Sensitive and Environmentally Friendly Field Analysis of Waterborne Arsenic by Electrochemical Hydride Generation Microplasma Optical Emission Spectrometry

被引:14
作者
He, Liangbo [1 ]
Lin, Yao [2 ]
Su, Yubin [1 ]
Li, Yuanyuan [1 ]
Deng, Yurong [1 ]
Zheng, Chengbin [1 ]
机构
[1] Sichuan Univ, Coll Chem, Key Lab Green Chem & Technol MOE, Chengdu 610064, Sichuan, Peoples R China
[2] Sichuan Univ, West China Sch Basic Med Sci & Forens Med, Chengdu 610041, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
DIELECTRIC-BARRIER DISCHARGE; ATOMIC-ABSORPTION-SPECTROMETRY; CHEMICAL-VAPOR GENERATION; GLOW-DISCHARGE; FLUORESCENCE SPECTROMETRY; MECHANISTIC ASPECTS; ELEMENTAL ANALYSIS; FORMING ELEMENTS; LOW-TEMPERATURE; PLASMA;
D O I
10.1021/acs.analchem.2c03784
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To avoid polluting the environment, it is desirable to develop methods consuming as few chemicals as possible for field elemental analysis. In this work, a lithium-ion battery supplied, compact handheld optical emission spectrometer (OES) (0.3 kg, length 18 cm x width 5 cm x height 10 cm) was fabricated for the sensitive field analysis of waterborne arsenic by utilizing electro-chemical hydride generation (ECHG) and miniaturized ballpoint discharge (mu PD) as sample introduction means and excitation source, respectively. The high ECHG efficiency of arsenic was obtained using a superior cathode of Fe@PbO/Pb and the generated arsine was separated from an aqueous phase and further swept to the mu PD microplasma for detection. It is worth noting that the Fe@PbO/Pb cathode not only retains advantages of large specific surface area, robust stability, and excellent reproducibility for the ECHG of arsenic but also accomplishes the preconcentration of As(III), thus improving the kinetics of the surface chemistry at the cathode, alleviating the corrosion of the electrode, and minimizing the release of Pb. A limit of detection of 1.0 mu g L-1 was obtained with a relative standard deviation of 4.2% for 20 mu g L-1 As(III). Owing to the advantages of ECHG and mu PD-OES, the system retains a promising potential for the sensitive, cost-effective, and environmentally friendly field analysis of waterborne arsenic.
引用
收藏
页码:17514 / 17521
页数:8
相关论文
共 52 条
[31]   Effectiveness and reliability of arsenic field testing kits: Are the million dollar screening projects effective or not? [J].
Rahman, MM ;
Mukherjee, D ;
Sengupta, MK ;
Chowdhury, UK ;
Lodh, D ;
Chanda, CR ;
Roy, S ;
Selim, M ;
Quamruzzaman, Q ;
Milton, AH ;
Shahidullah, SM ;
Rahman, MT ;
Chakraborti, D .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (24) :5385-5394
[32]   Evaluation of arsenic field test kits for drinking water: Recommendations for improvement and implications for arsenic affected regions such as Bangladesh [J].
Reddy, Raghav R. ;
Rodriguez, Grace D. ;
Webster, Tara M. ;
Abedin, Md Joynul ;
Karim, Md Rezaul ;
Raskin, Lutgarde ;
Hayes, Kim F. .
WATER RESEARCH, 2020, 170
[33]   Electrochemical Arsine Generators for Arsenic Determination [J].
Shen, Hong ;
Dasgupta, Purnendu K. .
ANALYTICAL CHEMISTRY, 2014, 86 (15) :7705-7711
[34]   Nano-Enabled sensors for detection of arsenic in water [J].
Thakkar, Shalini ;
Dumee, Ludovic F. ;
Gupta, Manish ;
Singh, Braj Raj ;
Yang, Wenrong .
WATER RESEARCH, 2021, 188
[35]   Compact glow discharge for the elemental analysis of aqueous samples [J].
Webb, Michael R. ;
Andrade, Francisco J. ;
Hieftje, Gary M. .
ANALYTICAL CHEMISTRY, 2007, 79 (20) :7899-7905
[36]   Comparison of in vitro models in a mice model and investigation of the changes in Pb speciation during Pb bioavailability assessments [J].
Yan, Kaihong ;
Dong, Zhaomin ;
Naidu, Ravi ;
Liu, Yanju ;
Li, Yeling ;
Wijayawardena, Ayanka ;
Sanderson, Peter ;
Li, Hongbo ;
Ma, Lena Q. .
JOURNAL OF HAZARDOUS MATERIALS, 2020, 388
[37]   Highly Sensitive Determination of Arsenic and Antimony Based on an Interrupted Gas Flow Atmospheric Pressure Glow Discharge Excitation Source [J].
Yang, Chun ;
Chan, George C. -Y. ;
He, Dong ;
Liu, Zhifu ;
Deng, Qisi ;
Zheng, Hongtao ;
Hu, Shenghong ;
Zhu, Zhenli .
ANALYTICAL CHEMISTRY, 2019, 91 (03) :1912-1919
[38]   Battery-Operated Atomic Emission Analyzer for Waterborne Arsenic Based on Atmospheric Pressure Glow Discharge Excitation Source [J].
Yang, Chun ;
He, Dong ;
Zhu, Zhenli ;
Peng, Huan ;
Liu, Zhifu ;
Wen, Guojun ;
Bai, Jianghao ;
Zheng, Hongtao ;
Hu, Shenghong ;
Wang, Yanxin .
ANALYTICAL CHEMISTRY, 2017, 89 (06) :3694-3701
[39]   Low temperature hydrogen plasma assisted chemical vapor generation for Atomic Fluorescence Spectrometry [J].
Yang, Meng ;
Xue, Jiao ;
Li, Ming ;
Han, Guojun ;
Xing, Zhi ;
Zhang, Sichun ;
Zhang, Xinrong .
TALANTA, 2014, 126 :1-7
[40]   Miniaturization of inductively coupled plasma sources [J].
Yin, Y ;
Messier, J ;
Hopwood, JA .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 1999, 27 (05) :1516-1524