In this paper, we describe an InGaAs detector based radiation thermometer (IRT) and new design of fixed-point blackbodies, including Sn, Zn, Al and Cu, for the establishment of a temperature scale from 200 degrees C to 1085 degrees C at the National Institute of Metrology of China. The construction and calibration of the IRT with the four fixed-point blackbodies are described. Characteristics of the IRT, such as the size-of-source effect, the amplifier performance and its stability are determined. The design of the four fixed-points, with 10 mm diameter of aperture and 0.9999 emissivity, is described. The uncertainty of the scale realization is elaborated.
引用
收藏
页码:643 / 648
页数:6
相关论文
共 10 条
  • [1] Fixed-point blackbodies at NIM
    Yuan, Z
    Duan, Y
    Wang, T
    SICE 2004 ANNUAL CONFERENCE, VOLS 1-3, 2004, : 1114 - 1117
  • [2] Accurate numerical model for characteristic temperature acquisition of miniature fixed-point blackbodies
    Sima, Rui-Heng
    Hao, Xiao-Peng
    Song, Jian
    Qi, Hong
    Yuan, Zun-Dong
    MEASUREMENT, 2021, 168
  • [3] Realization of a radiation temperature scale from 0 °C to 232 °C by a thermal infrared thermometer based on a multiple-fixed-point technique
    Yoo, Yong Shim
    Kim, Bong-Hak
    Lim, Sun Do
    Park, Seung-Nam
    Park, Seongchong
    METROLOGIA, 2013, 50 (04) : 409 - 416
  • [4] Development and Realization of Fe-C and Co-C Eutectic Fixed-Point Blackbodies for Radiation Thermometry at CSIR-NPL
    Pant, Umesh
    Meena, Hansraj
    Gupta, Gaurav
    Bapna, Komal
    Shivagan, D. D.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2020, 41 (07)
  • [5] Realization of radiance temperature scale from 500K to 1,250K by a radiation thermometer with a thermal detector
    Park, Seung-Nam
    Kim, Bong-Hak
    Park, Chul-Woung
    Lee, Dong-Hoon
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2008, 29 (01) : 301 - 311
  • [6] Realization of Radiance Temperature Scale from 500K to 1,250K by a Radiation Thermometer with a Thermal Detector
    Seung-Nam Park
    Bong-Hak Kim
    Chul-Woung Park
    Dong-Hoon Lee
    International Journal of Thermophysics, 2008, 29 : 301 - 311
  • [7] A triple point of water cell-based fixed-point blackbody for radiation thermometry
    Yurtseven, Semih
    Uytun, Ali
    Nasibov, Humbat
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2023, 34 (03)
  • [8] Comparison of a Detector-Based Near-IR Radiance Scale to an ITS-90 Calibrated Radiation Thermometer
    Eppeldauer, G. P.
    Yoon, H. W.
    Zeng, J.
    Larason, T. C.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2011, 32 (11-12) : 2197 - 2205
  • [9] Comparison of a Detector-Based Near-IR Radiance Scale to an ITS-90 Calibrated Radiation Thermometer
    G. P. Eppeldauer
    H. W. Yoon
    J. Zeng
    T. C. Larason
    International Journal of Thermophysics, 2011, 32 : 2197 - 2205
  • [10] Fixed-point implementation of interpolation-based MMSE MIMO detector in joint transmission scenario for LTE-A wireless standard
    Faraji, Sayed Rasoul
    Salari, Amin
    Sheikhaei, Samad
    AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS, 2016, 70 (11) : 1506 - 1514