Monitoring chloride ion penetration in concrete with different mineral admixtures based on embedded chloride ion selective electrodes

被引:36
作者
Jin, Ming [1 ]
Jiang, Linhua [1 ,2 ,3 ]
Zhu, Qiao [1 ]
机构
[1] Hohai Univ, Coll Mech & Mat, Nanjing 210098, Jiangsu, Peoples R China
[2] Engn Res Ctr New Mat & Protect Hydraul, 1 Xikang Rd, Nanjing 210098, Jiangsu, Peoples R China
[3] Natl Engn Res Ctr Water Resources Efficient Utili, Nanjing, Jiangsu, Peoples R China
关键词
Ag/AgCI; Electrode; Concrete; Chloride; Monitor; AG/AGCL REFERENCE ELECTRODE; CEMENT-BASED MATERIALS; DRYING-WETTING CYCLES; REINFORCED-CONCRETE; FLY-ASH; ELECTROCHEMICAL CHARACTERIZATION; MARINE-ENVIRONMENT; BINDING-CAPACITY; PORTLAND-CEMENT; CORROSION RISK;
D O I
10.1016/j.conbuildmat.2017.03.131
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper the development of free Cl- content in various types of concrete was monitored by means of the embedded AgiAgCl electrode. Moreover, the bound as well as total Cl- contents were determined through volumetric method. Besides, these mechanisms about the Cl-. diffusion in different types of concrete are analyzed and discussed. Results revealed that real-time monitoring of free Cl- concentration in concrete was achieved based on the measurements of potentials of embedded electrodes and the diffusion law of free Cl- content followed Fick's second law. In addition, the Freundlich isotherm was recommended to describe these relationships between free Cl- content and bound as well as total Cl- concentrations. As for the types of concrete with the addition of mineral admixture, lower total porosity and larger locked porosity have been found out. However, much more efforts should be paid to develop low-cost, robustness and long-term reliable Cl- selective sensors in order to achieve the wide application in concrete environment. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 15
页数:15
相关论文
共 53 条
  • [1] Analysis of the variability of chloride threshold values in the literature
    Alonso, M. C.
    Sanchez, M.
    [J]. MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2009, 60 (08): : 631 - 637
  • [2] Diffusion potentials in porous mortar in a moisture state below saturation
    Angst, Ueli
    Elsener, Bernhard
    Myrdal, Roar
    Vennesland, Oystein
    [J]. ELECTROCHIMICA ACTA, 2010, 55 (28) : 8545 - 8555
  • [3] Potentiometric determination of the chloride ion activity in cement based materials
    Angst, Ueli
    Elsener, Bernhard
    Larsen, Claus K.
    Vennesland, Oystein
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (03) : 561 - 573
  • [4] Chloride threshold level for corrosion of steel in concrete
    Ann, Ki Yong
    Song, Ha-Won
    [J]. CORROSION SCIENCE, 2007, 49 (11) : 4113 - 4133
  • [5] [Anonymous], 1990, Cement and Concrete Research, DOI [DOI 10.1016/0008-8846(90)90083-A, 10.1016/0008-8846(90)90083-A]
  • [6] [Anonymous], 2004, STAND TEST METH AC S
  • [7] [Anonymous], 2008, STAND TEST METH WAT
  • [8] Sources of error in using silver/silver chloride electrodes to monitor chloride activity in concrete
    Atkins, CP
    Carter, MA
    Scantlebury, JD
    [J]. CEMENT AND CONCRETE RESEARCH, 2001, 31 (08) : 1207 - 1211
  • [9] Monitoring chloride concentrations in hardened cement pastes using ion selective electrodes
    Atkins, CP
    Scantlebury, JD
    Nedwell, PJ
    Blatch, SP
    [J]. CEMENT AND CONCRETE RESEARCH, 1996, 26 (02) : 319 - 324
  • [10] Stochastic improvement of inspection and maintenance of corroding reinforced concrete structures placed in unsaturated environments
    Bastidas-Arteaga, Emilio
    Schoefs, Franck
    [J]. ENGINEERING STRUCTURES, 2012, 41 : 50 - 62