Acoustic emission vis-a-vis electrochemical techniques for corrosion monitoring of reinforced concrete element

被引:41
作者
Patil, Shilpa [1 ]
Karkare, Bilavari [2 ]
Goyal, Shweta [1 ]
机构
[1] Thapar Univ, Dept Civil Engn, Patiala 147004, Punjab, India
[2] Vishwakarma Inst Informat Technol, Pune 411048, Maharashtra, India
关键词
Reinforced concrete; Rebar corrosion; Accelerated corrosion; Acoustic emission; Corrosion current density; DAMAGE; INITIATION; REBAR;
D O I
10.1016/j.conbuildmat.2014.06.068
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Corrosion of steel reinforcement and subsequent cracking of concrete is a major cause for deterioration of reinforced concrete (RC) structures. For safety of structures early detection of deterioration by means of non-destructive testing is the need of the day. Comparative study of acoustic emission (AE) and electrochemical techniques for an experimental investigation of corrosion of steel embedded in concrete is presented here. The results show two stages of corrosion process and also indicate that, cumulative signal strength can be used as a promising parameter of AE technique to monitor progress of damage in RC due to corrosion. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:326 / 332
页数:7
相关论文
共 26 条
[1]  
[Anonymous], 2006, E1316 ASTM
[2]  
[Anonymous], 1959, IS516
[3]  
[Anonymous], 2002, 3831970 IS
[4]   Influence of impressed current on the initiation of damage in reinforced mortar due to corrosion of embedded steel [J].
Care, Sabine ;
Raharinaivo, Andre .
CEMENT AND CONCRETE RESEARCH, 2007, 37 (12) :1598-1612
[5]   Acoustic emission monitoring of CFRP reinforced concrete slabs [J].
Degala, Sandeep ;
Rizzo, Piervincenzo ;
Ramanathan, Karthik ;
Harries, Kent A. .
CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (05) :2016-2026
[6]   Acoustic Emission Monitoring of Reinforced Concrete under Accelerated Corrosion [J].
Di Benedetti, M. ;
Loreto, G. ;
Matta, F. ;
Nanni, A. .
JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2013, 25 (08) :1022-1029
[7]   Short-term corrosion rate measurement of OPC and HPC reinforced concrete specimens by electrochemical techniques [J].
El-Gelany, MA .
MATERIALS AND STRUCTURES, 2001, 34 (241) :426-432
[8]   Site installation and testing of a continuous acoustic monitoring [J].
Fricker, Stephan ;
Vogel, Thomas .
CONSTRUCTION AND BUILDING MATERIALS, 2007, 21 (03) :501-510
[9]   Corrosion of steel reinforcements embedded in FRP wrapped concrete [J].
Gadve, Sangeeta ;
Mukherjee, A. ;
Malhotra, S. N. .
CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (01) :153-161
[10]   Study and characterization by acoustic emission and electrochemical measurements of concrete deterioration caused by reinforcement steel corrosion [J].
Idrissi, H ;
Limam, A .
NDT & E INTERNATIONAL, 2003, 36 (08) :563-569