Increasing Efficiency of Parallel Imaging for 2D Multislice Acquisitions

被引:13
作者
Honal, Matthias [1 ]
Bauer, Simon [1 ]
Ludwig, Ute [1 ]
Leupold, Jochen [1 ]
机构
[1] Univ Hosp Freiburg, Dept Diagnost Radiol, D-79106 Freiburg, Germany
关键词
parallel imaging; multislice acquisitions; calibration; GRAPPA; TO-NOISE RATIO; IMAGES; SENSE;
D O I
10.1002/mrm.21818
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Parallel imaging algorithms require precise knowledge about the spatial sensitivity variation of the receiver coils to reconstruct images with full field of view (FOV) from undersampled Fourier encoded data. Sensitivity information must either be given a priori, or estimated from calibration data acquired along with the actual image data. In this study, two approaches are presented, which require very little or no additional data at all for calibration in two-dimensional multislice acquisitions. Instead of additional data, information from spatially adjacent slices is used to estimate coil sensitivity information, thereby increasing the efficiency of parallel imaging. The proposed approaches rely on the assumption that over a small range of slices, coil sensitivities vary smoothly in slice direction. Both methods are implemented as variants of the GRAPPA algorithm. For a given effective acceleration, superior image quality is achieved compared to the conventional GRAPPA method. For the latter calibration lines for coil weight computation must be acquired in addition to the undersampled k-spaces for coil weight computation, thus requiring higher k-space undersampling, that is, a higher reduction factor to achieve the same effective acceleration. The proposed methods are particularly suitable to speed up parallel imaging for clinical applications where the reduction factor is limited to two or three. Magn Reson Med 61:1459-1470, 2009. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:1459 / 1470
页数:12
相关论文
共 17 条
[1]  
BAUER S, 2007, P 10 JAHR DTSCH SEKT, P53
[2]   Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA) [J].
Breuer, FA ;
Kellman, P ;
Griswold, MA ;
Jakob, PM .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (04) :981-985
[3]  
CLINE HE, 2004, P 12 ANN M INT SOC M
[4]   Signal-to-noise measurements in magnitude images from NMR phased arrays [J].
Constantinides, CD ;
Atalar, E ;
McVeigh, ER .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (05) :852-857
[5]   Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters [J].
Dietrich, Olaf ;
Raya, Jose G. ;
Reeder, Scott B. ;
Reiser, Maximilian F. ;
Schoenberg, Stefan O. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (02) :375-385
[6]   Autocalibrated coil sensitivity estimation for parallel imaging [J].
Griswold, MA ;
Breuer, F ;
Blaimer, M ;
Kannengiesser, S ;
Heidemann, RM ;
Mueller, M ;
Nittka, M ;
Jellus, V ;
Kiefer, B ;
Jakob, PM .
NMR IN BIOMEDICINE, 2006, 19 (03) :316-324
[7]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[8]  
MOELLER S, 2004, P 12 ANN M INT SOC M
[9]   Ultimate intrinsic signal-to-noise ratio for parallel MRI: Electromagnetic field considerations [J].
Ohliger, MA ;
Grant, AK ;
Sodickson, DK .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) :1018-1030
[10]  
Pruessmann KP, 1999, MAGNET RESON MED, V42, P952, DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO