Second-harmonic microscopy of unstained living cardiac myocytes: measurements of sarcomere length with 20-nm accuracy

被引:91
作者
Boulesteix, T [1 ]
Beaurepaire, E [1 ]
Sauviat, MP [1 ]
Schanne-Klein, MC [1 ]
机构
[1] Ecole Polytech, CNRS, INSERM, Lab Opt & Biosci, F-91128 Palaiseau, France
关键词
D O I
10.1364/OL.29.002031
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We extend second-harmonic generation (SHG) microscopy to the measurement of sarcomere length in unstained living cardiac myocytes with 20-nm accuracy. We quantify individual sarcomere shortening in the presence of saxitoxin and find that it is in agreement with mechanical measurements of atrial tissue contracture. This functional application of SHG microscopy is generally applicable to quantify the physiological effects of drugs on contractile tissue. Our data also suggest that packed myosin heads in sarcomere thick filaments are responsible for the large second-harmonic endogenous signal in muscle tissue. (C) 2004 Optical Society of America.
引用
收藏
页码:2031 / 2033
页数:3
相关论文
共 13 条
  • [1] Second harmonic generation imaging in muscle fibers
    Both, M
    Vogel, M
    Fink, RHA
    Uttenweiler, D
    [J]. CONFOCAL, MULTIPHOTON, AND NONLINEAR MICROSCOPIC IMAGING, 2003, 5139 : 112 - 120
  • [2] Force regulation by Ca2+ in skinned single cardiac myocytes of frog
    Brandt, PW
    Colomo, F
    Piroddi, N
    Poggesi, C
    Tesi, C
    [J]. BIOPHYSICAL JOURNAL, 1998, 74 (04) : 1994 - 2004
  • [3] High-resolution nonlinear optical imaging of live cells by second harmonic generation
    Campagnola, PJ
    Wei, MD
    Lewis, A
    Loew, LM
    [J]. BIOPHYSICAL JOURNAL, 1999, 77 (06) : 3341 - 3349
  • [4] Three-dimensional high-resolution second-harmonic generation imaging of endogenous structural proteins in biological tissues
    Campagnola, PJ
    Millard, AC
    Terasaki, M
    Hoppe, PE
    Malone, CJ
    Mohler, WA
    [J]. BIOPHYSICAL JOURNAL, 2002, 82 (01) : 493 - 508
  • [5] Real-time second-harmonic-generation microscopy based on a 2-GHz repetition rate Ti:sapphire laser
    Chu, SW
    Liu, TM
    Sun, CK
    [J]. OPTICS EXPRESS, 2003, 11 (08): : 933 - 938
  • [6] Second-harmonic tomography of tissues
    Guo, YC
    Ho, PP
    Savage, H
    Harris, D
    Sacks, P
    Schantz, S
    Liu, F
    Zhadin, N
    Alfano, RR
    [J]. OPTICS LETTERS, 1997, 22 (17) : 1323 - 1325
  • [7] Measurement of thin filament lengths by distributed deconvolution analysis of fluorescence images
    Littlefield, R
    Fowler, VM
    [J]. BIOPHYSICAL JOURNAL, 2002, 82 (05) : 2548 - 2564
  • [8] Membrane imaging by simultaneous second-harmonic generation and two-photon microscopy
    Moreaux, L
    Sandre, O
    Blanchard-Desce, M
    Mertz, J
    [J]. OPTICS LETTERS, 2000, 25 (05) : 320 - 322
  • [9] Narahashi T, 2000, J PHARMACOL EXP THER, V294, P1
  • [10] Sauviat Martin-Pierre, 2002, BMC Pharmacol, V2, P15, DOI 10.1186/1471-2210-2-15