Performance and selectivity of cationic nanoparticle pseudo-stationary phases in electrokinetic chromatography

被引:7
|
作者
McGettrick, Julie R. [1 ]
Williamson, Nathan H. [2 ]
Sutton, Adam T. [2 ]
Palmer, Christopher P. [1 ]
机构
[1] Univ Montana, Dept Chem & Biochem, 32 Campus Dr, Missoula, MT 59812 USA
[2] Univ South Australia, Future Ind Inst, Mawson Lakes, SA, Australia
基金
美国国家科学基金会;
关键词
Cationic; Electrokinetic chromatography; Nanoparticle; Pseudo-stationary phase; RAFT; PSEUDOSTATIONARY PHASE; CAPILLARY-ELECTROPHORESIS; NEUTRAL COMPOUNDS; MOLECULAR-WEIGHT; SEPARATION; POLYETHYLENEIMINE; POLYMERIZATION; COPOLYMERS; PROTEINS; POLYMERS;
D O I
10.1002/elps.201600380
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Electrokinetic chromatography (EKC) is a powerful analytical technique that uses an ionic pseudo-stationary phase (PSP) to separate neutral compounds. Although anionic surfactants are the most common choice for PSP, cationic latex nanoparticles are an attractive alternative. Reversible addition-fragmentation chain transfer (RAFT) polymerization was used to synthesize several types of diblock copolymers that self-assemble into latex nanoparticles, which were characterized by a variety of techniques including diffusion NMR. The performance of each nanoparticle as a PSP was studied by using a homologous series of ketones and linear solvation energy relationships (LSER) analysis. A cationic homopolymer coating was found to be necessary to prevent band broadening caused by analyte interactions with nanoparticles adsorbed to the capillary surface. No significant difference in methylene selectivity or LSER parameters was observed between nanoparticles with different cationic shells, but differences were observed between nanoparticles with different hydrophobic cores. Cationic latex nanoparticles behaved more like anionic latex nanoparticles than like cationic surfactants, suggesting that selectivity is primarily driven by the hydrophobic portion of a PSP. Cationic latex nanoparticles in combination with a homopolymer cationic capillary coating are an excellent choice for EKC analyses where an anodic electroosmotic flow is required.
引用
收藏
页码:730 / 737
页数:8
相关论文
共 50 条
  • [1] DENDRIMERS AS PSEUDO-STATIONARY PHASES IN ELECTROKINETIC CHROMATOGRAPHY
    MUIJSELAAR, PGHM
    CLAESSENS, HA
    CRAMERS, CA
    JANSEN, JFGA
    MEIJER, EW
    DEBRABANDERVANDENBERG, EMM
    VANDERWAL, S
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1995, 18 (02): : 121 - 123
  • [2] Sulfonated acrylamide copolymers as pseudo-stationary phases in electrokinetic chromatography
    Shi, W
    Watson, CJ
    Palmer, CP
    JOURNAL OF CHROMATOGRAPHY A, 2001, 905 (1-2) : 281 - 290
  • [3] Application of particles as pseudo-stationary phases in electrokinetic chromatography
    Gottlicher, B
    Bachmann, K
    JOURNAL OF CHROMATOGRAPHY A, 1997, 780 (1-2) : 63 - 73
  • [4] Hydrophobic deep eutectic solvents as pseudo-stationary phases in capillary electrokinetic chromatography: An explorative study
    Li, Ang
    Xue, Song
    Ren, Siru
    Xu, Yu
    Zhang, Qi
    ANALYTICA CHIMICA ACTA, 2022, 1213
  • [5] Developments in the use of soluble ionic polymers as pseudo-stationary phases for electrokinetic chromatography and stationary phases for electrochromatography
    Palmer, CP
    McCarney, JP
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1044 (1-2) : 159 - 176
  • [6] Nanoparticles as stationary and pseudo-stationary phases in chromatographic and electrochromatographic separations
    Duan, Ai-Hong
    Xie, Sheng-Ming
    Yuan, Li-Ming
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2011, 30 (03) : 484 - 491
  • [7] Chiral separation by capillary electrokinetic chromatography with hydrophobic deep eutectic solvents as pseudo-stationary phases
    Xu, Yu
    Li, Ang
    Xue, Song
    Ding, Sihui
    Zhang, Qi
    TALANTA, 2023, 260
  • [8] Polymeric surfactants as pseudo-stationary phases for separations in electrokinetic chromatography (EKC): A review
    Haynes, JL
    Warner, IM
    REVIEWS IN ANALYTICAL CHEMISTRY, 1999, 18 (06): : 317 - 382
  • [9] On-column sample preconcentration in electrokinetic chromatography by sweeping with polymeric pseudo-stationary phases
    Shi, W
    Palmer, CP
    JOURNAL OF SEPARATION SCIENCE, 2002, 25 (04) : 215 - 221
  • [10] Effect of pendant chain lengths and backbone functionalities on the chemical selectivity of sulfonated amphiphilic copolymers as pseudo-stationary phases in electrokinetic chromatography
    Shi, W
    Peterson, DS
    Palmer, CP
    JOURNAL OF CHROMATOGRAPHY A, 2001, 924 (1-2) : 123 - 135