Posterior capsule folds and removal of ophthalmic viscosurgical devices

被引:3
|
作者
Blomquist, PH [1 ]
Kelly, JL [1 ]
机构
[1] Univ Texas, SW Med Ctr, Dept Ophthalmol, Dallas, TX 75390 USA
来源
关键词
D O I
10.1016/S0886-3350(01)01312-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the relationship between posterior capsule folds and an ophthalmic viscosurgical device (OVD) during cataract surgery. Setting: Parkland Memorial Hospital, Dallas, Texas, USA. Methods: A prospective observational study of 91 consecutive uneventful cataract extractions by phacoemulsification was performed. The presence or absence of posterior capsule folds was noted immediately after intraocular lens (IOL) implantation and after OVD removal. Results: Posterior capsule folds were present in 21 of 49 cases (43%) with an MA60BM lens (Alcon Laboratories) and in 1 of 42 cases (2%) with an SA30AL lens. In the MA60BM group with folds, the folds were noted before OVD removal in 14 cases and after OVD removal in 16 cases. There was no significant difference in age, sex, axial length, horizontal corneal diameter, or IOL power between groups with and without posterior capsule folds. Conclusion: The presence of posterior capsule folds does not reliably signify the complete removal of OVDs.
引用
收藏
页码:1565 / 1567
页数:3
相关论文
共 50 条
  • [1] Ophthalmic viscosurgical devices
    Bissen-Miyajima, Hiroko
    CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (01) : 50 - 54
  • [2] Bimanual RetroIOL aspiration for complete removal of ophthalmic viscosurgical devices
    Dada, T
    Dada, VK
    Sethi, HS
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (04): : 852 - 852
  • [3] Endotoxins in ophthalmic viscosurgical devices
    Dick, HB
    Augustin, AJ
    Pakula, T
    Pfeiffer, N
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2003, 13 (02) : 176 - 184
  • [4] Maneuver to minimize zonular stress during removal of ophthalmic viscosurgical devices
    Dada, VK
    Sethi, HS
    Sharma, N
    Dada, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (05): : 1045 - 1046
  • [5] New terminology: Ophthalmic viscosurgical devices
    Arshinoff, S
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (05): : 627 - 628
  • [6] Prefilled syringes and usability of ophthalmic viscosurgical devices
    Shiba, Takuya
    Tsuneoka, Hiroshi
    CLINICAL OPHTHALMOLOGY, 2014, 8 : 1697 - 1702
  • [7] Silicone oil bubbles in ophthalmic viscosurgical devices
    Ohrstrom, A
    Behndig, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (03): : 389 - 389
  • [8] Detecting Endotoxin Contamination of Ophthalmic Viscosurgical Devices
    Buchen, Shelley Y.
    Calogero, Don
    Hilmantel, Gene
    Eydelman, Malvina B.
    OPHTHALMOLOGY, 2012, 119 (07) : E11 - E18
  • [9] Silicone oil bubbles in ophthalmic viscosurgical devices
    Lanzl, IM
    Merté, RL
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (12): : 2069 - 2069
  • [10] Influence of ophthalmic viscosurgical devices on intraoperative aberrometry
    Masket, Samuel
    Fram, Nicole R.
    Holladay, Jack T.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (07): : 990 - 994