Accuracy of screening mammography using single versus independent double interpretation

被引:47
作者
Taplin, SH
Rutter, CM
Seger, D
White, D
Brenner, RJ
机构
[1] Grp Hlth Cooperat Puget Sound, Ctr Hlth Studies, Seattle, WA 98124 USA
[2] Univ Washington, Dept Family Med, Seattle, WA 98195 USA
[3] Univ Washington, Dept Med, Seattle, WA 98195 USA
[4] Grp Hlth Cooperat Puget Sound, Dept Radiol, Tacoma, WA 98405 USA
[5] St Johns Hosp, Joyce Einsenberg Keefer Breast Ctr, Santa Monica, CA 90404 USA
关键词
D O I
10.2214/ajr.174.5.1741257
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. We conducted an analysis among 31 community radiologists to identify the average change in screening mammography interpretive accuracy afforded by independent double interpretation. MATERIALS AND METHODS. We assessed interpretive accuracy using a stratified random sample of test mammograms that included 30 women with cancer and 83 without. Radiologists were unaware of clinical information and of each other's assessments. We describe accuracy for individual radiologists and for double interpretation, including average sensitivity, specificity, diagnostic likelihood ratios positive and negative, and area under the receiver operating characteristic (ROC) curve. We also assessed weighted and nonweighted kappa statistics among all 465 pairs of radiologists and 31,465 pairs of unique pairs. The assessment for double interpretations used the "highest" (i.e., most abnormal) assessment of the two radiologists. We calculated the difference between each radiologist's individual accuracy and the average accuracy across that radiologist's 30 double interpretations. RESULTS. We found the following average accuracy statistics for individual radiologists: sensitivity, 79%; specificity, 81%; diagnostic likelihood ratio positive, 5.53; diagnostic likelihood ratio negative, 0.26; and area under the ROC curve, 0.85. The mean kappa statistic among radiologists for cancer cases increased with double interpretation from 0.59 to 0.70, and for noncancer cases from 0.30 to 0.34. Double interpretation resulted in an average increase in sensitivity of 7%, an average decrease in specificity of 11%, a decrease in diagnostic likelihood ratio positive of 2.35, a decrease in diagnostic likelihood ratio negative of 0.06, and an increase in area under the ROC curve of 0.02. CONCLUSION. Independent double interpretation does not increase accuracy as measured by the area under the ROC curve.
引用
收藏
页码:1257 / 1262
页数:6
相关论文
共 31 条
[1]   THE EFFICACY OF DOUBLE READING MAMMOGRAMS IN BREAST SCREENING [J].
ANDERSON, EDC ;
MUIR, BB ;
WALSH, JS ;
KIRKPATRICK, AE .
CLINICAL RADIOLOGY, 1994, 49 (04) :248-251
[2]   DOUBLE READING OF MAMMOGRAPHY SCREENING FILMS - ONE RADIOLOGIST OR 2 [J].
ANTTINEN, I ;
PAMILO, M ;
SOIVA, M ;
ROIHA, M .
CLINICAL RADIOLOGY, 1993, 48 (06) :414-421
[3]  
BASSETT LW, 1995, RADIOL CLIN N AM, V33, P1027
[4]   Effect of human variability on independent double: Reading in screening mammography [J].
Beam, CA ;
Sullivan, DC ;
Layde, PM .
ACADEMIC RADIOLOGY, 1996, 3 (11) :891-897
[5]   Variability in the interpretation of screening mammograms by US radiologists - Findings from a national sample [J].
Beam, CA ;
Layde, PM ;
Sullivan, DC .
ARCHIVES OF INTERNAL MEDICINE, 1996, 156 (02) :209-213
[6]   A comparison of cancer detection rates achieved by breast cancer screening programmes by number of readers, for one and two view mammography: results from the UK National Health Service breast screening programme [J].
Blanks, RG ;
Wallis, MG ;
Moss, SM .
JOURNAL OF MEDICAL SCREENING, 1998, 5 (04) :195-201
[7]  
BOYD NF, 1982, J NATL CANCER I, V68, P357
[8]   RULING OUT OR RULING IN DISEASE WITH THE MOST SENSITIVE OR SPECIFIC DIAGNOSTIC-TEST - SHORT-CUT OR WRONG TURN [J].
BOYKO, EJ .
MEDICAL DECISION MAKING, 1994, 14 (02) :175-179
[9]  
Brown J, 1996, BRIT MED J, V312, P809
[10]  
CAMPBELL KH, 1995, PREVENTIVE SERVICE U