Assessment of the in vivo biomechanical properties of the human uterine cervix in pregnancy using the aspiration test A feasibility study

被引:34
作者
Bauer, Margit [1 ]
Mazza, Edoardo [2 ,3 ,5 ]
Jabareen, Mahmood [2 ]
Sultan, Leila [4 ]
Bajka, Michael [4 ]
Lang, Uwe [1 ]
Zimmermann, Roland
Holzapfel, Gerhard A. [6 ]
机构
[1] Med Univ Graz, Dept Obstet & Gynecol, Graz, Austria
[2] Swiss Fed Inst Technol, Dept Mech & Proc Engn, Zurich, Switzerland
[3] Swiss Fed Labs Mat Testing & Res EMPA, Dubendorf, Switzerland
[4] Univ Zurich Hosp, Dept Obstet & Gynecol, Clin Obstet, Zurich, Switzerland
[5] Graz Univ Technol, Inst Biomech, A-8010 Graz, Austria
[6] Royal Inst Technol KTH, Dept Solid Mech, Sch Engn Sci, Stockholm, Sweden
关键词
Uterine cervix; Remodeling; Mechanical properties; Biomechanics; Aspiration device; In vivo; Pregnancy; Stiffness; LIGHT-INDUCED FLUORESCENCE; PRETERM LABOR; DELIVERY; WOMEN; RISK; INCOMPETENCE; CONTRACTIONS; MANAGEMENT; FREQUENCY; TISSUE;
D O I
10.1016/j.ejogrb.2009.02.025
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To date no diagnostic tool is yet available to objectively assess the in vivo biomechanical properties of the uterine cervix during gestation. Methods: We show the first clinical application of an aspiration device to assess the in vivo biomechanical properties of the cervix in pregnancy with the aim to describe the physiological biomechanical changes throughout gestation in order to eventually detect pregnant women at risk for cervical insufficiency (CI). Results: Out of 15 aspiration measurements, 12 produced valid results. The stiffness values were in the range between 0.013 and 0.068 bar/mm. The results showed a good reproducibility of the aspiration test. In our previous test series on non-pregnant cervices our repetitive measurements showed a standard deviation of > 20% compared to <+/- 10% to our data on pregnant cervices. Stiffness values are decreasing with gestational age which indicates a progressive softening of cervical tissue towards the end of pregnancy. Three pregnant women had two subsequent measurements within a time interval of four weeks. Decreasing stiffness values in the range of 20% were recorded. Discussion: This preliminary study on the clinical practicability of aspiration tests showed promising results in terms of reproducibility (reliability) and clinical use (feasibility). Ongoing studies will provide further insights on its usefulness in clinical practice and in the detection of substantial changes of the cervix in pregnancy indicative for threatened preterm birth or cervical insufficiency. (c) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:S77 / S81
页数:5
相关论文
共 25 条
[1]   Management of cervical weakness based on the measurement of cervical resistance index [J].
Anthony, George S. ;
Walker, Robert G. ;
Robins, James B. ;
Cameron, Alan D. ;
Calder, Andrew A. .
EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2007, 134 (02) :174-178
[2]   In vivo characterization of the mechanics of human uterine cervices [J].
Bauer, Margit ;
Mazza, Edoardo ;
Nava, Alessandro ;
Zeck, Willibald ;
Eder, Martina ;
Bajka, Michael ;
Cacho, Fernando ;
Lang, Uwe ;
Holzapfel, Gerhard A. .
REPRODUCTIVE BIOMECHANICS, 2007, 1101 :186-202
[3]   Frequency of uterine contractions in asymptomatic pregnant women with or without a short cervix on transvaginal ultrasound scan [J].
Berghella, V ;
Iams, JD ;
Newman, RB ;
MacPherson, C ;
Goldenberg, RL ;
Mueller-Heubach, E ;
Caritis, SN ;
Dombrowski, MP .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2004, 191 (04) :1253-1256
[4]   Natural history of cervical funneling in women at high risk for spontaneous preterm birth [J].
Berghella, Vincenzo ;
Owen, John ;
MacPherson, Cora ;
Yost, Nicole ;
Swain, Melissa ;
Dildy, Gary A., III ;
Miodovnik, Menachem ;
Langer, Oded ;
Sibai, Baha .
OBSTETRICS AND GYNECOLOGY, 2007, 109 (04) :863-869
[5]  
BISHOP EH, 1964, OBSTET GYNECOL, V24, P266
[6]   PROGNOSTIC VALUE OF CERVICAL DISTENSIBILITY INDEX MEASUREMENT IN THE OUTCOME OF PREGNANCIES WITH THREATENED PREMATURE LABOR [J].
CABROL, D ;
CARBONNE, B ;
JANNET, D ;
BATON, C ;
BONORIS, E ;
DUDZIK, W ;
LEHOUEZEC, R .
GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 1991, 32 (01) :28-32
[7]  
CABROL D, 1991, SEMIN PERINATOL, V15, P133
[8]   Uterine electromyography and light-induced fluorescence in the management of term and preterm labor [J].
Garfield, RE ;
Maul, H ;
Maner, W ;
Fittkow, C ;
Olson, G ;
Shi, L ;
Saade, GR .
JOURNAL OF THE SOCIETY FOR GYNECOLOGIC INVESTIGATION, 2002, 9 (05) :265-275
[9]   The cervix as a biomechanical structure [J].
House, M. ;
Socrate, S. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 28 (06) :745-749
[10]   Magnetic resonance imaging of the cervix during pregnancy: Effect of gestational age and prior vaginal birth [J].
House, M ;
O'Callaghan, M ;
Bahrami, S ;
Chelmow, D ;
Kini, J ;
Wu, D ;
Patz, S ;
Bhadelia, RA .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2005, 193 (04) :1554-1560