Effectiveness of the magnetostatic shielding by the cylindrical shells

被引:101
作者
Grabchikov, S. S. [1 ]
Trukhanov, A. V. [1 ]
Trukhanov, S. V. [1 ]
Kazakevich, I. S. [1 ]
Solobay, A. A. [1 ]
Erofeenko, V. T. [2 ]
Vasilenkov, N. A. [3 ]
Volkova, O. S. [4 ,5 ]
Shakin, A. [5 ]
机构
[1] NAS Belarus, SSPA Sci & Pract Mat Res Ctr, Minsk 220072, BELARUS
[2] BSU Inst Sci Res Inst Appl Problems Math & Inform, Minsk 220030, BELARUS
[3] CJSC TESTPRIBOR, Moscow 125362, Russia
[4] MSU, Low Temp Phys & Superconduct Dept, Moscow, Russia
[5] Natl Univ Sci & Technol MISiS, Moscow 119049, Russia
基金
俄罗斯基础研究基金会;
关键词
Magnetostatic shielding; Cylindrical shield; Electrolytically deposited Ni80Fe20 alloy; Effectiveness of the shielding; Vibration magnetometry; EXPRESSION;
D O I
10.1016/j.jmmm.2015.08.122
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The experimental research of the magnetostatic shielding effectiveness and the analytical calculations of the average magnetic permeability of single layer cylindrical sample of the shields based on electrolytically deposited Ni80Fe20 alloy are carried out. The locations of maxima on the Ef(H) and mu(H) curves do not match each other, which is difficult to interpret in terms of the shunting model. The results are explained by the non-linear distribution of the magnetic permeability through the thickness of the shield, It has been shown that in the magnetic fields range from 100 A/m up to 2700 A/m, the shields based on the Ni80Fe20 alloy are preferred over ones based on the 84KHSR amorphous ribbon. It is concluded that at the selection of shield materials it should Lake into account not only the main magnetic characteristics - mu; IIs; IIc but also IImax parameter, which is important to evaluate the effectiveness of magnetic shielding. (C) 2015 Elsevier B.V. All tights reserved.
引用
收藏
页码:49 / 53
页数:5
相关论文
共 16 条
[1]   SYSTEMATIC DESIGN OF MAGNETIC-SHIELDS [J].
BAUM, E ;
BORK, J .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 1991, 101 (1-3) :69-74
[2]   Numerical and experimental development of multilayer magnetic shields [J].
Bavastro, Davide ;
Canova, Aldo ;
Giaccone, Luca ;
Manca, Michele .
ELECTRIC POWER SYSTEMS RESEARCH, 2014, 116 :374-380
[3]  
Bosanquet, 1883, PHILOS MAG, V15, P205
[4]   Expression of the axial magnetic attenuation for a circularly cylindrical magnetic shield with partial openings [J].
Chang, LH ;
Wang, C ;
Luo, GH ;
Lin, MC .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2002, 239 (1-3) :591-594
[5]  
Erofeenko V.T., 2012, INFORMATIKA, V35, P80
[6]   DC shielding efficiency of spherical shells with holes [J].
Füzi, J ;
Iványi, A ;
Szabó, Z .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2003, 254 :237-240
[7]   Magnetic shielding analysis of a multiply-slotted metal plate coated with a ferrite sheet in a periodic line current source [J].
Park, Hyun Ho ;
Kwon, Jong Hwa ;
Kwak, Sang Il ;
Ahn, Seungyoung .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2015, 385 :250-256
[8]  
Purcell E., 1985, Electricity and Magnetism, V2nd ed.
[9]  
Ramsden E., 2006, Hall-Effect Sensors, V2nd, P1
[10]  
Reitz J.R., 1993, FDN ELECTROMAGNETIC, P59