Determination of finasteride and its metabolite in urine by dispersive liquid-liquid microextraction combined with field-enhanced sample stacking and sweeping

被引:9
作者
Chen, Chun-Hsien [1 ]
Chao, Yu-Ying [2 ]
Lin, Yi-Hui [3 ]
Chen, Yen-Ling [1 ,4 ,5 ,6 ]
机构
[1] Kaohsiung Med Univ, Coll Pharm, Dept Fragrance & Cosmet Sci, Kaohsiung, Taiwan
[2] Kaohsiung Med Univ, Coll Hlth Sci, Dept Publ Hlth, Kaohsiung, Taiwan
[3] China Med Univ, Coll Pharm, Sch Pharm, Taichung, Taiwan
[4] Natl Sun Yat Sen Univ, Dept Marine Biotechnol & Resources, Coll Marine Sci, Kaohsiung, Taiwan
[5] Kaohsiung Med Univ, Res Ctr Environm Med, Kaohsiung, Taiwan
[6] Kaohsiung Med Univ Hosp, Dept Med Res, Kaohsiung, Taiwan
关键词
Androgenetic alopecia; Finasteride; Dispersive liquid-liquid microextraction; Field-enhanced sample stacking and sweeping; GAS-CHROMATOGRAPHY; MASS-SPECTROMETRY; ANDROGENETIC ALOPECIA; STEROIDS; PLASMA;
D O I
10.1016/j.chroma.2018.03.008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The on-line preconcentration technique of field-enhanced sample stacking and sweeping (FESS-sweeping) are combined with dispersive liquid-liquid microextraction (DLLME) to monitor the concentrations of finasteride, which is used in the treatment of androgenetic alopecia, and its metabolite, finasteride carboxylic acid (M3), in urine samples. DLLME is used to concentrate and eliminate the interferences of urine samples and uses chloroform as an extracting solvent and acetonitrile as a disperser solvent. A high conductivity buffer (HCB) was introduced into capillary and then sample plug (90.7% capillary length) was injected into capillary. After applying voltage, the sodium dodecyl sulfate (SDS) swept the analytes from the low conductivity sample solution into HCB. The analytes were concentrated on the field-enhanced sample stacking boundary. The limit of detection for the analytes is 20 ngmL(-1). The sensitivity enrichment of finasteride and M3 are 362-fold and 480-fold, respectively, compared with the conventional MEKC method. The on-line preconcentration technique of field-enhanced sample stacking and sweeping possess good selectivity because the endogenous steroid did not interfere the detection of finasteride and M3. The analytical technique is applied to investigate the concentrations in urine samples from patients who have been administered finasteride for the treatment of androgenetic alopecia; the amount of M3 detected in 12 h was 72.69 +/- 4.18 mu g. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:14 / 20
页数:7
相关论文
共 29 条
[1]  
[Anonymous], AM J ANAL CHEM
[2]  
[Anonymous], 2004, PROD INF PROPECIAR O
[3]   Complementary on-line preconcentration strategies for steroids by capillary electrophoresis [J].
Britz-McKibbin, P ;
Ichihashi, T ;
Tsubota, K ;
Chen, DDY ;
Terabe, S .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1013 (1-2) :65-76
[4]   STABILITY-INDICATING MICELLAR ELEKTROKINETIC CHROMATOGRAPHY METHOD FOR DETERMINATION OF FINASTERIDE IN PHARMACEUTICAL PREPARATIONS [J].
Caglayan, Mehmet Gokhan ;
Palabiyik, Ismail Murat ;
Onur, Feyyaz .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2013, 36 (06) :781-791
[5]   An on-line stacking capillary electrophoresis method for the analysis of Δ9-tetrahydrocannabinol and its metabolites [J].
Cheng, Hui-Ling ;
Tsai, Yi-Hsuan ;
Hsu, Wan-Ling ;
Lin, Yi-Hui .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1426 :226-232
[6]   THE EFFECT OF FINASTERIDE, A 5-ALPHA-REDUCTASE INHIBITOR, ON SCALP SKIN TESTOSTERONE AND DIHYDROTESTOSTERONE CONCENTRATIONS IN PATIENTS WITH MALE PATTERN BALDNESS [J].
DALLOB, AL ;
SADICK, NS ;
UNGER, W ;
LIPERT, S ;
GEISSLER, LA ;
GREGOIRE, SL ;
NGUYEN, HH ;
MOORE, EC ;
TANAKA, WK .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1994, 79 (03) :703-706
[7]   Liquid chromatography and supercritical fluid chromatography as alternative techniques to gas chromatography for the rapid screening of anabolic agents in urine [J].
Desfontaine, Vincent ;
Novakova, Lucie ;
Ponzetto, Federico ;
Nicoli, Raul ;
Saugy, Martial ;
Veuthey, Jean-Luc ;
Guillarme, Davy .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1451 :145-155
[8]  
Elzouki A.Y., 2012, TXB CLIN PEDIAT, P1489
[9]   Centrifuge microextraction coupled with sweeping-MEKC to analyze trace steroid hormones in urine samples [J].
Fang, Huaifang ;
Yang, Fangxing ;
Sun, Junling ;
Tian, Yun ;
Zeng, Zhaorui ;
Xu, Ying .
TALANTA, 2011, 85 (04) :2148-2153
[10]   EFFECTS OF FINASTERIDE (MK-906), A 5-ALPHA-REDUCTASE INHIBITOR, ON CIRCULATING ANDROGENS IN MALE-VOLUNTEERS [J].
GORMLEY, GJ ;
STONER, E ;
RITTMASTER, RS ;
GREGG, H ;
THOMPSON, DL ;
LASSETER, KC ;
VLASSES, PH ;
STEIN, EA .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1990, 70 (04) :1136-1141