Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons

被引:46
作者
Ballester, Facundo [1 ,2 ]
Granero, Domingo [3 ]
Perez-Calatayud, Jose [4 ]
Melhus, Christopher S. [5 ]
Rivard, Mark J. [5 ]
机构
[1] Univ Valencia, Dept Atom Mol & Nucl Phys, E-46100 Burjassot, Spain
[2] Univ Valencia, CSIC, IFIC, E-46100 Burjassot, Spain
[3] Hosp Gen Univ, ERESA, Dept Radiat Phys, E-46014 Valencia, Spain
[4] La Fe Univ Hosp, Dept Radiat Oncol, E-46009 Valencia, Spain
[5] Tufts Univ, Sch Med, Dept Radiat Oncol, Boston, MA 02111 USA
关键词
Monte Carlo; brachytherapy; electronic disequilibrium; dosimetry; GEANT4; PENELOPE; MONTE-CARLO; DOSIMETRY PARAMETERS; PHOTON TRANSPORT; RATE CONSTANT; IR-192; CS-137; POINT; BETA; CODE;
D O I
10.1118/1.3194754
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The region of electronic disequilibrium near photon-emitting brachytherapy sources of high-energy radionuclides (Co-60, Cs-137, Ir-192, and Yb-169) and contributions to total dose from emitted electrons were studied using the GEANT4 and PENELOPE Monte Carlo codes. Methods: Hypothetical sources with active and capsule materials mimicking those of actual sources but with spherical shape were examined. Dose contributions due to source photons, x rays, and bremsstrahlung; source beta(-), Auger electrons, and internal conversion electrons; and water collisional kerma were scored. To determine if conclusions obtained for electronic equilibrium conditions and electron dose contribution to total dose for the representative spherical sources could be applied to actual sources, the Ir-192 mHDR-v2 source model (Nucletron B.V., Veenendaal, The Netherlands) was simulated for comparison to spherical source results and to published data. Results: Electronic equilibrium within 1% is reached for Co-60, Cs-137, Ir-192, and Yb-169 at distances greater than 7, 3.5, 2, and 1 mm from the source center, respectively, in agreement with other published studies. At 1 mm from the source center, the electron contributions to total dose are 1.9% and 9.4% for Co-60 and Ir-192, respectively. Electron emissions become important (i.e., >0.5%) within 3.3 mm of Co-60 and 1.7 mm of Ir-192 sources, yet are negligible over all distances for Cs-137 and Yb-169. Electronic equilibrium conditions along the transversal source axis for the mHDR-v2 source are comparable to those of the spherical sources while electron dose to total dose contribution are quite different. Conclusions: Electronic equilibrium conditions obtained for spherical sources could be generalized to actual sources while electron contribution to total dose depends strongly on source dimensions, material composition, and electron spectra. (C) 2009 American Association of Physicists in Medicine. [DOI: 10.1118/1.3194754]
引用
收藏
页码:4250 / 4256
页数:7
相关论文
共 33 条
  • [1] GEANT4-a simulation toolkit
    Agostinelli, S
    Allison, J
    Amako, K
    Apostolakis, J
    Araujo, H
    Arce, P
    Asai, M
    Axen, D
    Banerjee, S
    Barrand, G
    Behner, F
    Bellagamba, L
    Boudreau, J
    Broglia, L
    Brunengo, A
    Burkhardt, H
    Chauvie, S
    Chuma, J
    Chytracek, R
    Cooperman, G
    Cosmo, G
    Degtyarenko, P
    Dell'Acqua, A
    Depaola, G
    Dietrich, D
    Enami, R
    Feliciello, A
    Ferguson, C
    Fesefeldt, H
    Folger, G
    Foppiano, F
    Forti, A
    Garelli, S
    Giani, S
    Giannitrapani, R
    Gibin, D
    Cadenas, JJG
    González, I
    Abril, GG
    Greeniaus, G
    Greiner, W
    Grichine, V
    Grossheim, A
    Guatelli, S
    Gumplinger, P
    Hamatsu, R
    Hashimoto, K
    Hasui, H
    Heikkinen, A
    Howard, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) : 250 - 303
  • [2] Characterization of a high-dose-rate 90Sr-90Y source for intravascular brachytherapy by using the Monte Carlo code PENELOPE
    Asenjo, J
    Fernández-Varea, JM
    Sánchez-Reyes, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (05) : 697 - 711
  • [3] Beta versus gamma dosimetry close to Ir-192 brachytherapy sources
    Baltas, D
    Karaiskos, P
    Papagiannis, P
    Sakelliou, L
    Loeffler, E
    Zamboglou, N
    [J]. MEDICAL PHYSICS, 2001, 28 (09) : 1875 - 1882
  • [4] Dose rate constant and energy spectrum of interstitial brachytherapy sources
    Chen, Z
    Nath, R
    [J]. MEDICAL PHYSICS, 2001, 28 (01) : 86 - 96
  • [5] Verification of Ir-192 near source dosimetry using GAFCHROMIC® film
    Chiu-Tsao, ST
    Duckworth, TL
    Patel, NS
    Pisch, J
    Harrison, LB
    [J]. MEDICAL PHYSICS, 2004, 31 (02) : 201 - 207
  • [6] CULLEN DE, 2001, UCRL50400 LAWR LIV N
  • [7] Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source
    Daskalov, GM
    Loffler, E
    Williamson, JF
    [J]. MEDICAL PHYSICS, 1998, 25 (11) : 2200 - 2208
  • [8] Eckerman K, 2008, Ann ICRP, V38, P7, DOI [10.1016/j.icrp.2009.02.001, 10.1016/j.icrp.2008.10.004]
  • [9] Toward endobronchial Ir-192 high-dose-rate brachytherapy therapeutic optimization
    Gay, H. A.
    Allison, R. R.
    Downie, G. H.
    Mota, H. C.
    Austerlitz, C.
    Jenkins, T.
    Sibata, C. H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (11) : 2987 - 2999
  • [10] *GEANT4, GEANT4 PHYS MAN