Evaluate the performance of four artificial intelligence-aided diagnostic systems in identifying and measuring four types of pulmonary nodules

被引:3
|
作者
Wu, Ming-yue [1 ]
Li, Yong [2 ]
Fu, Bin-jie [2 ]
Wang, Guo-shu [2 ]
Chu, Zhi-gang [2 ]
Deng, Dan [1 ]
机构
[1] Chongqing Med Univ, Sch Publ Hlth & Management, Chongqing, Peoples R China
[2] Chongqing Med Univ, Affiliated Hosp 1, Dept Radiol, Chongqing, Peoples R China
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2021年 / 22卷 / 01期
关键词
artificial intelligence; lung phantom; pulmonary nodules; GROUND-GLASS OPACITY; ITERATIVE RECONSTRUCTION; COMPUTED-TOMOGRAPHY; LUNG-CANCER; CT; VOLUMETRY; VARIABILITY;
D O I
10.1002/acm2.13142
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose This study aims to evaluate the performance of four artificial intelligence-aided diagnostic systems in identifying and measuring four types of pulmonary nodules. Methods Four types of nodules were implanted in a commercial lung phantom. The phantom was scanned with multislice spiral computed tomography, after which four systems (A, B, C, D) were used to identify the nodules and measure their volumes. Results The relative volume error (RVE) of system A was the lowest for all nodules, except for small ground glass nodules (SGGNs). System C had the smallest RVE for SGGNs, -0.13 (-0.56, 0.00). In the Bland-Altman test, only systems A and C passed the consistency test, P = 0.40. In terms of precision, the miss rate (MR) of system C was 0.00% for small solid nodules (SSNs), ground glass nodules (GGNs), and solid nodules (SNs) but 4.17% for SGGNs. The comparable system D MRs for SGGNs, SSNs, and GGNs were 71.30%, 25.93%, and 47.22%, respectively, the highest among all the systems. Receiver operating characteristic curve analysis indicated that system A had the best performance in recognizing SSNs and GGNs, with areas under the curve of 0.91 and 0.68. System C had the best performance for SGGNs (AUC = 0.91). Conclusion Among four types nodules, SGGNs are the most difficult to recognize, indicating the need to improve higher accuracy and precision of artificial systems. System A most accurately measured nodule volume. System C was most precise in recognizing all four types of nodules, especially SGGN.
引用
收藏
页码:318 / 326
页数:9
相关论文
共 2 条
  • [1] Artificial Intelligence-Aided Diagnosis Software to Identify Highly Suspicious Pulmonary Nodules
    Lv, Jun
    Li, Jianhui
    Liu, Yanzhen
    Zhang, Hong
    Luo, Xiangfeng
    Ren, Min
    Gao, Yufan
    Ma, Yanhe
    Liang, Shuo
    Yang, Yapeng
    Song, Zhenchun
    Gao, Guangming
    Gao, Guozheng
    Jiang, Yusheng
    Li, Ximing
    FRONTIERS IN ONCOLOGY, 2022, 11
  • [2] Performance of Artificial Intelligence-Aided Diagnosis System for Clinically Significant Prostate Cancer with MRI: A Diagnostic Comparison Study
    Jiang, Ke-Wen
    Song, Yang
    Hou, Ying
    Zhi, Rui
    Zhang, Jing
    Bao, Mei-Ling
    Li, Hai
    Yan, Xu
    Xi, Wei
    Zhang, Cheng-Xiu
    Yao, Ye-Feng
    Yang, Guang
    Zhang, Yu-Dong
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (05) : 1352 - 1364