Fast optimization and dose calculation in scanned ion beam therapy

被引:7
作者
Hild, S. [1 ,2 ,3 ,4 ]
Graeff, C. [5 ]
Trautmann, J. [5 ]
Kraemer, M. [5 ]
Zink, K. [4 ,6 ]
Durante, M. [5 ,7 ]
Bert, C. [2 ,3 ,5 ]
机构
[1] GSI Helmholtzzentrum Schwerionenforsch GmbH, Dept Biophys, D-64291 Darmstadt, Germany
[2] Univ Clin Erlangen, Dept Radiat Oncol, D-91054 Erlangen, Germany
[3] Friedrich Alexander Univ Erlangen Nurnberg FAU, D-91054 Erlangen, Germany
[4] Univ Appl Sci, Inst Med Phys & Radiat Protect, D-35390 Giessen, Germany
[5] GSI Helmholtzzentrum Schwerionenforsch GmbH, Dept Biophys, D-64289 Darmstadt, Germany
[6] Univ Hosp Giessen Marburg, Dept Radiotherapy & Radiooncol, D-35043 Marburg, Germany
[7] Tech Univ Darmstadt, Fac Phys, D-64289 Darmstadt, Germany
关键词
particle therapy; prostate cancer; adaptive treatment planning; fast dose calculation; RADIOTHERAPY; SYSTEM; CT; DESIGN; TUMORS; MODEL;
D O I
10.1118/1.4881522
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Particle therapy (PT) has advantages over photon irradiation on static tumors. An increased biological effectiveness and active target conformal dose shaping are strong arguments for PT. However, the sensitivity to changes of internal geometry complicates the use of PT for moving organs. In case of interfractionally moving objects adaptive radiotherapy (ART) concepts known from intensity modulated radiotherapy (IMRT) can be adopted for PT treatments. One ART strategy is to optimize a new treatment plan based on daily image data directly before a radiation fraction is delivered [treatment replanning (TRP)]. Optimizing treatment plans for PT using a scanned beam is a time consuming problem especially for particles other than protons where the biological effective dose has to be calculated. For the purpose of TRP, fast optimization and fast dose calculation have been implemented into the GSI in-house treatment planning system (TPS) TRiP98. Methods: This work reports about the outcome of a code analysis that resulted in optimization of the calculation processes as well as implementation of routines supporting parallel execution of the code. To benchmark the new features, the calculation time for therapy treatment planning has been studied. Results: Compared to the original version of the TPS, calculation times for treatment planning (optimization and dose calculation) have been improved by a factor of 10 with code optimization. The parallelization of the TPS resulted in a speedup factor of 12 and 5.5 for the original version and the code optimized version, respectively. Hence the total speedup of the new implementation of the authors' TPS yielded speedup factors up to 55. Conclusions: The improved TPS is capable of completing treatment planning for ion beam therapy of a prostate irradiation considering organs at risk in this has been overseen in the review process. Also see below 6 min. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Gating window dependency on scanned carbon-ion beam dose distribution and imaging dose for thoracoabdominal treatment
    Mori, Shinichiro
    Karube, Masataka
    Yasuda, Shigeo
    Yamamoto, Naoyoshi
    Tsuji, Hiroshi
    Kamada, Tadashi
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1074)
  • [22] A novel algorithm for the calculation of physical and biological irradiation quantities in scanned ion beam therapy: the beamlet superposition approach
    Russo, G.
    Attili, A.
    Battistoni, G.
    Bertrand, D.
    Bourhaleb, F.
    Cappucci, F.
    Ciocca, M.
    Mairani, A.
    Milian, F. M.
    Molinelli, S.
    Morone, M. C.
    Muraro, S.
    Orts, T.
    Patera, V.
    Sala, P.
    Schmitt, E.
    Vivaldo, G.
    Marchetto, F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (01) : 183 - 214
  • [23] Biological dose optimization incorporating intra-tumoural cellular radiosensitivity heterogeneity in ion-beam therapy treatment planning
    Inaniwa, Taku
    Kanematsu, Nobuyuki
    Koto, Masashi
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (11)
  • [24] Scanned carbon-ion beam therapy throughput over the first 7 years at National Institute of Radiological Sciences
    Mori, Shinichiro
    Takei, Yuka
    Shirai, Toshiyuki
    Hara, Yousuke
    Furukawa, Takuji
    Inaniwa, Taku
    Tanimoto, Katsuyuki
    Tajiri, Minoru
    Kuroiwa, Daigo
    Kimura, Taku
    Yamamoto, Naoyoshi
    Yamada, Shigeru
    Tsuji, Hiroshi
    Kamada, Tadashi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 52 : 18 - 26
  • [25] Commissioning of pencil beam and Monte Carlo dose engines for non-isocentric treatments in scanned proton beam therapy
    Carlino, A.
    Boehlen, T.
    Vatnitsky, S.
    Grevillot, L.
    Osorio, J.
    Dreindl, R.
    Palmans, H.
    Stock, M.
    Kragl, G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (17)
  • [26] Development and validation of MonteRay, a fast Monte Carlo dose engine for carbon ion beam radiotherapy
    Lysakovski, Peter
    Kopp, Benedikt
    Tessonnier, Thomas
    Mein, Stewart
    Ferrari, Alfredo
    Haberer, Thomas
    Debus, Juergen
    Mairani, Andrea
    MEDICAL PHYSICS, 2024, 51 (02) : 1433 - 1449
  • [27] Upgrade and benchmarking of a 4D treatment planning system for scanned ion beam therapy
    Richter, D.
    Schwarzkopf, A.
    Trautmann, J.
    Kraemer, M.
    Durante, M.
    Jaekel, O.
    Bert, C.
    MEDICAL PHYSICS, 2013, 40 (05)
  • [28] Residual motion mitigation in scanned carbon ion beam therapy of liver tumors using enlarged pencil beam overlap
    Richter, Daniel
    Graeff, Christian
    Jaekel, Oliver
    Combs, Stephanie E.
    Durante, Marco
    Bert, Christoph
    RADIOTHERAPY AND ONCOLOGY, 2014, 113 (02) : 290 - 295
  • [29] Commissioning of an Integrated Platform for Time-Resolved Treatment Delivery in Scanned Ion Beam Therapy by Means of Optical Motion Monitoring
    Fattori, G.
    Saito, N.
    Seregni, M.
    Kaderka, R.
    Pella, A.
    Constantinescu, A.
    Riboldi, M.
    Steidl, P.
    Cerveri, P.
    Bert, C.
    Durante, M.
    Baroni, G.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2014, 13 (06) : 517 - 528
  • [30] The GATE-RTion/IDEAL Independent Dose Calculation System for Light Ion Beam Therapy
    Grevillot, L.
    Boersma, D. J.
    Fuchs, H.
    Bolsa-Ferruz, M.
    Scheuchenpflug, L.
    Georg, D.
    Kronreif, G.
    Stock, M.
    FRONTIERS IN PHYSICS, 2021, 9