In vivo MRI mapping of iron oxide-labeled stem cells transplanted in the heart

被引:8
作者
Ruggiero, A. [1 ]
Guenoun, J. [1 ]
Smit, H. [2 ,3 ]
Doeswijk, G. N. [1 ]
Klein, S. [2 ,3 ]
Krestin, G. P. [1 ]
Kotek, G. [1 ]
Bernsen, M. R. [1 ,4 ]
机构
[1] Erasmus MC, Dept Radiol, Rotterdam, Netherlands
[2] Erasmus MC, Biomed Imaging Grp Rotterdam, Dept Med Informat, Rotterdam, Netherlands
[3] Erasmus MC, Biomed Imaging Grp Rotterdam, Dept Radiol, Rotterdam, Netherlands
[4] Erasmus MC, Dept Nucl Med, Rotterdam, Netherlands
关键词
Magnetic resonance imaging; stem cell tracking; R2; Mapping; ACUTE MYOCARDIAL-INFARCTION; BONE-MARROW-CELLS; QUANTIFICATION; FERUCARBOTRAN; NANOPARTICLES; SURVIVAL; THERAPY; MATRIX; EDEMA; 1.5T;
D O I
10.1002/cmmi.1582
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In various stem cell therapy approaches poor cell survival has been recognized as an important factor limiting therapeutic efficacy. Therefore noninvasive monitoring of cell fate is warranted for developing clinically effective stem cell therapy. In this study we investigated the use of voxel-based R-2 mapping as a tool to monitor the fate of iron oxide-labeled cells in the myocardium. Mesenchymal stem cells were transduced with the luciferase gene, labeled with ferumoxide particles and injected in the myocardium of healthy rats. Cell fate was monitored over a period of 8weeks by bioluminescence and quantitative magnetic resonance imaging. Bioluminescence signal increased during the first week followed by a steep decrease to undetectable levels during the second week. MR imaging showed a sharp increase in R-2 values shortly after injection at the injection site, followed by a very gradual decrease of R-2 over a period of 8weeks. No difference in the appearances on R-2-weighted images was observed between living and dead cells over the entire time period studied. No significant correlation between the bioluminescence optical data and R-2 values was observed and quantitative R-2 mapping appeared not suitable for the in vivo assessment of stem cell. These results do not follow previous in vitro reports where it was proposed that living cells may be distinguished from dead cells on the basis of the R-2 relaxivities (intracellular and extracellular iron oxides). Cell proliferation, cell migration, cell death, extracellular superparamagnetic iron oxide dispersion and aggregation exhibit different relaxivities. In vivo these processes happen simultaneously, making quantification very complex, if not impossible. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:487 / 494
页数:8
相关论文
共 40 条
[1]   ACUT2E TSE-SSFP:: A hybrid method for T2-weighted Imaging of edema in the heart [J].
Aletras, Anthony H. ;
Kellman, Peter ;
Derbyshire, J. Andrew ;
Arai, Andrew E. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (02) :229-235
[2]   Iron-oxide Labeling and outcome of transplanted mesenchymal stem cells in the infarcted myocardium [J].
Amsalem, Yoram ;
Mardor, Yael ;
Feinberg, Micha S. ;
Landa, Natalie ;
Miller, Liron ;
Daniels, Dianne ;
Ocherashvilli, Aharon ;
Holbova, Radka ;
Yosef, Orna ;
Barbash, Israel M. ;
Leor, Jonathan .
CIRCULATION, 2007, 116 (11) :I38-I45
[3]   Magnetic resonance imaging and confocal microscopy studies of magnetically labeled endothelial progenitor cells trafficking to sites of tumor angiogenesis [J].
Arbab, Ali S. ;
Frenkel, Victor ;
Pandit, Sunil D. ;
Anderson, Stasia A. ;
Yocum, Gene T. ;
Bur, Monica ;
Khuu, Hanh M. ;
Read, Elizabeth J. ;
Frank, Joseph A. .
STEM CELLS, 2006, 24 (03) :671-678
[4]  
Atalay MK, 2001, MAGNET RESON MED, V45, P341, DOI 10.1002/1522-2594(200102)45:2<341::AID-MRM1043>3.0.CO
[5]  
2-Q
[6]   Labelling of mammalian cells for visualisation by MRI [J].
Bernsen, Monique R. ;
Moelker, Amber D. ;
Wielopolski, Piotr A. ;
van Tiel, Sandra T. ;
Krestin, Gabriel P. .
EUROPEAN RADIOLOGY, 2010, 20 (02) :255-274
[7]   How to quantify iron in an aqueous or biological matrix: a technical note [J].
Boutry, Sebastien ;
Forge, Delphine ;
Burtea, Carmen ;
Mahieu, Isabelle ;
Murariu, Oltea ;
Laurent, Sophie ;
Elst, Luce Vander ;
Muller, Robert N. .
CONTRAST MEDIA & MOLECULAR IMAGING, 2009, 4 (06) :299-304
[8]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[9]   Cardiovascular Molecular Imaging Focus on Clinical Translation [J].
Chen, Ian Y. ;
Wu, Joseph C. .
CIRCULATION, 2011, 123 (04) :425-443
[10]   Comparison of Optical Bioluminescence Reporter Gene and Superparamagnetic Iron Oxide MR Contrast Agent as Cell Markers for Noninvasive Imaging of Cardiac Cell Transplantation [J].
Chen, Ian Y. ;
Greve, Joan M. ;
Gheysens, Olivier ;
Willmann, Juergen K. ;
Rodriguez-Porcel, Martin ;
Chu, Pauline ;
Sheikh, Ahmad Y. ;
Faranesh, Anthony Z. ;
Paulmurugan, Ramasamy ;
Yang, Phillip C. ;
Wu, Joseph C. ;
Gambhir, Sanjiv S. .
MOLECULAR IMAGING AND BIOLOGY, 2009, 11 (03) :178-187