Continuous Glucose Monitoring: A Brief Review for Primary Care Practitioners

被引:72
作者
Ajjan, Ramzi [1 ]
Slattery, David [2 ]
Wright, Eugene [3 ]
机构
[1] Univ Leeds, Leeds Inst Cardiovasc & Metab Med, LIGHT Labs, Leeds, W Yorkshire, England
[2] York Teaching Hosp NHS Fdn Trust, Endocrinol & Metab Med, York, N Yorkshire, England
[3] Duke Southern Reg AHEC, Dept Med & Community & Family Med, Fayetteville, NC USA
关键词
Continuous glucose monitoring; Diabetes; Flash glucose monitoring; Glycemic variability; HbA1c; Hypoglycemia; AMERICAN-DIABETES-ASSOCIATION; QUALITY-OF-LIFE; DAILY INSULIN INJECTIONS; MEASURED BLOOD-GLUCOSE; ALL-CAUSE MORTALITY; GLYCEMIC CONTROL; SEVERE HYPOGLYCEMIA; REAL-TIME; CLINICAL ENDOCRINOLOGISTS; COGNITIVE PERFORMANCE;
D O I
10.1007/s12325-019-0870-x
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Glycated hemoglobin A1c (HbA1c) is routinely used as a marker of average glycemic control, but it fails to provide data on hypoglycemia and glycemic variability, both of which are associated with adverse clinical outcomes. Self-monitoring of blood glucose (SMBG), particularly in insulin-treated patients, is a cornerstone in the management of patients with diabetes. SMBG helps with treatment decisions that aim to reduce high glucose levels while avoiding hypoglycemia and limiting glucose variability. However, repeated SMBG can be inconvenient to patients and difficult to maintain in the long term. By contrast, continuous glucose monitoring (CGM) provides a convenient, comprehensive assessment of blood glucose levels, allowing the identification of high and low glucose levels, in addition to evaluating glycemic variability. CGM using newer detection and visualization systems can overcome many of the limitations of an HbA1c-based approach while addressing the inconvenience and fragmented glucose data associated with SMBG. When used together with HbA1c monitoring, CGM provides complementary information on glucose levels, thus facilitating the optimization of diabetes therapy while reducing the fear and risk of hypoglycemia. Here we review the capabilities and benefits of CGM, including cost-effectiveness data, and discuss the potential limitations of this glucose-monitoring strategy for the management of patients with diabetes.
引用
收藏
页码:579 / 596
页数:18
相关论文
共 113 条
[1]   Calibration of Minimally Invasive Continuous Glucose Monitoring Sensors: State-of-The-Art and Current Perspectives [J].
Acciaroli, Giada ;
Vettoretti, Martina ;
Facchinetti, Andrea ;
Sparacino, Giovanni .
BIOSENSORS-BASEL, 2018, 8 (01)
[2]   Standardizing Clinically Meaningful Outcome Measures Beyond HbA1c for Type 1 Diabetes: A Consensus Report of the American Association of Clinical Endocrinologists, the American Association of Diabetes Educators, the American Diabetes Association, the Endocrine Society, JDRF International, The Leona M. and Harry B. Helmsley Charitable Trust, the Pediatric Endocrine Society, and the T1D Exchange [J].
Agiostratidou, Gina ;
Anhalt, Henry ;
Ball, Dana ;
Blonde, Lawrence ;
Gourgari, Evgenia ;
Harriman, Karen N. ;
Kowalski, Aaron J. ;
Madden, Paul ;
McAuliffe-Fogarty, Alicia H. ;
McElwee-Malloy, Molly ;
Peters, Anne ;
Raman, Sripriya ;
Reifschneider, Kent ;
Rubin, Karen ;
Weinzimer, Stuart A. .
DIABETES CARE, 2017, 40 (12) :1622-1630
[3]  
Ahn David, 2016, J Diabetes Sci Technol, V10, P793, DOI 10.1177/1932296816632241
[4]   How Can We Realize the Clinical Benefits of Continuous Glucose Monitoring? [J].
Ajjan, Ramzi A. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2017, 19 :S27-S36
[5]   REPLACE-BG: A Randomized Trial Comparing Continuous Glucose Monitoring With and Without Routine Blood Glucose Monitoring in Adults With Well-Controlled Type 1 Diabetes [J].
Aleppo, Grazia ;
Ruedy, Katrina J. ;
Riddlesworth, Tonya D. ;
Kruger, Davida F. ;
Peters, Anne L. ;
Hirsch, Irl ;
Bergenstal, Richard M. ;
Toschi, Elena ;
Ahmann, Andrew J. ;
Shah, Viral N. ;
Rickels, Michael R. ;
Bode, Bruce W. ;
Philis-Tsimikas, Athena ;
Pop-Busui, Rodica ;
Rodriguez, Henry ;
Eyth, Emily ;
Bhargava, Anuj ;
Kollman, Craig ;
Beck, Roy W. .
DIABETES CARE, 2017, 40 (04) :538-545
[6]   Hypoglycaemia in Type 2 diabetes [J].
Amiel, S. A. ;
Dixon, T. ;
Mann, R. ;
Jameson, K. .
DIABETIC MEDICINE, 2008, 25 (03) :245-254
[7]   A Multicenter Real-Life Study on the Effect of Flash Glucose Monitoring on Glycemic Control in Patients with Type 1 and Type 2 Diabetes [J].
Anjana, Ranjit Mohan ;
Kesavadev, Jothydev ;
Neeta, Deshpande ;
Tiwaskar, Mangesh ;
Pradeepa, Rajendra ;
Jebarani, Saravanan ;
Thangamani, Suresh ;
Sastry, Nadiminty Ganapathi ;
Kumar, Srivastava Brijendra ;
Ramu, Muthu ;
Gupta, Pokal Prasanna Kumar ;
Vignesh, Jayaprakash ;
Chandru, Sundramoorthy ;
Kayalvizhi, Sengottuvel ;
Jagdish, Padoor Sethuraman ;
Uthra, Subash Chandra Bose ;
Lovelena, Munawar ;
Jyoti, Sah ;
Priya, Sengodan Suguna ;
Kannan, Alagarsamy ;
Mohan, Viswanathan ;
Unnikrishnan, Ranjit .
DIABETES TECHNOLOGY & THERAPEUTICS, 2017, 19 (09) :533-540
[8]  
[Anonymous], 2018, DIABETES CARE, V41, pS1, DOI [10.2337/dc18-Sint01, 10.2337/dc18-SINT01]
[9]  
[Anonymous], 2018, AM J TRANSPLANT S1, V18, P10, DOI DOI 10.1109/JSEN.2018.2870228
[10]  
[Anonymous], J DIABETES INVESTIG