High-Sensitivity X-ray Fluorescence Analysis of Solutions with the Use of a Sorption Accumulation Microsystem

被引:5
作者
Khamizov, R. Kh. [1 ]
Gruzdeva, A. N. [1 ]
Tokmachev, M. G. [2 ]
Tsizin, G. I. [2 ]
Tikhonov, N. A. [2 ]
Kumakhov, M. A. [3 ]
机构
[1] Russian Acad Sci, VI Vernadskii Inst Geochem & Analyt Chem, Moscow 119991, Russia
[2] Moscow MV Lomonosov State Univ, Dept Chem, Moscow 119991, Russia
[3] Inst Xray Opt, Moscow 125315, Russia
关键词
PRECONCENTRATION;
D O I
10.1134/S106193480909007X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A mass-transfer kinetic model is proposed for an embedded sorption accumulation microsystem based on polycapillary structures to be used in the developed X-ray fluorescence analyzer with preconcentration. The model is used to substantiate a kinetic method for high-sensitivity X-ray fluorescence determination of elements in multicomponent solutions. With the use of this model, experimental data on X-ray fluorescence spectra are analyzed and kinetic and equilibrium parameters are found for the sorption of copper, nickel, manganese, iron, and zinc on the selective DETATA sorbent.
引用
收藏
页码:916 / 920
页数:5
相关论文
共 28 条
  • [1] Sorption of Se(IV) from Aqueous Solutions with Subsequent Determination by X-Ray Fluorescence Analysis
    Filatova, D. G.
    Arkhipenko, A. A.
    Statkus, M. A.
    Es'kina, V. V.
    Baranovskaya, V. B.
    Karpov, Yu A.
    INORGANIC MATERIALS, 2021, 57 (14) : 1427 - 1430
  • [2] Sorption of As(III) and Se(IV) from Aqueous Solutions for Subsequent Determination by Total Reflection X-Ray Fluorescence
    Filatova, D. G.
    Arkhipenko, A. A.
    Statkus, M. A.
    Mikheev, I. V.
    Baranovskaya, V. B.
    Karpov, Yu. A.
    INORGANIC MATERIALS, 2022, 58 (14) : 1435 - 1438
  • [3] Possibilities of micro X-ray fluorescence spectrometry of solutions with preconcentration
    A. A. Bolotokov
    A. N. Gruzdeva
    R. Kh. Khamizov
    M. A. Kumakhov
    Journal of Analytical Chemistry, 2014, 69 : 728 - 734
  • [4] Possibilities of micro X-ray fluorescence spectrometry of solutions with preconcentration
    Bolotokov, A. A.
    Gruzdeva, A. N.
    Khamizov, R. Kh.
    Kumakhov, M. A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 69 (08) : 728 - 734
  • [5] Preconcentration Methods for the Analysis of Liquid Samples by X-Ray Fluorescence Techniques
    Margui, E.
    Van Grieken, R.
    Fontas, C.
    Hidalgo, M.
    Queralt, I.
    APPLIED SPECTROSCOPY REVIEWS, 2010, 45 (03) : 179 - 205
  • [6] Trace and ultratrace analysis of liquid samples by X-ray fluorescence spectrometry
    Margui, E.
    Zawisza, B.
    Sitko, R.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 53 : 73 - 83
  • [7] Improved instrumental sensitivity for Cd determination in aqueous solutions using Wavelength Dispersive X-ray Fluorescence Spectrometry, Rh-target tube instrumentation
    Margui, Eva
    Fontas, Claudia
    Hidalgo, Manuela
    Queralt, Ignacio
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (11) : 1329 - 1332
  • [8] Total reflection X-ray fluorescence analysis of trace elements in Bulgarian bottled mineral waters of low and high mineral content
    Georgieva, Ralitsa
    Detcheva, Albena
    Karadjov, Methody
    Jordanov, Juri
    Ivanova, Elisaveta
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2013, 93 (10) : 1043 - 1051
  • [9] Total Reflection X-ray Fluorescence Spectrometric Analysis of Ten Lanthanides at the Ultratrace Level Having a High Degree of Overlap in the Emission Lines
    Sanyal, Kaushik
    Saha, Abhijit
    Sarkar, Arnab
    Deb, Sadhan Bijoy
    Pai, Rajesh V.
    Saxena, Manoj Kumar
    ACS OMEGA, 2023, 8 (44): : 41402 - 41410
  • [10] Radionuclide X-ray fluorescence analysis of selected elements in drug samples with 8-hydroxyquinoline preconcentration
    Mikusova, V.
    Lukacovicova, O.
    Havranek, E.
    Mikus, P.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 299 (03) : 1645 - 1652