Subcutaneous Versus Transvenous Implantable Defibrillator Therapy: A Systematic Review and Meta-Analysis of Randomized Trials and Propensity Score-Matched Studies

被引:28
作者
Fong, Khi Yung [1 ]
Ng, Colin Jun Rong [2 ]
Wang, Yue [2 ]
Yeo, Colin [2 ]
Tan, Vern Hsen [2 ]
机构
[1] Natl Univ Singapore, Yong Loo Lin Sch Med, Singapore, Singapore
[2] Changi Gen HospitalSingapore, Dept Cardiol, Singapore, Singapore
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2022年 / 11卷 / 11期
关键词
cardiac arrythmias; implantable cardioverter-defibrillator; meta-analysis; CARDIOVERTER-DEFIBRILLATOR; ICD INCIDENCE; OUTCOMES; ASSOCIATION; PREVENTION; SURVIVAL; PREDICTORS; REGISTRY; SHOCKS;
D O I
10.1161/JAHA.121.024756
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Subcutaneous implantable cardioverter-defibrillators (S-ICDs) have been of great interest as an alternative to transvenous implantable cardioverter-defibrillators (TV-ICDs). No meta-analyses synthesizing data from high-quality studies have yet been published. Methods and Results An electronic literature search was conducted to retrieve randomized controlled trials or propensity score-matched studies comparing S-ICD against TV-ICD in patients with an implantable cardioverter-defibrillator indication. The primary outcomes were device-related complications and lead-related complications. Secondary outcomes were inappropriate shocks, appropriate shock, all-cause mortality, and infection. All outcomes were pooled under random-effects meta-analyses and reported as risk ratios (RRs) and 95% CIs. Kaplan-Meier curves of device-related complications were digitized to retrieve individual patient data and pooled under a 1-stage meta-analysis using Cox models to determine hazard ratios (HRs) of patients undergoing S-ICD versus TV-ICD. A total of 5 studies (2387 patients) were retrieved. S-ICD had a similar rate of device-related complications compared with TV-ICD (RR, 0.59 [95% CI, 0.33-1.04]; P=0.070), but a significantly lower lead-related complication rate (RR, 0.14 [95% CI, 0.07-0.29]; P<0.0001). The individual patient data-based 1-stage stratified Cox model for device-related complications across 4 studies yielded no significant difference (shared-frailty HR, 0.82 [95% CI, 0.61-1.09]; P=0.167), but visual inspection of pooled Kaplan-Meier curves suggested a divergence favoring S-ICD. Secondary outcomes did not differ significantly between both modalities. Conclusions S-ICD is clinically superior to TV-ICD in terms of lead-related complications while demonstrating comparable efficacy and safety. For device-related complications, S-ICD may be beneficial over TV-ICD in the long term. These indicate that S-ICD is likely a suitable substitute for TV-ICD in patients requiring implantable cardioverter-defibrillator implantation without a pacing indication.
引用
收藏
页数:18
相关论文
共 58 条
[11]   Canadian Registry of Electronic Device Outcomes (CREDO) : The Abbott ICD Premature Battery Depletion Advisory, a Multicentre Cohort Study [J].
Davis, Jason ;
Thibault, Bernard ;
Mangat, Iqwal ;
Coutu, Benoit ;
Bennett, Matthew ;
Philippon, Francois ;
Sandhu, Roopinder ;
Sterns, Laurence ;
Essebag, Vidal ;
Nery, Pablo ;
Wells, George ;
Yee, Raymond ;
Exner, Derek ;
Krahn, Andrew ;
Parkash, Ratika .
CJC OPEN, 2021, 3 (01) :48-53
[12]   Suitability for subcutaneous defibrillator implantation: results based on data from routine clinical practice [J].
de Bie, Mihaly K. ;
Thijssen, Joep ;
van Rees, Johannes B. ;
Putter, Hein ;
van der Velde, Enno T. ;
Schalij, Martin J. ;
van Erven, Lieselot .
HEART, 2013, 99 (14) :1018-1023
[13]   Drug Coated Balloons for Dysfunctional Haemodialysis Venous Access: A Patient Level Meta-Analysis of Randomised Controlled Trials [J].
Fong, Khi Yung ;
Zhao, Joseph J. ;
Tan, Eelin ;
Syn, Nicholas L. ;
Sultana, Rehena ;
Da Zhuang, Kun ;
Chua, Jasmine Ming Er ;
Patel, Ankur ;
Irani, Farah G. ;
Tay, Kiang Hiong ;
Tan, Bien Soo ;
Too, Chow Wei .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2021, 62 (04) :610-621
[14]   Primary Results From the Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction (UNTOUCHED) Trial [J].
Gold, Michael R. ;
Lambiase, Pier D. ;
El-Chami, Mikhael F. ;
Knops, Reinoud E. ;
Aasbo, Johan D. ;
Bongiorni, Maria Grazia ;
Russo, Andrea M. ;
Deharo, Jean-Claude ;
Burke, Martin C. ;
Dinerman, Jay ;
Barr, Craig S. ;
Shaik, Naushad ;
Carter, Nathan ;
Stoltz, Thomas ;
Stein, Kenneth M. ;
Brisben, Amy J. ;
Boersma, Lucas V. A. .
CIRCULATION, 2021, 143 (01) :7-17
[15]   Head-To-Head Comparison of Arrhythmia Discrimination Performance of Subcutaneous and Transvenous ICD Arrhythmia Detection Algorithms: The START Study [J].
Gold, Michael R. ;
Theuns, Dominic A. ;
Knight, Bradley P. ;
Sturdivant, J. Lacy ;
Sanghera, Rick ;
Ellenbogen, Kenneth A. ;
Wood, Mark A. ;
Burke, Martin C. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (04) :359-366
[16]  
GRAMBSCH PM, 1994, BIOMETRIKA, V81, P515
[17]   Use of an electrocardiographic screening tool to determine candidacy for a subcutaneous implantable cardioverter-defibrillator [J].
Groh, Christopher A. ;
Sharma, Shishir ;
Pelchovitz, Daniel J. ;
Bhave, Prashant D. ;
Rhyner, John ;
Verma, Nishant ;
Arora, Rishi ;
Chicos, Alexandru B. ;
Kim, Susan S. ;
Lin, Albert C. ;
Passman, Rod S. ;
Knight, Bradley P. .
HEART RHYTHM, 2014, 11 (08) :1361-1366
[18]   Enhanced secondary analysis of survival data: reconstructing the data from published Kaplan-Meier survival curves [J].
Guyot, Patricia ;
Ades, A. E. ;
Ouwens, Mario J. N. M. ;
Welton, Nicky J. .
BMC MEDICAL RESEARCH METHODOLOGY, 2012, 12
[19]   Measuring inconsistency in meta-analyses [J].
Higgins, JPT ;
Thompson, SG ;
Deeks, JJ ;
Altman, DG .
BMJ-BRITISH MEDICAL JOURNAL, 2003, 327 (7414) :557-560
[20]   Surgical Valvotomy Versus Balloon Valvuloplasty for Congenital Aortic Valve Stenosis: A Systematic Review and Meta-Analysis [J].
Hill, Garick D. ;
Ginde, Salil ;
Rios, Rodrigo ;
Frommelt, Peter C. ;
Hill, Kevin D. .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (08)