A novel RF resonator using microstrip transmission line for human body MRI at 3T

被引:0
|
作者
Son, Hyeok-Woo [1 ]
Cho, Young-Ki [1 ]
Yoo, Hyungsuk [2 ]
机构
[1] Kyungpook Natl Univ, Sch Elect Engn, 80 Daehakro, Taegu 702701, South Korea
[2] Univ Ulsan, Dept Biomed Engn, Ulsan 680749, South Korea
关键词
HIGH-FIELD MRI; COIL;
D O I
暂无
中图分类号
TN [电子技术、通信技术];
学科分类号
0809 ;
摘要
A square-slots loaded (SSL) radio frequency (RF) resonator using microstrip transmission line (MTL) is designed for a human body 3T MRI. The SSL RF resonator shows greater penetrated RF magnetic fields near the center of the phantom than traditional RF resonators using MTL. A multichannel coil using SSL RF resonators was also simulated and provides good parallel excitation performance. In addition, RF shimming for homogenization can be effectively controlled by adjusting the inputs of eight resonators. Numerical results were obtained using a spherical phantom and a realistic human body model at 3T to calculate B-1(+) fields.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] A novel RF resonator for human-body MRI at 3 T
    Hyeok-Woo Son
    Young-Ki Cho
    Hyoungsuk Yoo
    Journal of the Korean Physical Society, 2014, 64 : 813 - 816
  • [2] A novel RF resonator for human-body MRI at 3 T
    Son, Hyeok-Woo
    Cho, Young-Ki
    Yoo, Hyoungsuk
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (06) : 813 - 816
  • [3] Comparison of RF body coils for MRI at 3T: a simulation study using parallel transmission on various anatomical targets
    Wu, Xiaoping
    Zhang, Xiaotong
    Tian, Jinfeng
    Schmitter, Sebastian
    Hanna, Brian
    Strupp, John
    Pfeuffer, Josef
    Hamm, Michael
    Wang, Dingxin
    Nistler, Juergen
    He, Bin
    Vaughan, Thomas J.
    Ugurbil, Kamil
    Van de Moortele, Pierre-Francois
    NMR IN BIOMEDICINE, 2015, 28 (10) : 1332 - 1344
  • [4] Measurement and characterization of RF nonuniformity over the heart at 3T using body coil transmission
    Sung, Kyunghyun
    Nayak, Krishna S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (03) : 643 - 648
  • [5] Microstrip Transmission Line RF Coil for a PET/MRI Insert
    Akram, Md Shahadat Hossain
    Obata, Takayuki
    Yamaya, Taiga
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2020, 19 (02) : 147 - 153
  • [6] Improving Homogeneity for MRI RF Field at 3T Using a Huygens' Box
    Xue, Chen
    Zhou, Gabriel G. L.
    Wong, Alex M. H.
    2020 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION AND NORTH AMERICAN RADIO SCIENCE MEETING, 2020, : 915 - 916
  • [7] High-Density MRI RF Arrays Using Mixed Dipole Antennas and Microstrip Transmission Line Resonators
    Lu, Ming
    Sengupta, Saikat
    Gore, John C.
    Grissom, William A.
    Yan, Xinqiang
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (10) : 3243 - 3252
  • [8] Whole body MRI of the non-human primate using a clinical 3T scanner: initial experiences
    Li, Chun-Xia
    Zhang, Xiaodong
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2017, 7 (02) : 267 - 275
  • [9] Whole body sodium MRI at 3T using an asymmetric birdcage resonator and short echo time sequence: first images of a male volunteer
    Wetterling, Friedrich
    Corteville, Dominique M.
    Kalayciyan, Raffi
    Rennings, Andreas
    Konstandin, Simon
    Nagel, Armin M.
    Stark, Helmut
    Schad, Lothar R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (14): : 4555 - 4567
  • [10] A deep brain stimulation-conditioned RF coil for 3T MRI
    Kutscha, Nicolas
    Mahmutovic, Mirsad
    Bhusal, Bhumi
    Vu, Jasmine
    Chemlali, Chaimaa
    Hansen, Sam-Luca J. D.
    May, Markus W.
    Knake, Susanne
    Golestanirad, Laleh
    Keil, Boris
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (03) : 1411 - 1426