Fast optimization and dose calculation in scanned ion beam therapy

被引:7
作者
Hild, S. [1 ,2 ,3 ,4 ]
Graeff, C. [5 ]
Trautmann, J. [5 ]
Kraemer, M. [5 ]
Zink, K. [4 ,6 ]
Durante, M. [5 ,7 ]
Bert, C. [2 ,3 ,5 ]
机构
[1] GSI Helmholtzzentrum Schwerionenforsch GmbH, Dept Biophys, D-64291 Darmstadt, Germany
[2] Univ Clin Erlangen, Dept Radiat Oncol, D-91054 Erlangen, Germany
[3] Friedrich Alexander Univ Erlangen Nurnberg FAU, D-91054 Erlangen, Germany
[4] Univ Appl Sci, Inst Med Phys & Radiat Protect, D-35390 Giessen, Germany
[5] GSI Helmholtzzentrum Schwerionenforsch GmbH, Dept Biophys, D-64289 Darmstadt, Germany
[6] Univ Hosp Giessen Marburg, Dept Radiotherapy & Radiooncol, D-35043 Marburg, Germany
[7] Tech Univ Darmstadt, Fac Phys, D-64289 Darmstadt, Germany
关键词
particle therapy; prostate cancer; adaptive treatment planning; fast dose calculation; RADIOTHERAPY; SYSTEM; CT; DESIGN; TUMORS; MODEL;
D O I
10.1118/1.4881522
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Particle therapy (PT) has advantages over photon irradiation on static tumors. An increased biological effectiveness and active target conformal dose shaping are strong arguments for PT. However, the sensitivity to changes of internal geometry complicates the use of PT for moving organs. In case of interfractionally moving objects adaptive radiotherapy (ART) concepts known from intensity modulated radiotherapy (IMRT) can be adopted for PT treatments. One ART strategy is to optimize a new treatment plan based on daily image data directly before a radiation fraction is delivered [treatment replanning (TRP)]. Optimizing treatment plans for PT using a scanned beam is a time consuming problem especially for particles other than protons where the biological effective dose has to be calculated. For the purpose of TRP, fast optimization and fast dose calculation have been implemented into the GSI in-house treatment planning system (TPS) TRiP98. Methods: This work reports about the outcome of a code analysis that resulted in optimization of the calculation processes as well as implementation of routines supporting parallel execution of the code. To benchmark the new features, the calculation time for therapy treatment planning has been studied. Results: Compared to the original version of the TPS, calculation times for treatment planning (optimization and dose calculation) have been improved by a factor of 10 with code optimization. The parallelization of the TPS resulted in a speedup factor of 12 and 5.5 for the original version and the code optimized version, respectively. Hence the total speedup of the new implementation of the authors' TPS yielded speedup factors up to 55. Conclusions: The improved TPS is capable of completing treatment planning for ion beam therapy of a prostate irradiation considering organs at risk in this has been overseen in the review process. Also see below 6 min. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A 4D-optimization concept for scanned ion beam therapy
    Graeff, Christian
    Luechtenborg, Robert
    Eley, John Gordon
    Durante, Marco
    Bert, Christoph
    RADIOTHERAPY AND ONCOLOGY, 2013, 109 (03) : 419 - 424
  • [2] 4D optimization of scanned ion beam tracking therapy for moving tumors
    Eley, John Gordon
    Newhauser, Wayne David
    Luechtenborg, Robert
    Graeff, Christian
    Bert, Christoph
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (13) : 3431 - 3452
  • [3] Scanned ion beam therapy for prostate carcinoma
    Hild, Sebastian
    Graeff, Christian
    Rucinski, Antoni
    Zink, Klemens
    Habl, Gregor
    Durante, Marco
    Herfarth, Klaus
    Bert, Christoph
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (02) : 118 - 126
  • [4] Motion mitigation in scanned ion beam therapy through 4D-optimization
    Graeff, Christian
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (05): : 570 - 577
  • [5] A trichrome beam model for biological dose calculation in scanned carbon-ion radiotherapy treatment planning
    Inaniwa, T.
    Kanematsu, N.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (01) : 437 - 451
  • [6] Multigating, a 4D Optimized Beam Tracking in Scanned Ion Beam Therapy
    Graeff, Christian
    Constantinescu, Anna
    Luechtenborg, Robert
    Durante, Marco
    Bert, Christoph
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2014, 13 (06) : 497 - 504
  • [7] Feature-based plan adaptation for fast treatment planning in scanned ion beam therapy
    Chen, Wenjing
    Gemmel, Alexander
    Rietzel, Eike
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (04) : 1013 - 1025
  • [8] Fast spot order optimization to increase dose rates in scanned particle therapy FLASH treatments
    Wase, Viktor
    Widenfalk, Oscar
    Nilsson, Rasmus
    Falth, Claes
    Fredriksson, Albin
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (02)
  • [9] Robustness of target dose coverage to motion uncertainties for scanned carbon ion beam tracking therapy of moving tumors
    Eley, John Gordon
    Newhauser, Wayne David
    Richter, Daniel
    Luechtenborg, Robert
    Saito, Nami
    Bert, Christoph
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (04) : 1717 - 1740
  • [10] Calculation and experimental verification of the RBE-weighted dose for scanned ion beams in the presence of target motion
    Gemmel, A.
    Rietzel, E.
    Kraft, G.
    Durante, M.
    Bert, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (23) : 7337 - 7351