Prediction of pressure drop in a packed bed dehumidifier operating with liquid desiccant

被引:64
|
作者
Gandhidasan, P [1 ]
机构
[1] King Fahd Univ Petr & Minerals, Dept Mech Engn, Dhahran 31261, Saudi Arabia
关键词
dehumidifier; liquid desiccant; packed bed; pressure drop;
D O I
10.1016/S1359-4311(02)00031-5
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper a more rigorous model, which is valid for both structured and random packing columns, is used for predicting the irrigated pressure drop in a desiccant-air contact system. Calcium chloride solution is considered as the desiccant. Four different random packing materials and three different structured packing materials are considered in the present study. The effects of random packing shape and the type of structured packing on the hydraulic performance are studied. The model has been validated for a wide range of operating values available in the literature. It is found that the structured packing has the lower pressure drop and higher capacity compared with random packings. Among the random packing materials considered in the present study, Intalox saddles can provide the least irrigated pressure drop and among the structured packing materials the sheet-type Mellapak 250 Y has the lowest pressure drop. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1117 / 1127
页数:11
相关论文
共 50 条
  • [1] Design and development of wire-mesh packed bed liquid desiccant dehumidifier to reduce pressure-drop and carryover
    Sonowal, Juri
    Muthukumar, P.
    Anandalakshmi, R.
    APPLIED THERMAL ENGINEERING, 2025, 261
  • [2] Performance study on the dehumidifier of a packed bed liquid desiccant system
    Salarian, H.
    Ghorbani, B.
    Amidpour, Majid
    Salehi, G.
    SCIENTIA IRANICA, 2014, 21 (01) : 222 - 228
  • [3] Cosorption processes of triethylene glycol in a packed bed liquid desiccant dehumidifier
    Chau, CK
    Worek, WM
    PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2, 2003, : 1021 - 1036
  • [4] Cosorption Processes of Triethylene Glycol in a Packed-Bed Liquid Desiccant Dehumidifier
    Chau, C. K.
    Worek, W. M.
    HVAC&R RESEARCH, 2009, 15 (02): : 189 - 210
  • [5] Effectiveness of heat and mass transfer processes in a packed bed liquid desiccant dehumidifier/regenerator
    Martin, V
    Goswami, DY
    HVAC&R RESEARCH, 2000, 6 (01): : 21 - 39
  • [6] Experimental study of the heat and mass transfer in a packed bed liquid desiccant air dehumidifier
    Oberg, V
    Goswami, DY
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (04): : 289 - 297
  • [7] Quick performance prediction of liquid desiccant regeneration in a packed bed
    Gandhidasan, P
    SOLAR ENERGY, 2005, 79 (01) : 47 - 55
  • [8] Coupled heat and mass transfer characteristic in packed bed dehumidifier/regenerator using liquid desiccant
    Liu, X. H.
    Jiang, Y.
    ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (06) : 1357 - 1366
  • [9] Study of a waste heat driven modified packed desiccant bed dehumidifier
    Fathalah, K
    Aly, SE
    ENERGY CONVERSION AND MANAGEMENT, 1996, 37 (04) : 457 - 471
  • [10] Experimental study on performance of celdek packed liquid desiccant dehumidifier
    Rakesh Kumar
    A. K. Asati
    Heat and Mass Transfer, 2016, 52 : 1821 - 1832