Test-retest reliability of stride length-cadence gait relationship in Parkinson's disease

被引:6
|
作者
Ambrus, Mira
Sanchez, Jose A.
Sanchez Miguel, Jose A.
del-Olmo, Fernandez
机构
[1] King Juan Carlos Univ, Fac Sci Sport & Phys Educ, Area Sport Sci, Ave Atenas S-N, Madrid 28992, Spain
[2] Univ A Coruna, Dept Sport Sci, Av Ernesto Che Guevara 112, La Coruna, Spain
关键词
Parkinson's disease; Gait; Stride length - cadence relationship; INTRACLASS CORRELATION-COEFFICIENT; PHYSICAL-THERAPY;
D O I
10.1016/j.gaitpost.2019.05.009
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Introduction: The gait pattern in Parkinson's disease (PD) subjects is characterized by a specific deficit of the internal regulation of the stride length (SL), while the control of the cadence (Cad) remains intact. The purpose of the present study was to evaluate the reliability of the stride length-cadence relationship (SLCrel) in a group of PD subjects. Methods: Thirty five PD subjects performed two sessions, separated by a three month resting period. In each session Gait speed, SL and Cad were evaluated at five different self-selected speed conditions: preferred, slow, very slow, fast and very fast. Linear regression analysis was used to explore the SLCrel and to determine the slope, intercept and coefficient of determination (R-2) for each participant. Test-retest reliability for the slope and intercept was calculated using intra-class correlation coefficient (ICC), 95% confidence interval (CI), and standard error of mean (SEM). Results: There were no significant differences in the slope and intercept between the two sessions. The overall speed was significantly faster in the second session compared with the first one (F = 4.60, p = 0.03). The SLCrel showed high reliability across the sessions (ICC = 0.89 and ICC = 0.91; 95% CI = 0.80 - 0.95 and 95% CI = 0.82 - 0.95; SEM = 0.002 and SEM = 0.073, for the slope and interception, respectively). Conclusions: The SLCrel in Parkinsonian gait is a reproducible measure across a period of three months, and may be a useful tool to explore the specificity of gait rehabilitation interventions in PD subjects.
引用
收藏
页码:177 / 180
页数:4
相关论文
共 50 条
  • [21] Test-retest repeatability of assessing environmental and lifestyle factors in Parkinson's disease
    Yip, Chun-Wai
    Tan, Eng-King
    MOVEMENT DISORDERS, 2008, 23 (07) : 1032 - 1036
  • [22] Test-Retest Reliability of the MotionMetrix Software for the Analysis of Walking and Running Gait Parameters
    Jaen-Carrillo, Diego
    Ruiz-Alias, Santiago A.
    Chicano-Gutierrez, Jose M.
    Ruiz-Malagon, Emilio J.
    Roche-Seruendo, Luis E.
    Garcia-Pinillos, Felipe
    SENSORS, 2022, 22 (09)
  • [23] Clinical Disease Severity Mediates the Relationship between Stride Length and Speed and the Risk of Falling in Parkinson's Disease
    Lai, Yun-Ru
    Lien, Chia-Yi
    Huang, Chih-Cheng
    Lin, Wei-Che
    Chen, Yueh-Sheng
    Yu, Chiun-Chieh
    Cheng, Ben-Chung
    Kung, Chia-Te
    Kung, Chien-Feng
    Chiang, Yi-Fang
    Hung, Yun-Ting
    Chang, Hsueh-Wen
    Lu, Cheng-Hsien
    JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (02):
  • [24] Computerized Dual-Task Testing of Gait and Visuospatial Cognitive Functions; Test-Retest Reliability and Validity
    Szturm, Tony J.
    Sakhalkar, Vedant S.
    Kanitkar, Anuprita
    Nankar, Mayur
    FRONTIERS IN HUMAN NEUROSCIENCE, 2017, 11 : 1 - 11
  • [25] Hands-feet wireless devices: Test-retest reliability and discriminant validity of motor measures in Parkinson's disease telemonitoring
    Maremmani, Carlo
    Rovini, Erika
    Salvadori, Stefano
    Pecori, Alessandro
    Pasquini, Jacopo
    Ciammola, Andrea
    Rossi, Simone
    Berchina, Giulia
    Monastero, Roberto
    Cavallo, Filippo
    ACTA NEUROLOGICA SCANDINAVICA, 2022, 146 (03): : 304 - 317
  • [26] Test-retest reliability and measurement error of the modified gait efficacy scale in individuals with stroke
    Avelino, Patrick R.
    Nascimento, Lucas R.
    Menezes, Kenia K. P.
    Alvarenga, Maria Tereza Mota
    Faria Fortini, Iza
    Teixeira-Salmela, Luci F.
    PHYSIOTHERAPY THEORY AND PRACTICE, 2022, 38 (13) : 2956 - 2961
  • [27] Test-Retest Reliability and Criterion Validity of the Spanish Version of Two Motor Imagery Questionnaires in People With Parkinson Disease
    Moreno-Verdu, Marcos
    del Rosario Ferreira-Sanchez, Maria
    Martin-Casas, Patricia
    de los Angeles Atin-Arratibel, Maria
    JOURNAL OF NEUROLOGIC PHYSICAL THERAPY, 2023, 47 (01): : 35 - 43
  • [28] Test-retest reliability of stride time variability while dual tasking in healthy and demented adults with frontotemporal degeneration
    Olivier Beauchet
    Ellen Freiberger
    Cedric Annweiler
    Reto W Kressig
    Francois R Herrmann
    Gilles Allali
    Journal of NeuroEngineering and Rehabilitation, 8
  • [29] Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite)
    Van Uden C.J.T.
    Besser M.P.
    BMC Musculoskeletal Disorders, 5 (1)
  • [30] Stride length regulation in Parkinson's disease: the use of extrinsic, visual cues
    Lewis, GN
    Byblow, WD
    Walt, SE
    BRAIN, 2000, 123 : 2077 - 2090