Care Regimen and Lens Material Influence on Silicone Hydrogel Contact Lens Deposition

被引:76
作者
Zhao, Zhenjun [1 ,2 ,3 ]
Camt, Nicole A. [1 ,3 ]
Aliwarga, Yulina [1 ,3 ]
Wei, Xiaojia [1 ,3 ]
Naduvilath, Thomas [1 ,3 ]
Garrett, Qian [1 ,2 ,3 ]
Korth, John [4 ]
Willcox, Mark D. P. [1 ,2 ,3 ]
机构
[1] Univ New S Wales, Eye Res Inst, Sydney, NSW 2052, Australia
[2] Univ New S Wales, Sch Optometry & Vis Sci, Sydney, NSW 2052, Australia
[3] Vis Cooperat Res Ctr, Sydney, NSW, Australia
[4] Univ Wollongong, Dept Chem, Wollongong, NSW 2500, Australia
关键词
Silicone hydrogel contact lenses; lens care solutions; lipids; proteins; cholesterol; IN-VITRO; GROUP-II; PSEUDOMONAS-AERUGINOSA; LIPID DEPOSITION; EXTENDED WEAR; PROTEIN; ADSORPTION; SURFACE; KINETICS; SORPTION;
D O I
10.1097/OPX.0b013e318196a74b
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To quantitatively detect proteins and cholesterol extracted from worn silicone hydrogel contact lenses and determine the effect of various lens care solutions on deposit accumulation. Methods. Contact lenses, made from different polymers and worn on a daily wear schedule with different lens care solutions, were collected. Lipid and protein deposits were extracted by methanol:chloroform (1:1, v/v) and protein extraction solution (containing urea and surfactant), respectively. Lipid extracts were separated and cholesterol quantified using thin layer chromatography. Protein extracts were quantified using standard techniques. Results. Among all lenses tested, Balafilcon A lenses exhibited greatest extracted cholesterol (4.1 to 8.2 mu g/lens) and total protein (5.4 to 23.2 mu g/lens). AQuify was the most effective solution in reducing extracted deposits, especially extracted protein, from Balafilcon A lenses. AQuify and Opti-Free RepleniSH solutions were most effective in reducing extracted cholesterol from Senofilcon A and Galyfilcon A lenses, respectively. Use of Opti-Free Express solution resulted in more extracted protein from Lotrafilcon B lenses than use of other solutions. Generally, Lotrafilcon 13, Senofilcon A, and Galyfilcon A lenses accumulated relatively low amount of proteins. Lotrafilcon B lenses accumulated the least amount of cholesterol deposit among all lenses tested regardless of solution used. Conclusions. Lens polymer (possibly associated with surface characteristics) is a prominent factor affecting lipid and protein accumulation. Within a lens polymer type, lens care solutions exhibit varying effectiveness in reducing protein and lipid accumulation.
引用
收藏
页码:251 / 259
页数:9
相关论文
共 46 条
[1]  
Bontempo Andrew R., 2001, CLAO Journal, V27, P75
[2]   Protein-lipid interaction on the surface of a hydrophilic contact lens in vitro [J].
Bontempo, AR ;
Rapp, J .
CURRENT EYE RESEARCH, 1997, 16 (08) :776-781
[3]   AN ANALYSIS OF TRANSFORMATIONS [J].
BOX, GEP ;
COX, DR .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 1964, 26 (02) :211-252
[4]   PROTEIN ADSORPTION STUDIES ON STANDARD POLYMERIC MATERIALS [J].
BRASH, JL ;
TENHOVE, P .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 1993, 4 (06) :591-599
[5]   CONTACT-LENS SURFACE DEPOSITS INCREASE THE ADHESION OF PSEUDOMONAS-AERUGINOSA [J].
BUTRUS, SI ;
KLOTZ, SA .
CURRENT EYE RESEARCH, 1990, 9 (08) :717-724
[6]   EFFECT OF MACROMOLECULES ON AQUEOUS SOLUBILITY OF CHOLESTEROL AND HORMONE DRUGS [J].
CADWALLADER, DE ;
MADAN, DK .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1981, 70 (04) :442-446
[7]   The adsorption of major tear film lipids in vitro to various silicone hydrogels over time [J].
Carney, Fiona P. ;
Nash, Walter L. ;
Sentell, Karen B. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (01) :120-124
[8]  
Caron Patrick, 2007, Optometry, V78, P23, DOI 10.1016/j.optm.2006.06.017
[9]   Human lens lipids differ markedly from those of commonly used experimental animals [J].
Deeley, Jane M. ;
Mitchell, Todd W. ;
Wei, Xiaojia ;
Korth, John ;
Nealon, Jessica R. ;
Blanksby, Stephen J. ;
Truscott, Roger J. W. .
BIOCHIMICA ET BIOPHYSICA ACTA-MOLECULAR AND CELL BIOLOGY OF LIPIDS, 2008, 1781 (6-7) :288-298
[10]  
Dumbleton Kathy, 2003, Eye Contact Lens, V29, pS186