Phase-Sensitive Inversion Recovery for Myocardial T1 Mapping with Motion Correction and Parametric Fitting

被引:83
作者
Xue, Hui [1 ]
Greiser, Andreas [2 ]
Zuehlsdorff, Sven [3 ]
Jolly, Marie-Pierre [1 ]
Guehring, Jens [2 ]
Arai, Andrew E. [4 ]
Kellman, Peter [4 ]
机构
[1] Siemens Corp, Corp Res, Princeton, NJ 08540 USA
[2] Siemens AG, Healthcare Sect, Imaging & Therapy Div, Erlangen, Germany
[3] Siemens Healthcare USA Inc, CMR R&D, Chicago, IL USA
[4] NHLBI, Cardiac Energet Lab, NIH, Bethesda, MD 20892 USA
关键词
T-1; mapping; phase-sensitive inversion recovery; motion correction; MOLLI; cardiac MRI; RESOLUTION; INFARCTION; MRI;
D O I
10.1002/mrm.24385
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The assessment of myocardial fibrosis and extracellular volume requires accurate estimation of myocardial T(1)s. While image acquisition using the modified Look-Locker inversion recovery technique is clinically feasible for myocardial T-1 mapping, respiratory motion can limit its applicability. Moreover, the conventional T-1 fitting approach using the magnitude inversion recovery images can lead to less stable T-1 estimates and increased computational cost. In this article, we propose a novel T-1 mapping scheme that is based on phase-sensitive image reconstruction and the restoration of polarity of the MR signal after inversion. The motion correction is achieved by registering the reconstructed images after background phase removal. The restored signal polarity of the inversion recovery signal helps the T-1 fitting resulting in improved quality of the T-1 map and reducing the computational cost. Quantitative validation on a data cohort of 45 patients proves the robustness of the proposed method against varying image contrast. Compared to the magnitude T-1 fitting, the proposed phase-sensitive method leads to less fluctuation in T-1 estimates. (C) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1408 / 1420
页数:13
相关论文
共 18 条
  • [1] Chefd'hotel C, 2002, 2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, P753
  • [2] Fast high-resolution T1 mapping of the human brain
    Deichmann, R
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (01) : 20 - 27
  • [3] MEASURES OF THE AMOUNT OF ECOLOGIC ASSOCIATION BETWEEN SPECIES
    DICE, LR
    [J]. ECOLOGY, 1945, 26 (03) : 297 - 302
  • [4] Ferreira VM, 2011, J CARDIOVASC MAGN S1, V13, pP16
  • [5] Measurement of the gadopentetate dimeglumine partition coefficient in human myocardium in vivo: Normal distribution and elevation in acute and chronic infarction
    Flacke, SJ
    Fischer, SE
    Lorenz, CH
    [J]. RADIOLOGY, 2001, 218 (03) : 703 - 710
  • [6] Musculoskeletal MRI at 3.0T: Relaxation times and image contrast
    Gold, GE
    Han, E
    Stainsby, J
    Wright, G
    Brittain, J
    Beaulieu, C
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (02) : 343 - 351
  • [7] Guetter C, 2011, I S BIOMED IMAGING, P590, DOI 10.1109/ISBI.2011.5872476
  • [8] Phase-sensitive inversion recovery for detecting myocardial infarction using gadolinium-delayed hyperenhancement
    Kellman, P
    Arai, AE
    McVeigh, ER
    Aletras, AH
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (02) : 372 - 383
  • [9] AN ALGORITHM FOR LEAST-SQUARES ESTIMATION OF NONLINEAR PARAMETERS
    MARQUARDT, DW
    [J]. JOURNAL OF THE SOCIETY FOR INDUSTRIAL AND APPLIED MATHEMATICS, 1963, 11 (02): : 431 - 441
  • [10] Human myocardium: Single-breath-hold MR T1 mapping with high spatial resolution - Reproducibility study
    Messroghli, DR
    Plein, S
    Higgins, DM
    Walters, K
    Jones, TR
    Ridgway, JP
    Sivananthan, MU
    [J]. RADIOLOGY, 2006, 238 (03) : 1004 - 1012