Optimization of a flow injection differential potentiometric system with two identical electrodes for the determination of calcium ion in water with improved sensitivity

被引:6
作者
AlvaresRibeiro, LMBC
Machado, AASC
机构
[1] LAQUIPAI, Faculdade de Ciências, P4150 Porto
关键词
differential potentiometric detection; flow injection analysis; differential signal; modified simplex optimization; flow-through calcium electrodes; calcium in water;
D O I
10.1039/a703638h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An experimental optimization by the modified simplex method of a flow injection analysis (FIA) system for the differential potentiometric determination of calcium ion in mater is reported, The performances of the optimized system and of an equivalent conventional potentiometric FIA system are compared, The most important features of the proposed system are a substantial increase in sensitivity (from about 28 to shout 50 mV per decade) in the linear response range (10(-4) - 10(-2) mol l(-1) in both cases) and better repeatability (0.5 and 0.8% versus 1.7 and 1.9%, respectively, at 1 x 10(-3) and 6.2 x 10(-4) mol l(-1) calcium ion), The influence of the ionic strength is discussed, showing that it significantly affects the accuracy of the results. The relative accuracy of the differential system was demonstrated try the determination of the calcium content of drinking Waters in parallel with an ASTM certified method.
引用
收藏
页码:1435 / 1443
页数:9
相关论文
共 26 条
[1]   DESIGN AND EVALUATION OF MODIFIED SIMPLEX METHODS [J].
ABERG, ER ;
GUSTAVSSON, AGT .
ANALYTICA CHIMICA ACTA, 1982, 144 (DEC) :39-53
[2]  
ALONSO J, 1987, ANAL LETT, V20, P1247
[3]   SEQUENTIAL FLOW-INJECTION DETERMINATIONS OF CALCIUM AND MAGNESIUM IN WATERS [J].
ALONSO, J ;
BARTROLI, J ;
LIMA, JLFC ;
MACHADO, AASC .
ANALYTICA CHIMICA ACTA, 1986, 179 :503-508
[4]  
ALONSO J, 1988, J CHEMOMETR, V3, P249
[5]   COMPARISON OF THE SIMPLEX AND POWELL METHODS WITH A WEIGHTED RESPONSE FUNCTION FOR THE OPTIMIZATION OF FIA SYSTEMS [J].
ALVARESRIBEIRO, LMBC ;
MACHADO, AASC ;
ALONSO, J ;
BARTROLI, J ;
DELVALLE, M .
TALANTA, 1993, 40 (07) :1113-1126
[6]  
*ASTM, 1989, ANN BOOK ASTM STAND, P313
[7]  
BETTERIDGE D, 1985, TALANTA, V12, P723
[8]   FLOW-INJECTION ANALYSIS WITH ELECTROCHEMICAL DETECTION [J].
CAMMANN, K .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 329 (06) :691-697
[9]  
COUTO CM, 1994, 8 ENC LUS GAL QUIM V
[10]   DETERMINATION OF IONIC SURFACTANTS BY FLOW-INJECTION PSEUDOTITRATION [J].
DOWLE, CJ ;
COOKSEY, BG ;
OTTAWAY, JM ;
CAMPBELL, WC .
ANALYST, 1988, 113 (01) :117-119