The collagen structure of bovine intervertebral disc studied using polarization-sensitive optical coherence tomography

被引:52
作者
Matcher, SJ [1 ]
Winlove, CP [1 ]
Gangnus, SV [1 ]
机构
[1] Univ Exeter, Sch Phys, Biomed Phys Grp, Exeter EX4 4QL, Devon, England
关键词
D O I
10.1088/0031-9155/49/7/016
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polarization-sensitive optical coherence tomography (PS-OCT) is used to measure the birefringence properties of bovine intervertebral disc and equine flexor tendon. For equine tendon the birefringence Deltan is (6.0 +/- 0.2) x 10(-3) at a wavelength of 1.3 mum. This is somewhat larger than the values reported for bovine tendon. The surface region of the annulus fibrosus of a freshly excised intact bovine intervertebral disc displays an identical value of birefringence, Deltan = (6.0 +/- 0.6) x 10(-3) at 1.3 mum. The nucleus pulposus does not display birefringence, the measured apparent value of Deltan = (0.39 +/- 0.01) x 10(-3) being indistinguishable from the effects of depolarization due to multiple scattering. A clear difference is found between the depth-resolved retardance of equine tendon and that of bovine intervertebral disc. This apparently relates to the lamellar structure of the latter tissue, in which the collagen fibre orientation alternates between successive lamellae. A semi-empirical model based on Jones calculus shows that the measurements are in reasonable agreement with previous optical and x-ray data. These results imply that PS-OCT could be a useful tool to study collagen organization within the intervertebral disc in vitro and possibly in vivo and its variation with applied load and disease.
引用
收藏
页码:1295 / 1306
页数:12
相关论文
共 21 条
[1]   Polarization-sensitive optical coherence tomography of dental structures [J].
Baumgartner, A ;
Dichtl, S ;
Hitzenberger, CK ;
Sattmann, H ;
Robl, B ;
Moritz, A ;
Fercher, ZF ;
Sperr, W .
CARIES RESEARCH, 2000, 34 (01) :59-69
[2]  
BEADLE OA, 1931, MRC SPECIAL REPORTS, V161
[3]   Determination of the depth-resolved Stokes parameters of light backscattered from turbid media by use of polarization-sensitive optical coherence tomography [J].
de Boer, JF ;
Milner, TE ;
Nelson, JS .
OPTICS LETTERS, 1999, 24 (05) :300-302
[4]   Monte Carlo modeling of polarized light propagation in a biological tissue [J].
Gangnus, SV ;
Matcher, SJ ;
Meglinski, IV .
COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS VI, 2002, 4619 :281-288
[5]   Ultrahigh-resolution optical coherence tomography using continuum generation in an air-silica microstructure optical fiber [J].
Hartl, I ;
Li, XD ;
Chudoba, C ;
Ghanta, RK ;
Ko, TH ;
Fujimoto, JG ;
Ranka, JK ;
Windeler, RS .
OPTICS LETTERS, 2001, 26 (09) :608-610
[6]   POLARIZATION-SENSITIVE LOW-COHERENCE REFLECTOMETER FOR BIREFRINGENCE CHARACTERIZATION AND RANGING [J].
HEE, MR ;
HUANG, D ;
SWANSON, EA ;
FUJIMOTO, JG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1992, 9 (06) :903-908
[7]   Measurement and imaging of birefringence and optic axis orientation by phase resolved polarization sensitive optical coherence tomography [J].
Hitzenberger, CK ;
Götzinger, E ;
Sticker, M ;
Pircher, M ;
Fercher, AF .
OPTICS EXPRESS, 2001, 9 (13) :780-790
[8]   In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomograghy [J].
Izatt, JA ;
Kulkami, MD ;
Yazdanfar, S ;
Barton, JK ;
Welch, AJ .
OPTICS LETTERS, 1997, 22 (18) :1439-1441
[9]   Optical coherence tomography and microscopy in gastrointestinal tissues [J].
Izatt, JA ;
Kulkarni, MD ;
Wang, HW ;
Kobayashi, K ;
Sivak, MV .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1996, 2 (04) :1017-1028
[10]   Contrast mechanisms in polarization-sensitive Mueller-matrix optical coherence tomography and application in burn imaging [J].
Jiao, SL ;
Yu, WR ;
Stoica, G ;
Wang, LHV .
APPLIED OPTICS, 2003, 42 (25) :5191-5197