The Analysis Performance of a Grid-Connected 8.2 kWp Photovoltaic System in the Patagonia Region

被引:16
作者
Vidal, Humberto [1 ]
Rivera, Marco [2 ]
Wheeler, Patrick [3 ]
Vicencio, Nicolas [2 ]
机构
[1] Univ Magallanes, Fac Engn, CERE, Punta Arenas 6200000, Chile
[2] Univ Talca, Fac Engn, Dept Elect Engn, Campus Cur 3344158, Talca, Chile
[3] Univ Nottingham, Fac Engn, Nottingham NG7 2RD, England
关键词
photovoltaic system; solar energy; grid connected; PVSyst software; PV SYSTEM; SIMULATION; DESIGN; ENERGY; KW(P); PLANT;
D O I
10.3390/su12219227
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Solar PV structures for locations at high latitudes in the Northern and Southern Hemispheres are increasingly in the spotlight. The work reported in this paper analyses the behaviour of a grid-connected 8.2 kWp photovoltaic system to either feed on-site electrical loads (a public institution, Corporacion Nacional Forestal (CONAF), located 5.5 km south of Punta Arenas, lat. 53 degrees S) or to feed into the electrical grid when the photovoltaic system generation is higher than the on-site load demand. The system simulation uses the PVSyst software with Meteonorm derived and measured climate information sets (ambient temperature, solar irradiation and wind speed). The agreement between the simulated and measured energy yield is analysed including the evaluation of the optimal generation energy of the PV array, the energy that is fed into the network, the performance ratio, and the normalised energy generation per installed kWp. The PV system considered in this work generates 7005.3 kWh/year, out of which only 6778 kWh/year are injected into the grid. The measured annual performance ratio is around 89%. The normalised productions of the inverter output or final system yield, i.e., useful energy, is 3.6 kWh/kWp/day. The measured annual average capacity factor obtained from this study is 15.1%. These performance parameters will encourage greater use of photovoltaic technology in the Chilean Patagonia region.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 36 条
[1]   Techno-economic analysis of a 2.1 kW rooftop photovoltaic-grid-tied system based on actual performance [J].
Adaramola, Muyiwa S. .
ENERGY CONVERSION AND MANAGEMENT, 2015, 101 :85-93
[2]   Preliminary assessment of a small-scale rooftop PV-grid tied in Norwegian climatic conditions [J].
Adaramola, Muyiwa S. ;
Vagnes, Emil E. T. .
ENERGY CONVERSION AND MANAGEMENT, 2015, 90 :458-465
[3]   A Comparative Study of Supercapacitor-Based STATCOM in a Grid-Connected Photovoltaic System for Regulating Power Quality Issues [J].
Afzal, Muhammad Moin ;
Khan, Muhammad Adil ;
Hassan, Muhammad Arshad Shehzad ;
Wadood, Abdul ;
Uddin, Waqar ;
Hussain, S. ;
Rhee, Sang Bong .
SUSTAINABILITY, 2020, 12 (17)
[4]   Energetic, economic and environmental (3E) analyses and LCOE estimation of three technologies of PV grid-connected systems under different climates [J].
Allouhi, A. ;
Saadani, R. ;
Buker, M. S. ;
Kousksou, T. ;
Jamil, A. ;
Rahmoune, M. .
SOLAR ENERGY, 2019, 178 :25-36
[5]   Grid-connected PV systems installed on institutional buildings: Technology comparison, energy analysis and economic performance [J].
Allouhi, A. ;
Saadani, R. ;
Kousksou, T. ;
Saidur, R. ;
Jamil, A. ;
Rahmoune, M. .
ENERGY AND BUILDINGS, 2016, 130 :188-201
[6]  
[Anonymous], **NON-TRADITIONAL**
[7]  
[Anonymous], 2019, PV SYST USER MANUAL
[8]  
[Anonymous], 1998, PHOT SYST PERF MON G
[9]   Measured performance of a 1.72 kW rooftop grid connected photovoltaic system in Ireland [J].
Ayompe, L. M. ;
Duffy, A. ;
McCormack, S. J. ;
Conlon, M. .
ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (02) :816-825
[10]   Performance investigation of a PV system connected to the grid [J].
Baghdadi, Ilham ;
El Yaakoubi, Ali ;
Attari, Kamal ;
Leemrani, Zouhir ;
Asselman, Adel .
11TH INTERNATIONAL CONFERENCE INTERDISCIPLINARITY IN ENGINEERING, INTER-ENG 2017, 2018, 22 :667-674