Dynamic measurement of the corneal tear film with a Twyman-Green interferometer

被引:1
|
作者
Micali, Jason D. [1 ]
Greivenkamp, John E. [1 ]
Primeau, Brian C. [1 ]
机构
[1] Univ Arizona, Coll Opt Sci, Tucson, AZ 85721 USA
来源
INTERFEROMETRY XVII: ADVANCED APPLICATIONS | 2014年 / 9204卷
关键词
Tear film; fluid layer; interferometry; contact lens; corneal topography;
D O I
10.1117/12.2064431
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An interferometer for measuring dynamic properties of the in vivo tear film on the human cornea has been developed. The system is a near-infrared instantaneous phase-shifting Twyman-Green interferometer. The laser source is a 785 nm solid-state laser; the system has been carefully designed and calibrated to ensure that the system operates at eye safe levels. Measurements are made over a 6 mm diameter on the cornea. Successive frames of interferometric height measurements are combined to produce movies showing both the quantitative and qualitative changes in the topography of the tear film surface and structure. To date, measurement periods of up to 120 seconds at 28.6 frames per second have been obtained. Several human subjects have been examined using this system, demonstrating a surface height resolution of 25 nm and spatial resolution of 6 mu m. Examples of features that have been observed in these in preliminary studies of the tear film include: post-blink disruption, evolution, and stabilization of the tear film; tear film artifacts generated by blinking; tear film evaporation and break-up; and the propagation of foreign objects in the tear film. This paper discusses the interferometer design and presents results from in vivo measurements.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Dynamic measurement of the corneal tear film with a Twyman-Green interferometer
    Micali, Jason D.
    Greivenkamp, John E.
    Primeau, Brian C.
    JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (05)
  • [2] Application of Twyman-Green interferometer for evaluation of in vivo breakup characteristic of the human tear film
    Licznerski, TJ
    Kasprzak, HT
    Kowalik, W
    JOURNAL OF BIOMEDICAL OPTICS, 1999, 4 (01) : 176 - 182
  • [3] TWYMAN-GREEN INTERFEROMETER FOR TESTING MICROSPHERES
    SCHWIDER, J
    FALKENSTORFER, O
    OPTICAL ENGINEERING, 1995, 34 (10) : 2972 - 2975
  • [4] Estimation of an uncertainty budget and performance measurement for a dual-wavelength Twyman-Green interferometer
    Ibrahim, Dahi Ghareab Abdelsalam
    JOURNAL OF MICROSCOPY, 2021, 282 (03) : 224 - 238
  • [5] Dual interferometer for dynamic measurement of corneal topography
    Micali, Jason D.
    Greivenkamp, John E.
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (08)
  • [6] Interferometer for measuring the dynamic surface topography of a human tear film
    Primeau, Brian C.
    Greivenkamp, John E.
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES V, 2012, 8215
  • [7] Optical image processing using phase reversal Twyman-Green interferometer
    Rao, VV
    Mohan, NK
    VISUAL INFORMATION PROCESSING XI, 2002, 4736 : 184 - 188
  • [8] Fringe localization in the Twyman-Green Interferometer using extended monochromatic sources
    Schwider, Johannes
    INTERFEROMETRY XIII: TECHNIQUES AND ANALYSIS, 2006, 6292
  • [9] Long gauge block measurements based on a Twyman-Green interferometer and three stabilized lasers
    Haitjema, H
    Kotte, GJ
    RECENT DEVELOPMENTS IN OPTICAL GAUGE BLOCK METROLOGY, 1998, 3477 : 25 - 34
  • [10] Static and dynamic measurements of active MEMS by Twyman-Green interferometry: case of AIN-based microactuators
    Gorecki, C.
    Andrei, A.
    Jozwik, M.
    Krupa, K.
    Dogheche, K.
    Balandras, S.
    Hirsinger, L.
    Delobelle, P.
    INTERFEROMETRY XIII: APPLICATIONS, 2006, 6293