Spinal Orthoses: The Crucial Role of Comfort on Compliance of Wearing - Monocentric Prospective Pilot Study of Randomized Cross-Over Design

被引:0
|
作者
Herget, G. W. [1 ,2 ]
Patermann, S. [3 ]
Strohm, P. C. [4 ]
Zwingmann, J. [1 ]
Eichelberger, P. [5 ]
Suedkamp, N. P. [1 ]
Hirschmueller, A. [1 ]
机构
[1] Univ Med Ctr Freiburg, Dept Orthoped & Traumatol, Freiburg, Germany
[2] Univ Med Ctr Freiburg, Comprehens Canc Ctr Freiburg, Freiburg, Germany
[3] Loretto Hosp Freiburg, Dept Orthoped, Freiburg, Germany
[4] Sozialstiftung Bamberg, Dept Orthoped & Traumatol, Bamberg, Germany
[5] Univ Appl Sci, Hlth Div, Bern, Switzerland
关键词
thoracolumbar spine; orthoses; SF-12-Quality of Life QoL; comfort; compliance; HEALTH SURVEY; BRACE; SF-12;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PURPOSE OF THE STUDY Various spine disorders are regularly treated by orthoses, and success of treatment depends on wearing these devices. In this study we examined the compliance, wear comfort, subjective stabilization and side effects associated with spinal orthoses using an individualized questionnaire and the Compact Short Form-12 Health Survey (SF-12). MATERIAL AND METHODS In this prospective pilot study of randomized cross-over design, twelve healthy volunteers with a mean age of 31.2 years wore three different types of orthoses, each for one week: A hyperextension brace (HB), a custom-made semirigid orthosis (SO) and a custom-made rigid orthosis (RO). The daily duration of wearing the orthosis was defined as primary endpoint; contentment was measured using an individualized questionnaire and the standardized SF-12. RESULTS In the study population calculated probability of wearing the HB and RO was between 0.2 und 38.5% (95% confidence interval). No volunteer wore the SO orthosis for the predefined time. The SO and RO each displayed high subjective stabilization, while the RO was more often associated with side effects like skin pressure marks than the SO. The need for rework due to discomfort was mainly necessary with the RO. We observed no substantial differences in feeling compression and sweating. Noteworthy, eight of 12 subjects complained of uncomfortable sternal pressure due to the upper pad of the HB. The SF-12: scores ranged from 52.1 to 48.6 on the physical (PCS), and from 53.7 to 50.8 on the mental component score (MCS), demonstrating an influence on QoL. DISCUSSION AND CONCLUSIONS The design as well as the orthosis itself influence the compliance of wearing and exert a moderate negative, but acceptable impact on QoL. The SO appeared to correlate with the best overall compromise between comfort and subjective stabilization. Further investigations are necessary in patients with spinal diseases, for whom the effect of orthosis wearing may surpass the potential discomfort.
引用
收藏
页码:91 / 96
页数:6
相关论文
共 50 条
  • [21] Lecture versus standardized patient interaction in the surgical clerkship: a randomized prospective cross-over study
    Carter, MB
    Wesley, G
    Larson, GM
    AMERICAN JOURNAL OF SURGERY, 2006, 191 (02): : 262 - 267
  • [22] Selective intubation with endotracheal tube introducer in difficult airway: A randomized, prospective, cross-over study
    Ozerol, Hakan
    Sanci, Emre
    Karakayali, Onur
    Aydin, Erdem
    Halhalli, Huseyin Cahit
    TURKISH JOURNAL OF EMERGENCY MEDICINE, 2021, 21 (04): : 205 - 209
  • [23] Time needed to perform intermittent catheterization in adults with spinal cord injury: A pilot randomized controlled cross-over trial
    Gopalakrishnan, Karthik
    Nielsen, Nick Fabrin
    Ramirez, Andrea L.
    Sorensen, Jeppe
    Walter, Matthias
    Krassioukov, Andrei, V
    CONTINENCE REPORTS, 2022, 2
  • [24] Modeling the effect of stress on vaping behavior among young adults: A randomized cross-over pilot study
    Pericot-Valverde, Irene
    Heo, Moonseong
    Litwin, Alain H.
    Niu, Jiajing
    Gaalema, Diann E.
    DRUG AND ALCOHOL DEPENDENCE, 2021, 225
  • [25] Hormonal response after masturbation in young healthy men – a randomized controlled cross-over pilot study
    Eduard Isenmann
    Moritz Schumann
    Hannah L. Notbohm
    Ulrich Flenker
    Philipp Zimmer
    Basic and Clinical Andrology, 31
  • [26] Intradialytic isometric handgrip exercise does not cause hemodynamic instability: A randomized,cross-over, pilot study
    Ribeiro, Heitor S.
    Cunha, Vinicius A.
    Baiao, Victor M.
    Almeida, Lucas S.
    Dourado, Gustavo I.
    Carvalho, Helton L.
    Duarte, Marvery P.
    Inda-Filho, Antonio
    Viana, Joao L.
    Nobrega, Otavio T.
    Ferreira, Aparecido P.
    THERAPEUTIC APHERESIS AND DIALYSIS, 2021, 25 (03) : 282 - 289
  • [27] Adaptive mechanical ventilation with automated minimization of mechanical power-a pilot randomized cross-over study
    Becher, Tobias
    Adelmeier, Anna
    Frerichs, Inez
    Weiler, Norbert
    Schaedler, Dirk
    CRITICAL CARE, 2019, 23 (01): : 338
  • [28] Hormonal response after masturbation in young healthy men - a randomized controlled cross-over pilot study
    Isenmann, Eduard
    Schumann, Moritz
    Notbohm, Hannah L.
    Flenker, Ulrich
    Zimmer, Philipp
    BASIC AND CLINICAL ANDROLOGY, 2021, 31 (01)
  • [29] CIPROFLOXACIS AS PROPHYLAXIS FOR URINARY-TRACT INFECTION - PROSPECTIVE, RANDOMIZED, CROSS-OVER, PLACEBO-CONTROLLED STUDY IN PATIENTS WITH SPINAL-CORD
    BIERINGSORANSEN, F
    HOIBY, N
    NORDENBO, A
    RAVNBORG, M
    BRUUM, B
    RATH, V
    JOURNAL OF UROLOGY, 1994, 151 (04): : 1032 - 1032
  • [30] Moderate vision impairment to hip motion during vertical jumps: A pilot randomized cross-over study
    Zhu, Chengyuan
    Li, Xue
    Baker, Julien S.
    Shao, Shirui
    Gu, Yaodong
    MCB Molecular and Cellular Biomechanics, 2024, 21 (04):