A review of artificial roughness geometries employed in solar air heaters

被引:76
作者
Singh, Inderjeet [1 ]
Singh, Sukhmeet [2 ]
机构
[1] Punjab Agr Univ, Dept Mech Engn, Ludhiana 141004, Punjab, India
[2] Punjab Agr Univ, Sch Renewable Energy Engn, Ludhiana 141004, Punjab, India
关键词
Solar air heater; Artificial roughness; Heat transfer; CFD; Reynolds number; Thermohydraulic; FRICTION FACTOR CORRELATIONS; THERMOHYDRAULIC PERFORMANCE ANALYSIS; TRANSVERSE RIB ROUGHNESS; V-DOWN RIBS; ABSORBER PLATE; NUSSELT NUMBER; FLUID-FLOW; TRANSFER ENHANCEMENT; ROUGHENED DUCT; GAP;
D O I
10.1016/j.rser.2018.04.108
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Enhancement of heat transfer in the solar air heater ducts can be achieved by breaking laminar sub-layer near the absorbing surface and can be efficiently done by employing ribs as roughness elements. However, this gain is accomplished at the expense of increase in pressure drop. This paper presents the detailed review of various investigations made on artificial roughness geometries summarizing their outcomes. Attempt have been made to study the effect of various influencing roughness and flow parameters on the thermal and hydraulic performance of solar air heater through the flow visualization.
引用
收藏
页码:405 / 425
页数:21
相关论文
共 50 条
[1]   Experimental investigation on heat-transfer enhancement due to a gap in an inclined continuous rib arrangement in a rectangular duct of solar air heater [J].
Aharwal, K. R. ;
Gandhi, B. K. ;
Saini, J. S. .
RENEWABLE ENERGY, 2008, 33 (04) :585-596
[2]   A critical review on artificial roughness provided in rectangular solar air heater duct [J].
Alam, Tabish ;
Kim, Man-Hoe .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 69 :387-400
[3]   Experimental investigations on heat transfer and frictional characteristics of a turbulator roughened solar air heater duct [J].
Bopche, Santosh B. ;
Tandale, Madhukar S. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (11-12) :2834-2848
[4]   Performance analysis of solar air heater duct roughened with multigap V-down ribs combined with staggered ribs [J].
Deo, Narinderpal Singh ;
Chander, Subhash ;
Saini, J. S. .
RENEWABLE ENERGY, 2016, 91 :484-500
[5]  
Duffie J.A., 1994, Solar Engineering of Thermal Processes
[6]   A review of CFD methodology used in literature for predicting thermo-hydraulic performance of a roughened solar air heater [J].
Gawande, Vipin B. ;
Dhoble, A. S. ;
Zodpe, D. B. ;
Chamoli, Sunil .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 54 :550-605
[7]   HEAT AND FLUID-FLOW IN RECTANGULAR SOLAR AIR HEATER DUCTS HAVING TRANSVERSE RIB ROUGHNESS ON ABSORBER PLATES [J].
GUPTA, D ;
SOLANKI, SC ;
SAINI, JS .
SOLAR ENERGY, 1993, 51 (01) :31-37
[8]   Heat transfer and friction factor correlations for a solar air heater duct roughened artificially with broken arc ribs [J].
Hans, V. S. ;
Gill, R. S. ;
Singh, Sukhmeet .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2017, 80 :77-89
[9]   Heat transfer and friction factor correlations for a solar air heater duct roughened artificially with multiple v-ribs [J].
Hans, V. S. ;
Saini, R. P. ;
Saini, J. S. .
SOLAR ENERGY, 2010, 84 (06) :898-911
[10]   Performance of artificially roughened solar air heaters-A review [J].
Hans, Vishavjeet Singh ;
Saini, R. P. ;
Saini, J. S. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2009, 13 (08) :1854-1869