Simultaneous determination of dopamine and cysteamine by flow injection with multiple pulse amperometric detection using a boron-doped diamond electrode

被引:24
作者
Wong, Ademar [1 ]
Santos, Anderson Martin [1 ]
Fatibello-Filho, Orlando [1 ]
机构
[1] Univ Fed Sao Carlos, Dept Chem, POB 676, BR-13560970 Sao Carlos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Dopamine; Cysteamine; FIA; Simultaneous determination; Boron-doped diamond; CAPILLARY-ELECTROPHORESIS; ELECTROCHEMICAL SENSOR; PASTE ELECTRODE; ASCORBIC-ACID; QUANTUM DOTS; PERFORMANCE; GRAPHENE; EPINEPHRINE; SAMPLES;
D O I
10.1016/j.diamond.2018.03.034
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A flow injection analysis (FIA) system with multiple pulse amperometric (MPA) detection was proposed for the simultaneous determination of dopamine (DOP) and cysteamine (CYS) using a cathodically pre-treated boron-doped diamond electrode (CPT-BDD). The electrochemical behaviors of DOP and CYS were evaluated by cyclic voltammetry in a potential range from 0 to 1.7 V at a scan rate of 0.05 V s(-1) using 0.05 mol L-1 H2SO4 as supporting electrolyte. Two oxidation peaks were observed during anodic potential scanning, at potentials of 0.8 V (DOP) and 1.6 V (CYS). Under optimized experimental conditions, such as potentials E-1 = + 0.8 V 100 ms(-1) (pulse potential at which DOP was oxidized) and E-2 = + 1.6 V 200 ms(-1) (pulse potential at which both analytes were oxidized), the analytical curves were linear in the concentration ranges from 5.0 x 10(-7) to 1.3 x 10(-4) mol L-1 for DOP and from 5.0 x 10(-7) to 1.5 x 10(-4) mol for CYS, with detection limits of 1.1 x 10(-8) and 1.3 x 10(-8) mol L-1, respectively. The BDD sensor showed good sensitivity, stability and repeatability (analytical frequency of 165 determinations per hour), and no interference in the electrochemical determination of these analytes in the presence of other compounds. The proposed method was successfully applied using the FIA-MPA method in river water and serum samples, with recoveries close to 100%.
引用
收藏
页码:68 / 73
页数:6
相关论文
共 38 条
  • [1] WO3 nanoparticles based direct electrochemical dopamine sensor in the presence of ascorbic acid
    Anithaa, A. C.
    Lavanya, N.
    Asokan, K.
    Sekar, C.
    [J]. ELECTROCHIMICA ACTA, 2015, 167 : 294 - 302
  • [2] Determination of cysteamine using label-free gold nanoparticles
    Apyari, Vladimir V.
    Dmitrienko, Stanislava G.
    Arkhipova, Viktoriya V.
    Atnagulov, Aydar G.
    Zolotov, Yuri A.
    [J]. ANALYTICAL METHODS, 2012, 4 (10) : 3193 - 3199
  • [3] Electrochemical determination of cysteamine in the presence of guanine and adenine using a carbon paste electrode modified with N-(4-hydroxyphenyl)-3,5-dinitrobenzamide and magnesium oxide nanoparticles
    Arabali, Vahid
    Karimi-Maleh, Hassan
    [J]. ANALYTICAL METHODS, 2016, 8 (28) : 5604 - 5610
  • [4] Cysteamine capped CdS quantum dots as a fluorescence sensor for the determination of copper ion exploiting fluorescence enhancement and long-wave spectral shifts
    Boonmee, Chanida
    Noipa, Tuanjai
    Tuntulani, Thawatchai
    Ngeontae, Wittaya
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2016, 169 : 161 - 168
  • [5] High performance electrochemical sensors for dopamine and epinephrine using nanocrystalline carbon quantum dots obtained under controlled chronoamperometric conditions
    Canevari, Thiago C.
    Nakamura, Marcelo
    Cincotto, Fernando H.
    de Melo, Fernando M.
    Toma, Henrique E.
    [J]. ELECTROCHIMICA ACTA, 2016, 209 : 464 - 470
  • [6] Capillary electrophoresis method development for determination of impurities in sodium cysteamine phosphate samples
    Carvalho, Alexandre Zatkovskis
    Pauwels, Jochen
    De Greef, Bart
    Vynckier, An-Katrien
    Wen Yuqi
    Hoogmartens, Jos
    Van Schepdael, Ann
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 42 (01) : 120 - 125
  • [7] Electrochemical dopamine sensor based on P-doped graphene: Highly active metal-free catalyst and metal catalyst support
    Chu, Ke
    Wang, Fan
    Zhao, Xiao-lin
    Wang, Xin-wei
    Tian, Ye
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 81 : 452 - 458
  • [8] Quantitation of dopamine, serotonin and adenosine content in a tissue punch from a brain slice using capillary electrophoresis with fast-scan cyclic voltammetry detection
    Fang, Huaifang
    Pajski, Megan L.
    Ross, Ashley E.
    Venton, B. Jill
    [J]. ANALYTICAL METHODS, 2013, 5 (11) : 2704 - 2711
  • [9] Gandini D, 1999, NEW DIAM FRONT C TEC, V9, P303
  • [10] Spectrophotometric Determination of Dopamine Hydrochloride in Pharmaceutical, Banana, Urine and Serum Samples by Potassium Ferricyanide-Fe(III)
    Guo, Li
    Zhang, Yan
    Li, Quanmin