Comparative study of the prevention of seroma formation in immediate breast reconstruction with latissimus dorsi myocutaneous flaps

被引:1
作者
Hong, Seok Won [1 ]
Lee, Da Woon [1 ]
Choi, Hwan Jun [1 ]
Park, Eun Soo [2 ]
Kim, Jun Hyuk [1 ]
机构
[1] Soonchunhyang Univ, Coll Med, Dept Plast & Reconstruct Surg, Cheonan Hosp, 31 Suncheonhyang,6 Gil, Cheonan 31151, South Korea
[2] Soonchunhyang Univ, Dept Plast & Reconstruct Surg, Bucheon Hosp, Coll Med, Bucheon, South Korea
来源
ARCHIVES OF AESTHETIC PLASTIC SURGERY | 2020年 / 26卷 / 03期
关键词
Seroma; Myocutaneous flap; Breast; Harmonic scalpel; RANDOMIZED CLINICAL-TRIAL; FIBRIN SEALANT; QUILTING SUTURES; HARMONIC SCALPEL; DONOR-SITE; SURGERY; EFFICACY;
D O I
10.14730/aaps.2020.02096
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Latissimus dorsi (LD) flaps are often used in breast reconstruction procedures, but seroma formation is a frequent complication. To decrease the incidence of seroma formation, fibrin sealants and/or quilting sutures have been proposed, with controversial results. The primary objective of this study was to assess the effectiveness of the Harmonic scalpel in association with Tisseel and three-point deep dermal sutures in reducing the incidence of this complication. Methods A retrospective study was conducted of 108 patients undergoing immediate unilateral breast reconstruction with LD flaps over a 3-year period (2016-2018) by a single surgeon. In the experimental group, 37 patients underwent the procedure with a Harmonic scalpel and three-point deep dermal sutures (a modified version of quilting sutures), and the other 71 received conventional electrocautery. Fibrin sealant was applied to the donor site of all patents to reduce seroma formation. Results Statistically significant differences in the incidence of seroma were found between the two groups. There was a lower incidence of seroma formation in the group of patients treated with a Harmonic scalpel and three-point deep dermal sutures than in the other group. The total drainage amount and drain removal date between the two groups were not significantly different. Conclusions Within the limitations of this study, we suggest that Harmonic scalpel use can be a good choice among the many ways to reduce seroma formation following LD flap procedures, and that this technique will be very helpful for patients.
引用
收藏
页码:92 / 98
页数:7
相关论文
共 25 条
  • [1] [Anonymous], 2012, PAK J SURG
  • [2] Comparing the Harmonic Scalpel with Electrocautery in Reducing Postoperative Flap Necrosis and Seroma Formation after Modified Radical Mastectomy in Carcinoma Breast Patients: A Double-Blind Prospective Randomized Control Trail
    Archana, Arumugom
    Sureshkumar, Sathasivam
    Vijayakumar, Chellappa
    Palanivel, Chinnakali
    [J]. CUREUS, 2018, 10 (04):
  • [3] Latissimus Dorsi Donor-Site Morbidity The Combination of Quilting and Fibrin Sealant Reduce Length of Drain Placement and Seroma Rate
    Bailey, Steven H.
    Oni, Georgette
    Guevara, Rafael
    Wong, Corrine
    Saint-Cyr, Michel
    [J]. ANNALS OF PLASTIC SURGERY, 2012, 68 (06) : 555 - 558
  • [4] Harmonic Scalpel Versus Coblation Tonsillectomy A Comparative Study
    Basu, Soumik
    Sengupta, Anindita
    Dubey, Arya Brata
    Sengupta, Arunabha
    [J]. INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2019, 71 (04) : 498 - 503
  • [5] Efficacy of Fibrin Glue on Seroma Formation after Breast Surgery
    Bonjar, Mahmood Reza Miri
    Maghsoudi, Hemmat
    Samnia, Roya
    Saleh, Parviz
    Parsafar, Farhang
    [J]. INTERNATIONAL JOURNAL OF BREAST CANCER, 2012, 2012
  • [6] A Prospective Randomized Trial of the Efficacy of Marginal Quilting Sutures and Fibrin Sealant in Reducing the Incidence of Seromas in the Extended Latissimus Dorsi Donor Site
    Dancey, Anne Louise
    Cheema, Mubashir
    Thomas, Sunil S.
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2010, 125 (05) : 1309 - 1317
  • [7] THE LATISSIMUS-DORSI FLAP IN HEAD AND NECK RECONSTRUCTIVE SURGERY - A REVIEW OF 121 PROCEDURES
    DAVIS, JP
    NIELD, DV
    GARTH, RJN
    BREACH, NM
    [J]. CLINICAL OTOLARYNGOLOGY, 1992, 17 (06): : 487 - 490
  • [8] Autologous latissimus breast reconstruction: A 3-year clinical experience with 100 patients
    Delay, E
    Gounot, N
    Bouillot, A
    Zlatoff, P
    Rivoire, M
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1998, 102 (05) : 1461 - 1478
  • [9] Mastectomy using ultrasonic dissection: effect on seroma formation
    Galatius, H
    Okholm, M
    Hoffmann, J
    [J]. BREAST, 2003, 12 (05) : 338 - 341
  • [10] New risk factors for donor site seroma formation after latissimus dorsi flap breast reconstruction: 10-year period outcome analysis
    Gruber, Sabine
    Whitworth, Alexandra B.
    Kemmler, Georg
    Papp, Christoph
    [J]. JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2011, 64 (01) : 69 - 74