Interfacial bond-slip behaviour between reinforced high-strength concrete and built-in steel plate with studs

被引:14
作者
Dong, Hongying [1 ]
Zhao, Yizhou [1 ]
Cao, Wanlin [1 ]
Chen, Xuepeng [1 ]
Zhang, Jianwei [1 ]
机构
[1] Beijing Univ Technol, Coll Architecture & Civil Engn, Beijing 100124, Peoples R China
基金
国家重点研发计划; 北京市自然科学基金;
关键词
Bond-slip behaviour; Steel plate; High-strength concrete (HSC); Recycled aggregate concrete (RAC); Stud; Push-out test; SHEAR CONNECTORS; STATIC BEHAVIOR; TESTS;
D O I
10.1016/j.engstruct.2020.111317
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel-plate-reinforced concrete composite shear walls have been widely used in high-rise and super-high-rise buildings. To improve the bond behaviour between the steel plate and high-strength concrete (HSC) in shear walls, 13 steel-plate HSC shear wall (SPHSCSW) specimens with group studs were designed for push-out tests. Specimens were constructed using HSC or high-strength recycled aggregate concrete (HSRAC). Concrete strength, concrete type, stud length-to-diameter ratio, and replacement of studs with tie bar connectors are considered. The influence of different parameters on the interfacial bond behaviour of specimens is discussed by analysing the load-slip curves, bond strength, and interface damage energy dissipation. The equations for the shearing capacity of studs and the interfacial bond-slip constitutive relationship under different connectors were obtained. Results show that the influence of concrete strength on the bond strength of SPHSCSWs is positively correlated, and the bond behaviour with HSRAC is similar to that of normal HSC. When the stud length-to diameter ratio exceeds four, increasing the ratio has little effect on improving the shearing capacity, and a further increase reduces the residual bond strength. Replacing some studs with tie bars can significantly improve the residual bond strength and interfacial bond energy dissipation capacity. The proposed equations for the shearing capacity of studs in SPHSCSWs and the bond-slip constitutive relationship agree well with the test results, which can be used for engineering applications and further research.
引用
收藏
页数:14
相关论文
共 36 条
[21]   Static behavior of large stud shear connectors [J].
Shim, CS ;
Lee, PG ;
Yoon, TY .
ENGINEERING STRUCTURES, 2004, 26 (12) :1853-1860
[22]   Push-off tests on pin-connected shear studs with composite steel-concrete beams [J].
Tahir, Mahmood Md ;
Shek, Poi Ngian ;
Tan, Cher Siang .
CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (09) :3024-3033
[23]   Bond behavior in concrete-filled steel tubes [J].
Tao, Zhong ;
Song, Tian-Yi ;
Uy, Brian ;
Han, Lin-Hai .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2016, 120 :81-93
[24]  
Thurlimann B., 1959, J AM CONCRETE I, P1287, DOI DOI 10.14359/11421
[25]  
Viest IM, 1956, J. Am. Concr. Inst, V52, P875, DOI [10.14359/11655, DOI 10.14359/11655]
[26]  
WANG B, 2013, J ENG MECH, V30, P54
[27]   Seismic Behavior of Steel Plate Reinforced Concrete Composite Shear Walls under Tension-Bending-Shear Combined Cyclic Load [J].
Wang, Jia-Ji ;
Tao, Mu-Xuan ;
Fan, Jian-Sheng ;
Nie, Xin .
JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (07)
[28]  
Wu K, 2019, CHINA CIV ENG J, V52
[29]   Parametrical static analysis on group studs with typical push-out tests [J].
Xu, Chen ;
Sugiura, Kunitomo ;
Wu, Chong ;
Su, Qingtian .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 72 :84-96
[30]  
Xu JJ, 2013, J BUILD STRUCT, V07, P152