Determination of thiamine in blood serum and urine by high-performance liquid chromatography with direct injection and post-column derivatization

被引:25
|
作者
Bohrer, D [1 ]
do Nascimento, PC
Ramirez, AG
Mendonça, JKA
de Carvalho, LM
Pomblum, SCG
机构
[1] Univ Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
[2] Univ Fed Santa Maria, Dept Anal Clin & Toxicol, BR-97105900 Santa Maria, RS, Brazil
关键词
SPE; polyethylene; serum; urine; vitamin B-1;
D O I
10.1016/j.microc.2004.03.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Thiamine (vitamin B1) was determined in human serum and urine by HPLC with fluorimetric detection of its oxidation product, thiochrome. The samples were injected directly into the chromatographic system without previous treatment or dilution. A column filled with an ultra-high molecular weight surface-modified polyethylene (PE) was able to separate matrix components from analyte and also to allow a good chromatographic resolution of thiamine. The interaction of thiamine, thiocrome and both matrices (serum and urine) with PE was studied off- and on-line to determine the optimal procedure for vitamin B1 determination. When carried off-line, matrix adsorption yield was 49 mg serum proteins/g polymer and components of 1000 mul urine/g polymer. In an on-line arrangement, the yield dropped to 10 mg/g and 150 mul/g, respectively. The matrix/analyte separation was carried out in an on-line procedure on a 50x4.6-mm, 25-mum PE column, using a water-sodium phosphate-methanol gradient elution. Part of the matrix was eluted within the first 2 min and thiamine after 3.8 min. The rest of the matrix retained on the column was eluted after thiamine at the last step of the gradient elution. Analysis time was 12 min. The within-day and day-to-day precision gave C.V. varying from 3.6% to 14.5% and recoveries from spiked samples were in the range of 84.8-98.8%. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 50 条
  • [31] LIQUID-CHROMATOGRAPHY WITH POST-COLUMN DERIVATIZATION
    FREI, RW
    BRINKMAN, UAT
    ACTA PHARMACEUTICA SUECICA, 1982, 19 (01): : 65 - 65
  • [32] Determination of kynurenine in serum by high-performance liquid chromatography with on-column fluorescence derivatization
    Luo, Xibo
    Tang, Aiguo
    Pi, Langan
    Xiao, Ledong
    Ao, Xiang
    Pu, Yanhong
    Wang, Rui
    CLINICA CHIMICA ACTA, 2008, 389 (1-2) : 186 - 188
  • [33] Determination of disodium cromoglycate in human urine by high-performance liquid chromatography with post-column photoirradiation-fluorescence detection
    Mawatari, K
    Mashiko, S
    Sate, Y
    Usui, Y
    Iinuma, F
    Watanabe, M
    ANALYST, 1997, 122 (07) : 715 - 717
  • [34] Fluorometric determination of pantothenic acid in human urine by isocratic reversed-phase ion-pair high-performance liquid chromatography with post-column derivatization
    Takahashi, Kei
    Fukuwatari, Tsutomu
    Shibata, Katsumi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (22): : 2168 - 2172
  • [35] DETERMINATION OF OXYTETRACYCLINE IN BLOOD-SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH DIRECT INJECTION
    UENO, R
    UNO, K
    AOKI, T
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 573 (02): : 333 - 335
  • [36] Selectable-power photoreactor for flow-injection analysis systems and high-performance liquid chromatography post-column photochemical derivatization
    Lores, M
    Garcia, CM
    Cela, R
    JOURNAL OF CHROMATOGRAPHY A, 1996, 724 (1-2) : 55 - 65
  • [37] POST-COLUMN DERIVATIZATION PROCEDURE FOR THE COLORIMETRIC ANALYSIS OF TISSUE CANNABINOIDS SEPARATED BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    BORYS, HK
    KARLER, R
    JOURNAL OF CHROMATOGRAPHY, 1981, 205 (02): : 303 - 323
  • [38] DETERMINATION OF TAMOXIFEN AND METABOLITES IN HUMAN-SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH POST-COLUMN FLUORESCENCE ACTIVATION
    BROWN, RR
    BAIN, R
    JORDAN, VC
    JOURNAL OF CHROMATOGRAPHY, 1983, 272 (02): : 351 - 358
  • [39] Development and validation of a high-performance liquid chromatography method with post-column derivatization for the detection of aflatoxins in cereals and grains
    Asghar, Muhammad Asif
    Iqbal, Javed
    Ahmed, Aftab
    Khan, Mobeen Ahmed
    Shamsuddin, Zuzzer Ali
    Jamil, Khalid
    TOXICOLOGY AND INDUSTRIAL HEALTH, 2016, 32 (06) : 1122 - 1134
  • [40] Fluorescence detection of cardenolides in reversed-phase high-performance liquid chromatography after post-column derivatization
    Belsner, K
    Buchele, B
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 682 (01): : 95 - 107