Adjustable 6-0 polypropylene flanged technique for scleral fixation, part 2: repositioning of subluxated IOLs

被引:15
作者
Assia, Ehud, I [1 ,2 ,3 ]
Wong, John X. H. [4 ]
机构
[1] Meir Med Ctr, Dept Ophthalmol, Kefar Sava, Israel
[2] Tel Aviv Univ, Sackler Sch Med, Tel Aviv, Israel
[3] Ein Tal Eye Ctr, Tel Aviv, Israel
[4] Tan Tock Seng Hosp, Natl Healthcare Grp Eye Inst, Singapore, Singapore
关键词
INTRAOCULAR-LENS FIXATION; EYES;
D O I
10.1097/j.jcrs.0000000000000261
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To describe the technique of modified adjustable flange scleral fixation using 6-0 polypropylene sutures for repositioning of subluxated intraocular lenses (IOLs). Setting: Center for Applied Eye Research, Meir Medical Center, and the Ein-Tal Eye Center, Israel. Design: Case series. Methods: Subluxated capsular-fixated posterior chamber IOLs are secured to the sclera using 6-0 polypropylene sutures looped around the IOL haptics. This method can be performed for any type of IOL: hydrophobic, hydrophilic, silicone, or poly(methyl methacrylate); 1-piece or 3-piece; and with either closed-loop or open-loop haptics. It can also be used in conjunction with capsular stabilizing devices. Results: In the 18 cases performed, successful repositioning with stable and central fixation of the IOLs was achieved. One eye required a repeated surgery due to suture slippage. The eyes recovered relatively quickly with noted quiescence as early as 1 week postoperatively. Patients did not complain of ocular irritation from the subconjunctival flange up to the 6-month follow-up period. In 1 case, a flange was exposed postoperatively but the patient refused additional intervention and developed intraocular infection 7 months postoperatively. Conclusions: The adjustable 6-0 polypropylene flanged technique for IOL repositioning and scleral fixation was a relatively quick and simple method for management of subluxated IOLs. Complete coverage of the flange by conjunctiva and Tenon layer must be confirmed at the end of surgery. Copyright (C) 2020 Published by Wolters Kluwer on behalf of ASCRS and ESCRS
引用
收藏
页码:1392 / 1396
页数:5
相关论文
共 10 条
[1]   Fibrin glue-assisted sutureless posterior chamber intraocular lens implantation in eyes with deficient posterior capsules [J].
Agarwal, Amar ;
Kumar, Dhivya Ashok ;
Jacob, Soosan ;
Baid, Chandresh ;
Agarwal, Athiya ;
Srinivasan, Sridhar .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09) :1433-1438
[2]   Epidemiology, Etiology, and Prevention of Late IOL-Capsular Bag Complex Dislocation: Review of the Literature [J].
Ascaso, Francisco J. ;
Huerva, Valentin ;
Grzybowski, Andrzej .
JOURNAL OF OPHTHALMOLOGY, 2015, 2015
[3]  
Canabrava A., NOVEL 4 FLANGED INTR
[4]  
Canabrava B., 4 FLANGED TECHNIQUE
[5]  
Canabrava C., VIDEO J CATATARACT R
[6]   Incidence and risk factors of late in-the-bag intraocular lens dislocation: Evaluation of 140 eyes between 1992 and 2012 [J].
Dabrowska-Kloda, Kinga ;
Kloda, Tomasz ;
Boudiaf, Sara ;
Jakobsson, Gurmar ;
Stenevi, Ulf .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (07) :1376-1382
[7]   Sutureless intrascleral posterior chamber intraocular lens fixation [J].
Gabor, Scharioth G. B. ;
Pavlidis, Mitrofanis M. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (11) :1851-1854
[8]   Sutureless 27-gauge needle-assisted transconjunctival intrascleral intraocular lens fixation: Initial experience [J].
Kelkar, Aditya Shrikant ;
Fogla, Rajesh ;
Kelkar, Jai ;
Kothari, Akshay Anil ;
Mehta, Hetal ;
Amoaku, Winfried .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (12) :1450-1453
[9]   Frequency of Intraocular Lens Dislocation and Pseudophacodonesis, 20 Years After Cataract Surgery - A Prospective Study [J].
Monestam, Eva .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 198 :215-222
[10]   Flanged Intrascleral Intraocular Lens Fixation with Double-Needle Technique [J].
Yamane, Shin ;
Sato, Shimpei ;
Maruyama-Inoue, Maiko ;
Kadonosono, Kazuaki .
OPHTHALMOLOGY, 2017, 124 (08) :1136-1142