Shaft speed ripples in wind turbines caused by tower shadow and wind shear

被引:26
作者
De Kooning, Jeroen D. M. [1 ]
Vandoorn, Tine L. [1 ]
Van de Vyver, Jan [1 ]
Meersman, Bart [1 ]
Vandevelde, Lieven [1 ]
机构
[1] Univ Ghent, Dept Elect Energy Syst & Automat EESA, Elect Energy Lab EELAB, B-9000 Ghent, Belgium
基金
比利时弗兰德研究基金会;
关键词
PERFORMANCE; GENERATOR; TURBULENCE; REDUCTION;
D O I
10.1049/iet-rpg.2013.0008
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Wind turbines are an important source of renewable energy. Although the amount of wind turbine installations has known a considerable increase in recent years, technological improvements are still needed to increase their efficiency. An important subject is the presence of vibrations. For instance, ripples can be present in the torque and shaft speed, which can be caused by turbulence of the air flow, resonance or mechanical problems. Furthermore, tower shadow and wind shear are able to cause significant torque oscillations. In literature, a mathematical model of the torque oscillations has been presented for three-bladed horizontal-axis upwind turbines. However, it remains unclear what the impact is of these torque oscillations on the shaft speed. When ripples are present in the shaft speed, they affect the back-electromotive force and electrical power of the generator and could propagate further in the system. Therefore this study investigates whether this effect is large enough to have a considerable impact on the system. The turbine inertia and size are both relevant parameters in this research. However, it will be shown by mathematical proof that the relative amount of shaft speed ripples caused by tower shadow and wind shear is independent of the turbine size.
引用
收藏
页码:195 / 202
页数:8
相关论文
共 20 条
[1]   Performance Assessment of Micro and Small-Scale Wind Turbines in Urban Areas [J].
Acosta, Jorge L. ;
Combe, Kevin ;
Djokic, Sasa Z. ;
Hernando-Gil, Ignacio .
IEEE SYSTEMS JOURNAL, 2012, 6 (01) :152-163
[2]   Axial-flux permanent-magnet air-cored generator for small-scale wind turbines [J].
Bumby, JR ;
Martin, R .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2005, 152 (05) :1065-1075
[3]   A Review of the State of the Art of Power Electronics for Wind Turbines [J].
Chen, Zhe ;
Guerrero, Josep M. ;
Blaabjerg, Frede .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (08) :1859-1875
[4]  
Dolan DSL, 2006, 2006 IEEE/PES POWER SYSTEMS CONFERENCE AND EXPOSITION. VOLS 1-5, P2050, DOI 10.1109/TEC.2006.874211
[5]   Magnetic field and vibration monitoring in permanent magnet synchronous motors under eccentricity fault [J].
Ebrahimi, B. M. ;
Faiz, J. .
IET ELECTRIC POWER APPLICATIONS, 2012, 6 (01) :35-45
[6]   The Impact of Tower Shadow, Yaw Error, and Wind Shears on Power Quality in a Wind-Diesel System [J].
Fadaeinedjad, Roohollah ;
Moschopoulos, Gerry ;
Moallem, Mehrdad .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2009, 24 (01) :102-111
[7]   Small-signal modelling and analysis of wind turbine with direct drive permanent magnet synchronous generator connected to power grid [J].
Huang, H. ;
Mao, C. ;
Lu, J. ;
Wang, D. .
IET RENEWABLE POWER GENERATION, 2012, 6 (01) :48-58
[8]   Influence of tower shadow and wind turbulence on the performance of power system stabilizers for DFIG-based wind farms [J].
Hughes, F. Michael ;
Anaya-Lara, Olimpo ;
Ramtharan, G. ;
Jenkins, Nicholas ;
Strbac, Goran .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2008, 23 (02) :519-528
[9]   Mechanical vibration reduction control of two-mass permanent magnet synchronous motor using adaptive notch filter with fast Fourier transform analysis [J].
Lee, D. -H. ;
Lee, J. H. ;
Ahn, J. -W. .
IET ELECTRIC POWER APPLICATIONS, 2012, 6 (07) :455-461
[10]   DEPENDENCE OF PERFORMANCE OF VARIABLE SPEED WIND TURBINES ON THE TURBULENCE, DYNAMICS AND CONTROL [J].
LEITHEAD, WE .
IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1990, 137 (06) :403-413