhary, R
    Das, SS
    Khetan, D
    Sinha, P
    [J]. TRANSFUSION AND APHERESIS SCIENCE, 2006, 34 (02) : 157 - 161
  • [8] Quality systems in automated plateletpheresis in hospital-based blood transfusion service in north India
    Chaudhary, R
    Das, SS
    Agarwal, P
    Shukla, JS
    [J]. JOURNAL OF CLINICAL APHERESIS, 2005, 20 (02) : 81 - 85
  • [9] Lowering the hemoglobin cutoff for female plateletpheresis donors
    Fraser, JL
    Whatmough, A
    Uhl, L
    Kruskall, MS
    [J]. TRANSFUSION, 1998, 38 (09) : 855 - 859
  • [10] Economic impact of donor platelet count and platelet yield in apheresis products: Relevance for emerging issues in platelet transfusion therapy
    Goodnough, LT
    Ali, S
    Despotis, G
    Dynis, M
    DiPersio, JF
    [J]. VOX SANGUINIS, 1999, 76 (01) : 43 - 49