Engineering design for the magnetic diagnostics of Wendelstein 7-X

被引:37
|
作者
Endler, M. [1 ]
Brucker, B. [1 ]
Bykov, V. [1 ]
Cardella, A. [1 ]
Cads, A. [1 ]
Dobmeier, F. [1 ]
Dudek, A. [1 ]
Fellinger, J. [1 ]
Geiger, J. [1 ]
Grosser, K. [1 ]
Grulke, O. [1 ]
Hartmann, D. [1 ]
Hathiramani, D. [1 ]
Hoechel, K. [1 ]
Koeppen, M. [1 ]
Laube, R. [1 ]
Neuner, U. [1 ]
Peng, X. [1 ]
Rahbarnia, K. [1 ]
Rummel, K. [1 ]
Sieber, T. [1 ]
Thiel, S. [1 ]
Vorkoeper, A. [1 ]
Werner, A. [1 ]
Windisch, T. [1 ]
Ye, M. Y. [1 ]
机构
[1] Max Planck Inst Plasma Phys, D-17491 Greifswald, Germany
关键词
Stellarator; Wendelstein; 7-X; Magnetic diagnostics; ANISOTROPIC PRESSURE; W7-X; PHYSICS; OPERATION; PLASMA;
D O I
10.1016/j.fusengdes.2015.07.020
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The magnetic diagnostics foreseen for the Wendelstein 7-X (W7-X) stellarator are diamagnetic loops to measure the plasma energy, Rogowski coils to measure the toroidal plasma current, saddle coils to measure the Pfirsch-Schluter currents, segmented Rogowski coils (poloidal magnetic field probes) to add information on the distribution of the plasma current density, and Mirnov coils to observe magnetohy-drodynamic modes. All these magnetic field sensors were designed as classical pick-up coils, after the time integration of induced signals for 1/2 hour had been successfully demonstrated. The long-pulse operation planned for W7-X causes nevertheless significant challenges to the design of these diagnostics, in particular for the components located inside the plasma vessel, which may be exposed to high levels of microwave (electron cyclotron resonance) stray radiation and thermal radiation. This article focuses on the tests and modelling performed during the development of the magnetic diagnostics and on the design solutions adopted to meet the conflicting requirements. All pick-up coils foreseen for the initial operation phase of W7-X and their signal cable sections inside the plasma vessel and the cryostat are now installed, and their electronics and data acquisition are under preparation. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:468 / 494
页数:27
相关论文
共 50 条
  • [1] Continuous data acquisition with online analysis for the Wendelstein 7-X magnetic diagnostics
    Hennig, Ch.
    Werner, A.
    Marquardt, M.
    Bluhm, I.
    Kroiss, H.
    Kuehner, G.
    Heimann, P.
    Maier, J.
    Riemann, H.
    Zilker, M.
    FUSION ENGINEERING AND DESIGN, 2008, 83 (2-3) : 321 - 325
  • [2] Design and construction of WENDELSTEIN 7-X
    Wanner, M
    Feist, JH
    Renner, H
    Sapper, J
    Schauer, F
    Schneider, H
    Erckmann, V
    Niedermeyer, H
    FUSION ENGINEERING AND DESIGN, 2001, 56-57 : 155 - 162
  • [3] Microwave stray radiation: Measures for steady state diagnostics at Wendelstein 7-X
    Hathiramani, Dag
    Binder, Roland
    Brakel, Rudolf
    Broszat, Torsten
    Brucker, Bertram
    Cardella, Antonino
    Endler, Michael
    Grosser, Klaus
    Hirsch, Matthias
    Laqua, Heinrich
    Thiel, Stefan
    FUSION ENGINEERING AND DESIGN, 2013, 88 (6-8) : 1232 - 1235
  • [4] Plans for the first plasma operation of Wendelstein 7-X
    Pedersen, T. Sunn
    Andreeva, T.
    Bosch, H. -S.
    Bozhenkov, S.
    Effenberg, F.
    Endler, M.
    Feng, Y.
    Gates, D. A.
    Geiger, J.
    Hartmann, D.
    Hoelbe, H.
    Jakubowski, M.
    Koenig, R.
    Laqua, H. P.
    Lazerson, S.
    Otte, M.
    Preynas, M.
    Schmitz, O.
    Stange, T.
    Turkin, Y.
    NUCLEAR FUSION, 2015, 55 (12)
  • [5] Organizing Wendelstein 7-X device operation
    van Eeten, P.
    Bosch, H. S.
    Brakel, R.
    Degenkolbe, S.
    FUSION ENGINEERING AND DESIGN, 2020, 160
  • [6] Setup and initial results from the magnetic flux surface diagnostics at Wendelstein 7-X
    Otte, M.
    Assmus, D.
    Biedermann, C.
    Bozhenkov, S.
    Braeuer, T.
    Dudek, A.
    Geiger, J.
    Kocsis, G.
    Lazerson, S.
    Pedersen, T. S.
    Schauer, F.
    Szepesi, T.
    Standley, B.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2016, 58 (06)
  • [7] Probe manipulators for Wendelstein 7-X and their interaction with the magnetic topology
    Rack, M.
    Hoeschen, D.
    Reiter, D.
    Unterberg, B.
    Coenen, J. W.
    Brezinsek, S.
    Neubauer, O.
    Bozhenkov, S.
    Czymek, G.
    Liang, Y.
    Hubeny, M.
    Linsmeier, Ch
    PLASMA SCIENCE & TECHNOLOGY, 2018, 20 (05)
  • [8] Influence of construction errors on Wendelstein 7-X magnetic configurations
    Andreeva, T.
    Braeuer, T.
    Endler, M.
    Kisslinger, J.
    v. Toussaint, U.
    FUSION ENGINEERING AND DESIGN, 2009, 84 (2-6) : 408 - 412
  • [9] Bayesian modelling of multiple plasma diagnostics at Wendelstein 7-X
    Kwak, Sehyun
    Hoefel, U.
    Krychowiak, M.
    Langenberg, A.
    Svensson, J.
    Mora, H. Trimino
    Ghim, Y. -C.
    NUCLEAR FUSION, 2024, 64 (10)
  • [10] ICRF heating for Wendelstein 7-X
    Wesner, F
    Hartmann, DA
    Birus, D
    Braun, F
    Wendorf, J
    FUSION ENGINEERING AND DESIGN, 2003, 66-68 : 561 - 566