Partially Functional Electrode Modifications for Rapid Detection of Dopamine in Urine

被引:16
作者
Shukla, Rajendra P. [1 ,2 ]
Aroosh, Matan [1 ,2 ]
Matzafi, Alon [1 ,2 ]
Ben-Yoav, Hadar [1 ,2 ]
机构
[1] Ben Gurion Univ Negev, Nanobioelect Lab NBEL, Dept Biomed Engn, IL-8410501 Beer Sheva, Israel
[2] Ben Gurion Univ Negev, Ilse Katz Inst Nanoscale Sci & Technol, IL-8410501 Beer Sheva, Israel
关键词
chemometrics; electrode coatings; miniaturized biosensors; neurotransmitters; ELECTROCHEMICAL SENSORS; CARBON NANOTUBES; ASCORBIC-ACID; BIOELECTRONIC TONGUE; OXIDE NANOCOMPOSITE; CATALYTIC-ACTIVITY; SENSING PLATFORM; HIGH-PERFORMANCE; NEUROTRANSMITTERS; PHEOCHROMOCYTOMAS;
D O I
10.1002/adfm.202004146
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Designing functional materials as electrode coatings to transduce high-quality information about redox molecules in biofluids is crucial for developing the next-generation medical devices. Rapidly analyzing the neurotransmitter dopamine (DA) urinary levels can enable point-of-care testing for neuroendocrine tumors. A novel sensing electrodes array modified with biopolymer chitosan and electrocatalytic carbon nanotube films that can generate cross-reactive electrochemical signals from complex biofluids, such as undiluted urine, is presented. By generating cross-reactive signals, the feasibility of quantifying DA levels from unprocessed urine samples is demonstrated. The films' electrochemical activity is characterized and modeled the additive effect of the main redox interferants in urine (norepinephrine and uric acid) on the generated electrochemical signals that overlap and mask the electrochemical signature of DA. Finally, the feasibility of successfully quantifying urinary DA levels is demonstrated by investigating two calibration approaches: 1) using a synthetic solution (1.15 mu m root mean squared error (RMSE) and 4.2 mu m limit-of-detection (LoD) values), and 2) directly using the urine samples (2.5 mu m RMSE and 9.3 mu m LoD values). The outcome of this work will enhance the understanding of the overlapping and masking electrochemical signatures and their interactions with functional materials, providing better analytical tools to differentiate redox molecules in highly complex biofluids.
引用
收藏
页数:10
相关论文
共 86 条
[11]   Two-Photon Polymerization for Fabricating Structures Containing the Biopolymer Chitosan [J].
Correa, D. S. ;
Tayalia, P. ;
Cosendey, G. ;
dos Santos, D. S., Jr. ;
Aroca, R. F. ;
Mazur, E. ;
Mendonca, C. R. .
JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2009, 9 (10) :5845-5849
[12]   Water based homogenous carbon ink modified electrode as an efficient sensor system for simultaneous detection of ascorbic acid, dopamine and uric acid [J].
Dinesh, Bose ;
Saraswathi, Ramiah ;
Kumar, Annamalai Senthil .
ELECTROCHIMICA ACTA, 2017, 233 :92-104
[13]  
Diniz MER, 2015, J BRAZIL CHEM SOC, V26, P1684
[14]   FAST FOURIER-TRANSFORMS - A TUTORIAL REVIEW AND A STATE-OF-THE-ART [J].
DUHAMEL, P ;
VETTERLI, M .
SIGNAL PROCESSING, 1990, 19 (04) :259-299
[15]   Nanomaterials-Based Electrochemical Sensors for In Vitro and In Vivo Analyses of Neurotransmitters [J].
Durairaj, Sharmila ;
Sidhureddy, Boopathi ;
Cirone, Joseph ;
Chen, Aicheng .
APPLIED SCIENCES-BASEL, 2018, 8 (09)
[16]   Progress in Analytical Techniques for Determination of Urine Components [J].
Galezowska, Grazyna ;
Cieszynska-Semenowicz, Monika ;
Okragla, Emilia ;
Szychowska, Katarzyna ;
Wolska, Lidia .
SEPARATION AND PURIFICATION REVIEWS, 2017, 46 (04) :305-318
[17]   Independent Components Analysis of the Overlapping Voltammetric Signals [J].
Gorski, Lukasz ;
Kubiak, Wladyslaw W. ;
Jakubowska, Malgorzata .
ELECTROANALYSIS, 2016, 28 (07) :1470-1477
[18]   Automatic baseline correction in voltammetry [J].
Gorski, Lukasz ;
Ciepiela, Filip ;
Jakubowska, Malgorzata .
ELECTROCHIMICA ACTA, 2014, 136 :195-203
[19]   Nanogold based electrochemical sensor for determination of norepinephrine in biological fluids [J].
Goyal, Rajendra N. ;
Aziz, Md Abdul ;
Oyama, Munetaka ;
Chatterjee, Sanghamitra ;
Rana, Anoop Raj Singh .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 153 (01) :232-238
[20]   Determination of catecholamines in plasma and urine [J].
Grouzmann, Eric ;
Lamine, Faiza .
BEST PRACTICE & RESEARCH CLINICAL ENDOCRINOLOGY & METABOLISM, 2013, 27 (05) :713-723