Loss of high-affinity thrombin receptors during platelet concentrate storage impairs the reactivity of platelets to thrombin

被引:50
作者
Lozano, ML
Rivera, J
GonzalezConejero, R
Moraleda, JM
Vicente, V
机构
[1] HOSP GEN UNIV MURCIA, SCH MED, CTR REG HEMODONAC, UNIT HEMATOOL & HEMOTHERAPY, MURCIA 30003, SPAIN
[2] UNIV MURCIA, DEPT INTERNAL MED, MURCIA, SPAIN
关键词
D O I
10.1046/j.1537-2995.1997.37497265336.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The storage of platelet concentrates (PCs) induces a reduction in the platelet surface expression of glycoprotein (GP) Iba. The location of the platelets' high-affinity binding site for thrombin has been postulated as being located on GPIb alpha. This study attempts to determine whether loss or alteration of GPIb alpha during storage of PCs is related to impairment in the reactivity of platelets to thrombin. STUDY DESIGN AND METHODS: In this study, platelet surface expression of GPIb alpha was monitored by means of flow cytometry, throughout standard storage of PCs for up to IO days. Two thrombin-induced platelet responses, the binding of radiolabeled fibrinogen and the platelet surface expression of P-selectin, were evaluated. Thrombin-binding assays were also performed to assess the number of thrombin receptors in platelets. RESULTS: The surface expression of the GPIb/IX complex declines during storage of PCs. The thrombin-induced maximal binding of fibrinogen in platelets stored for 3, 7, and 10 days was 77 +/- 7 percent, 60 +/- 20 percent, and 34 +/- 25 percent, respectively, of that found in fresh platelets. Moreover, the concentration of thrombin needed for 50 percent of platelets to express the CD62 antigen P-selectin at the surface increased from 0.05 U per mL in fresh platelets to 0.11, 0.56, and 1.2 U per mL in platelets stored for 3, 7, and 10 days, respectively. Thrombin-binding experiments demonstrated a significant reduction in the number of high-affinity binding sites throughout storage of PCs (55 +/- 21 sites/platelet in 10-day-stored platelets vs. 73 +/- 25 in fresh platelets). A significant correlation was also observed between the number of high-affinity thrombin-binding sites and surface expression of GPIb alpha. Selective blockage of the thrombin-binding site on GPIb alpha with monoclonal antibody LJ-Ib10 also inhibited the response of fresh platelets to thrombin, up to a level equivalent to that found in 3-day-stored platelets. CONCLUSION: The loss of the GPIb alpha-located high-affinity thrombin-binding site may impair the ability of platelets to become activated by thrombin as storage time increases.
引用
收藏
页码:368 / 375
页数:8
相关论文
共 48 条
[1]  
ADELMAN B, 1992, METHOD ENZYMOL, V215, P420
[2]   THROMBIN INTERACTIONS WITH PLATELET MEMBRANE-PROTEINS [J].
BERNDT, MC ;
GREGORY, C ;
DOWDEN, G ;
CASTALDI, PA .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1986, 485 :374-386
[3]   MONITORING THE RELEASE OF GLYCOCALICIN IN PLATELET CONCENTRATES BY ELISA [J].
BESSOS, H ;
MURPHY, WG ;
SEGHATCHIAN, MJ .
BLOOD COAGULATION & FIBRINOLYSIS, 1991, 2 (02) :373-376
[4]  
BODE AP, 1990, J LAB CLIN MED, V115, P667
[5]  
BRASS LF, 1992, J BIOL CHEM, V267, P13795
[6]   HYDROLYSIS OF HUMAN-PLATELET MEMBRANE-GLYCOPROTEINS WITH A SERRATIA-MARCESCENS METALLOPROTEASE - EFFECT ON RESPONSE TO THROMBIN AND VONWILLEBRAND-FACTOR [J].
COOPER, HA ;
BENNETT, WP ;
WHITE, GC ;
WAGNER, RH .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1982, 79 (05) :1433-1437
[7]   CHARACTERIZATION OF A FUNCTIONAL THROMBIN RECEPTOR - ISSUES AND OPPORTUNITIES [J].
COUGHLIN, SR ;
VU, TKH ;
HUNG, DT ;
WHEATON, VI .
JOURNAL OF CLINICAL INVESTIGATION, 1992, 89 (02) :351-355
[8]  
COUGHLIN SR, 1993, THROMB HAEMOSTASIS, V70, P184
[9]  
DEMARCO L, 1991, J BIOL CHEM, V266, P23776
[10]  
DEMARCO L, 1994, J BIOL CHEM, V269, P6478