Performance characteristics of single photon pulse ranging system using Monte Carlo simulation

被引:5
作者
He, Weiji [1 ]
Chen, Yunfei [1 ]
Sima, Boyu [1 ]
Chen, Qian [1 ]
Gu, Guohua [1 ]
机构
[1] Nanjing Univ Sci & Technol, Jiangsu Key Lab Spectral Imaging & Intelligence S, Nanjing 210094, Jiangsu, Peoples R China
来源
OPTIK | 2013年 / 124卷 / 24期
关键词
Ladar; Ranging performance; Monte Carlo simulation;
D O I
10.1016/j.ijleo.2013.05.120
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Single photon pulse ranging system with extremely high sensitivity has been widely used in distance measurement and 3D imaging. To analyze the factors that affect the measurement precision and accuracy will help to improve system performance. According to system structure and principle, we mainly discussed the following factors: laser intensity, pulse width, detection efficiency and time jitter. A simulation model based on Monte Carlo stochastic method was constructed in this paper, and we get the specific influence of factors on measurement precision and accuracy by simulation. Finally, we set up laboratory experiment system and took effective experiments on ranging precision and accuracy. Crown Copyright (C) 2013 Published by Elsevier GmbH. All rights reserved.
引用
收藏
页码:6559 / 6564
页数:6
相关论文
共 10 条
[1]  
Albota M. A., 2002, Lincoln Laboratory Journal, V13, P351
[2]   Three-dimensional imaging laser radar with a photon-counting avalanche photodiode array and microchip laser [J].
Albota, MA ;
Heinrichs, RM ;
Kocher, DG ;
Fouche, DG ;
Player, BE ;
O'Brien, ME ;
Aull, BF ;
Zayhowski, JJ ;
Mooney, J ;
Willard, BC ;
Carlson, RR .
APPLIED OPTICS, 2002, 41 (36) :7671-7678
[3]   Detection and false-alarm probabilities for laser radars that use Geiger-mode detectors [J].
Fouche, DG .
APPLIED OPTICS, 2003, 42 (27) :5388-5398
[4]  
Gatt P, 2009, APPL OPTICS, V48, P3261, DOI [10.1364/AO.48.003261, 10.1364/AO.48.003262]
[5]   Smart three-dimensional imaging ladar using two Geiger-mode avalanche photodiodes [J].
Kong, Hong Jin ;
Kim, Tae Hoon ;
Jo, Sung Eun ;
Oh, Min Seok .
OPTICS EXPRESS, 2011, 19 (20) :19323-19329
[6]   Laser depth measurement based on time-correlated single-photon counting [J].
Massa, JS ;
Wallace, AM ;
Buller, GS ;
Fancey, SJ ;
Walker, AC .
OPTICS LETTERS, 1997, 22 (08) :543-545
[7]   Long-range time-of-flight scanning sensor based on high-speed time-correlated single-photon counting [J].
McCarthy, Aongus ;
Collins, Robert J. ;
Krichel, Nils J. ;
Fernandez, Veronica ;
Wallace, Andrew M. ;
Buller, Gerald S. .
APPLIED OPTICS, 2009, 48 (32) :6241-6251
[8]  
O'Brien M. E., 2005, Lincoln Laboratory Journal, V15, P37
[9]  
TUDISCO S, 2007, P SPIE, V6619
[10]   Range accuracy limitation of pulse ranging systems based on Geiger mode single-photon detectors [J].
Wang, Fei ;
Zhao, Yuan ;
Zhang, Yu ;
Sun, Xiudong .
APPLIED OPTICS, 2010, 49 (29) :5561-5566