Mechanical properties and microstructure of glass fiber and polypropylene fiber reinforced concrete: An experimental study

被引:195
作者
Yuan, Zhu [1 ]
Jia, Yanmin [1 ]
机构
[1] Northeast Forestry Univ, Sch Civil Engn, Harbin 150040, Peoples R China
基金
黑龙江省自然科学基金;
关键词
Fiber-reinforced concrete; Glass fiber; Polypropylene fiber; Mechanical properties; Full curve of water absorption; Microstructure; HIGH-STRENGTH CONCRETE; HIGH-PERFORMANCE CONCRETE; FLY-ASH; CEMENTITIOUS COMPOSITES; DURABILITY PROPERTIES; EARLY AGE; BEHAVIOR; STEEL; BASALT; SILICA;
D O I
10.1016/j.conbuildmat.2020.121048
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results of a comprehensive experimental work investigating the effect of glass fiber (GF) and polypropylene fiber (PPF) on the mechanical and microstructural properties of concrete as a function of the water/binder ratio and fiber content. Different water/binder ratios (0.30 and 0.35), GF and PPF contents (0.45, 0.90, and 1.35% by volume fractions), and curing times (7 and 28 d) were used during the experiment to prepare the concrete specimens. The compressive, four-point flexural, and splitting tensile strengths and the full curves of water absorption of the glass-fiber-reinforced concrete (GFRC) and polypropylene-fiber-reinforced concrete (PPFRC) were obtained. The strength differences and water absorption properties of GFRC/PPFRC were analyzed in depth. Scanning electron microscope observation was undertaken to analyze the mechanism of the water/binder ratio and fiber effects. The results showed that the water/binder ratio can affect the optimal fiber content. When discussing the effect of fibers on the improvement of concrete mechanical or microstructural properties, the influence of the water/binder ratio should be considered. The improvement effect of GF on water absorption was significantly superior to that of PPF. When the water/binder ratio was 0.30, the water absorption of GFRC and PPFRC tended to be stable as the test proceeded, while when the water/binder ratio increased to 0.35, the water absorption of the GFRC and PPFRC with the highest fiber dosage still increased with the prolongation of testing time. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:13
相关论文
共 61 条
[1]   Effects of high temperatures on mechanical behavior of high strength concrete reinforced with high performance synthetic macro polypropylene (HPP) fibres [J].
Abaeian, Reza ;
Behbahani, Hamid Pesaran ;
Moslem, Shahram Jalali .
CONSTRUCTION AND BUILDING MATERIALS, 2018, 165 :631-638
[2]   Mechanical and durability properties of high-strength concrete containing steel and polypropylene fibers [J].
Afroughsabet, Vahid ;
Ozbakkaloglu, Togay .
CONSTRUCTION AND BUILDING MATERIALS, 2015, 94 :73-82
[3]  
[Anonymous], 552011 CS JGJ
[4]  
[Anonymous], 2015, D5550-6
[5]  
[Anonymous], 500812002 CS GBT
[6]   Effects of basalt and glass chopped fibers addition on fracture energy and mechanical properties of ordinary concrete: CMOD measurement [J].
ArsIan, Mehmet Emin .
CONSTRUCTION AND BUILDING MATERIALS, 2016, 114 :383-391
[7]  
ASTM, 2013, ASTM-C642-13
[8]   Influence of polypropylene fiber geometry on plastic shrinkage cracking in concrete [J].
Banthia, N ;
Gupta, R .
CEMENT AND CONCRETE RESEARCH, 2006, 36 (07) :1263-1267
[9]   Cracking control of concretes modified with short AR-glass fibers at early age.: Experimental results on standard concrete and SCC [J].
Barluenga, G. ;
Hernandez-Olivares, F. .
CEMENT AND CONCRETE RESEARCH, 2007, 37 (12) :1624-1638
[10]   Application of high performance polypropylene fibers in concrete lining of water tunnels [J].
Behfarnia, Kiachehr ;
Behravan, Amir .
MATERIALS & DESIGN, 2014, 55 :274-279