A Robust Doppler Spectral Envelope Detection Technique for Automated Blood Flow Measurements

被引:1
|
作者
Kathpalia, Aditi [1 ]
Karabiyik, Yucel [1 ]
Simensen, Bente [2 ]
Tegnander, Eva [2 ,3 ]
Eik-Nes, Sturla [2 ,3 ]
Torp, Hans [1 ]
Ekroll, Ingvild Kinn [1 ]
Kiss, Gabriel [1 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Circulat & Med Imaging, N-7034 Trondheim, Norway
[2] St Olavs Hosp, Natl Ctr Fetal Med, Trondheim, Norway
[3] Norwegian Univ Sci & Technol, Dept Lab Med Childrens & Womens Hlth, N-7034 Trondheim, Norway
来源
2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS) | 2015年
关键词
Doppler ultrasound; maximum velocity envelope estimation; power spectrum; FREQUENCY ESTIMATORS; VELOCITY; US;
D O I
10.1109/ULTSYM.2015.0419
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Maximum velocity estimation in a Doppler Spectrogram is of clinical interest. Two existing approaches to maximum velocity estimation, the Geometric method (GM) and the Signal Noise Slope Intersection (SNSI) method are combined in the new approach described in this paper. Further, a data adaptive validity check is introduced that makes the proposed technique independent of user defined parameters. The method enables accurate maximum velocity point detection and obtains an automated, robust tracing of the maximum velocity envelope, which can be further used for automated blood flow measurements. In order to verify the robustness of the algorithm, Pulsatility Index measurements were compared with the observations made by a midwife trained in ultrasound. Evaluation of the steadiness of the location of identified maximum frequency point in simulated flow with varying SNR, ranging to a minimum SNR level of 6dB, also aided the verification. This technique is expected to prove useful in ultrasound machines for diagnoses by clinically inexperienced users.
引用
收藏
页数:4
相关论文
共 48 条
  • [1] Amplitude Doppler US: Slow blood flow detection tested with a flow phantom
    Weskott, HP
    RADIOLOGY, 1997, 202 (01) : 125 - 130
  • [2] Flow Rate and Low Hematocrit Measurements for In Vitro Blood Processing With Doppler Ultrasound
    Pialot, Baptiste
    Gachelin, Jeremie
    Tanter, Mickael
    Provost, Jean
    Couture, Olivier
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (07) : 1293 - 1302
  • [3] Automated Aortic Doppler Flow Tracing for Reproducible Research and Clinical Measurements
    Zolgharni, Massoud
    Dhutia, Niti M.
    Cole, Graham D.
    Bahmanyar, M. Reza
    Jones, Siana
    Sohaib, S. M. Afzal
    Tai, Sarah B.
    Willson, Keith
    Finegold, Judith A.
    Francis, Darrel P.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (05) : 1071 - 1082
  • [4] Accuracy of spectral doppler flow and tissue velocity measurements in ultrasound systems
    Walker, A
    Olsson, E
    Wranne, B
    Ringqvist, I
    Ask, P
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (01) : 127 - 132
  • [5] Variability of Doppler ultrasound measurements of hindlimb blood flow in conscious horses
    Raisis, AL
    Young, LE
    Meire, HB
    Taylor, PM
    Walsh, K
    Lekeux, P
    EQUINE VETERINARY JOURNAL, 2000, 32 (02) : 125 - 132
  • [6] Normal pediatric testis: Comparison of power Doppler and color Doppler US in the detection of blood flow
    Barth, RA
    Shortliffe, LD
    RADIOLOGY, 1997, 204 (02) : 389 - 393
  • [7] Reconstruction of maximum blood flow velocity waveforms from Doppler ultrasound measurements
    Fernando, KL
    Mathews, VJ
    Clark, EB
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 124 - 125
  • [8] Measurements of common iliac arterial blood flow in Anurans using Doppler ultrasound
    Willens, Scott
    Dupree, Sloan H.
    Stoskopf, Michael K.
    Lewbart, Gregory A.
    JOURNAL OF ZOO AND WILDLIFE MEDICINE, 2006, 37 (02) : 97 - 101
  • [9] Repeatability of Doppler ultrasound measurements of hindlimb blood flow in halothane anaesthetised horses
    Raisis, AL
    Young, LE
    Meire, H
    Walsh, K
    Taylor, PM
    Lekeux, P
    EQUINE VETERINARY JOURNAL, 2000, 32 (03) : 239 - 246
  • [10] Quantitative Measurement of Blood Flow Dynamics in Embryonic Vasculature Using Spectral Doppler Velocimetry
    Davis, Anjul
    Izatt, Joseph
    Rothenerg, Florence
    ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2009, 292 (03): : 311 - 319