Upper and Lower Tear Menisci in the Diagnosis of Dry Eye

被引:128
作者
Shen, Meixiao [1 ]
Li, Jianhua [1 ]
Wang, Jianhua [2 ]
Ma, Huixiang [1 ]
Cai, Chunyan [1 ]
Tao, Aizhu [1 ]
Yuan, Yimin [1 ]
Lu, Fan [1 ]
机构
[1] Wenzhou Med Coll, Sch Ophthalmol & Optometry, Wenzhou 325027, Zhejiang, Peoples R China
[2] Univ Miami, Bascom Palmer Eye Inst, Miami, FL USA
关键词
OPTICAL COHERENCE TOMOGRAPHY; ARTIFICIAL TEARS; OCULAR SURFACE; FILM; MENISCOMETRY; PARAMETERS; SICCA;
D O I
10.1167/iovs.08-2704
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To measure the upper and lower tear menisci in patients with aqueous tear deficiency (ATD) dry eye by real-time optical coherence tomography (OCT) and to determine the most effective meniscus variables for the diagnosis of dry eye. METHODS. Eyes of 48 pre-screened ATD patients were compared with those of 47 healthy subjects. Upper and lower tear menisci were imaged simultaneously by real-time OCT immediately after blinking. The height, radius, and cross-sectional area of upper and lower tear menisci were obtained. RESULTS. The tear meniscus radius, height, and cross-sectional area were significantly smaller in patients with dry eye than in healthy subjects (P < 0.01). The lower tear meniscus variables were higher than the upper menisci (P < 0.01) in normal subjects; however, no significant differences between menisci were found in ATD patients. In both groups, the upper and lower tear meniscus variables were strongly correlated with each other. Good dry eye diagnostic accuracies were obtained with cutoff values for an abnormal lower tear meniscus radius (LTMR) of 182 mu m and a lower tear meniscus height (LTMH) of 164 mu m. The LTMR diagnostic sensitivity and specificity were 0.92 and 0.87, respectively. The LTMH diagnostic sensitivity and specificity were 0.92 and 0.90. CONCLUSIONS. Upper tear meniscus variables in ATD patients were assessed by real-time OCT. The tear meniscus was smaller in ATD patients than in healthy subjects. LTMR and LTMH may have potential in the diagnosis of ATD. (Invest Ophthalmol Vis Sci. 2009; 50: 2722-2726) DOI: 10.1167/iovs.08-2704
引用
收藏
页码:2722 / 2726
页数:5
相关论文
共 30 条
[11]   A standardized visual scale for evaluation of tear fluorescein clearance [J].
Macri, A ;
Rolando, M ;
Pflugfelder, S .
OPHTHALMOLOGY, 2000, 107 (07) :1338-1343
[12]   Tear meniscus measurement in the diagnosis of dry eye [J].
Mainstone, JC ;
Bruce, AS ;
Golding, TR .
CURRENT EYE RESEARCH, 1996, 15 (06) :653-661
[13]  
McMonnies C W, 1987, J Am Optom Assoc, V58, P296
[14]  
MISHIMA S., 1966, INVEST OPHTHALMOL, V5, P264
[15]  
Nelson JD, 1998, ADV EXP MED BIOL, V438, P1
[16]   Frequency of dry eye diagnostic test procedures used in various modes of ophthalmic practice [J].
Nichols, KK ;
Nichols, JJ ;
Zadnik, K .
CORNEA, 2000, 19 (04) :477-482
[17]   The height and radius of the tear meniscus and methods for examining these parameters [J].
Oguz, H ;
Yokoi, N ;
Kinoshita, S .
CORNEA, 2000, 19 (04) :497-500
[18]   Effect of blinking on tear dynamics [J].
Palakuru, Jayachandra R. ;
Wang, Jianhua ;
Aquavella, James V. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (07) :3032-3037
[19]  
Patel S, 2001, J REFRACT SURG, V17, P17
[20]   Real-time optical coherence tomography of the anterior segment at 1310 nm [J].
Radhakrishnan, S ;
Rollins, AM ;
Roth, JE ;
Yazdanfar, S ;
Westphal, V ;
Bardenstein, DS ;
Izatt, JA .
ARCHIVES OF OPHTHALMOLOGY, 2001, 119 (08) :1179-1185