A Robust Beat-to-Beat Artifact Detection Algorithm for Pulse Wave

被引:1
|
作者
Hu, Qihan [1 ]
Deng, Xintao [2 ]
Liu, Xin [1 ]
Wang, Aiguo [2 ]
Yang, Cuiwei [1 ,3 ]
机构
[1] Fudan Univ, Dept Elect Engn, Shanghai 200433, Peoples R China
[2] Xinghua City Peoples Hosp, Dept Cardiol, Changzhou 225700, Jiangsu, Peoples R China
[3] Shanghai Engn Res Ctr Cardiac Electrophysiol, Key Lab Med Imaging Comp & Comp Assisted Interven, Shanghai 201318, Peoples R China
基金
中国国家自然科学基金;
关键词
CANCELLATION;
D O I
10.1155/2020/5691805
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
With the rise of the concept of smart cities and healthcare, artificial intelligence helps people pay increasing attention to the health of themselves. People can wear a variety of wearable devices to monitor their physiological conditions. The pulse wave is a kind of physiological signal which is widely applied in the physiological monitoring system. However, the pulse wave is susceptible to artifacts, which prevents its popularization. In this work, we propose a novel beat-to-beat artifact detection algorithm, which performs pulse wave segmentation based on wavelet transform and then detects artifacts beat by beat based on the decision list. We verified our method on data acquired from different databases and compared with experts' annotations. The segmentation algorithm achieved an accuracy of 96.13%. When it is applied to detect main peaks, the performance achieved an accuracy of 99.11%. After the previous segmentation algorithm, the artifact detection algorithm can detect beat-to-beat pulse waves and artifacts with an accuracy of 98.11%. The result indicated that the proposed method is robust for pulse waves of different patterns and could effectively detect the artifact without the complex algorithm. In summary, our proposed algorithm is capable of annotating pulse waves of various patterns and determining pulse wave quality. Since our method is developed and evaluated on the transmission-mode PPG data, it is more suitable for the devices and applications inside the hospitals instead of reflectance-mode PPG.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Beat-to-beat variability of pulse wave velocity
    Svacinova, J.
    Hidegova, S.
    Sieglova, H.
    Kascakova, Z.
    Fabsik, M.
    Jakubik, J.
    Novak, J.
    Novakova, Z.
    Hruskova, H.
    ACTA PHYSIOLOGICA, 2019, 227 : 161 - 161
  • [2] ROBUST BEAT-TO-BEAT DETECTION ALGORITHM FOR PULSE RATE VARIABILITY ANALYSIS FROM WRIST PHOTOPLETHYSMOGRAPHY SIGNALS
    Foroozan, Foroohar
    Mohan, Madhan
    Wu, Jian Shu
    2018 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2018, : 2136 - 2140
  • [3] Beat-to-beat noninvasive hemodynamics and pulse wave velocity
    Malnaric, V.
    Ferjan, S.
    Brguljan, J.
    Salobir, B.
    Accetto, R.
    JOURNAL OF HYPERTENSION, 2008, 26 : S506 - S506
  • [4] Beat-to-beat oscillations in pulse pressure
    Virtanen, R
    Jula, A
    Kuusela, T
    Airaksinen, J
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2004, 24 (05) : 304 - 309
  • [5] Feasibility of Brachial Occlusion Technique for Beat-to-Beat Pulse Wave Analysis
    Matera, Lukas
    Sajgalik, Pavol
    Fabian, Vratislav
    Mikhailov, Yegor
    Zemanek, David
    Johnson, Bruce D.
    SENSORS, 2022, 22 (19)
  • [6] Beat-to-Beat Variation in Pulse Wave Velocity During Breathing Maneuvers
    Gaddum, Nicholas R.
    Schaeffter, Tobias
    Buehrer, Martin
    Rutten, Marcel
    Smith, Lorna
    Chowienczyk, Philip J.
    Beerbaum, Philipp B. J.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (01) : 202 - 210
  • [7] BEAT-TO-BEAT VARIABILITY OF INVASIVE PULSE WAVE VELOCITY: TECHNICAL AND CLINICAL ASPECTS
    Giudici, Alessandro
    Grillo, Andrea
    Scalise, Filippo
    Reesink, Koen D.
    Delhaas, Tammo
    Salvi, Paolo
    Parati, Gianfranco
    Spronck, Bart
    JOURNAL OF HYPERTENSION, 2023, 41 : E58 - E59
  • [8] CAROTID-FEMORAL PULSE WAVE VELOCITY VARIABILITY: BEAT-TO-BEAT ASSESSMENT
    Obeid, Hasan
    Tairi, Amira
    Fortier, Catherine
    Giudici, Alessandro
    Spronck, Bart
    Agharazii, Mohsen
    JOURNAL OF HYPERTENSION, 2023, 41 : E268 - E268
  • [9] Unexpected sawtooth artifact in beat-to-beat pulse transit time measured from patient monitor data
    Lin, Yu-Ting
    Lo, Yu-Lun
    Lin, Chen-Yun
    Frasch, Martin G.
    Wu, Hau-Tieng
    PLOS ONE, 2019, 14 (09):
  • [10] Beat-to-beat variability of aortic pulse wave velocity: implications for aortic stiffness measurements
    Giudici, Alessandro
    Grillo, Andrea
    Scalise, Filippo
    Reesink, Koen D.
    Delhaas, Tammo
    Salvi, Paolo
    Spronck, Bart
    Parati, Gianfranco
    JOURNAL OF HYPERTENSION, 2025, 43 (04) : 589 - 597