Contribution to the Fault Diagnosis of a Doubly Fed Induction Generator for a Closed-loop Controlled Wind Turbine System Associated with a Two-level Energy Storage System

被引:6
作者
Attoui, Issam [1 ,2 ]
Omeiri, Amar [2 ,3 ]
机构
[1] Welding & NDT Res Ctr, Cheraga, Algeria
[2] Badji Mokhtar Annaba Univ, Dept Elect Engn, Annaba, Algeria
[3] Badji Mokhtar Annaba Univ, Lab Elect Engn Annaba, Lab Electrotech LEA, Annaba, Algeria
关键词
two-level energy storage system; fault detection and diagnosis; adaptive Fast Fourier transform; doubly fed induction generator; fractional-order control; wind energy conversion systems; POWER; EFFICIENCY;
D O I
10.1080/15325008.2014.950361
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
-In this article, a contribution to the fault diagnosis of a doubly fed induction generator for a closed-loop controlled wind turbine system associated with a two-level energy storage system using an on-line fault diagnostic technique is proposed. This technique is proposed to detect the rotor fault in the doubly fed induction generator under non-stationary conditions based on the spectral analysis of stator currents of the doubly fed induction generator by an adaptive fast Fourier transform algorithm. Furthermore, to prevent system deterioration, a fractional-order controller with a simple design method is used for the control of the whole wind turbine system. The fractional-order controller ensures that the system is stable in both healthy and faulty conditions. Additionally, to improve the production capacity under wind speed fluctuations and grid demand changes, a two-level energy storage system consisting of a supercapacitor bank and lead-acid batteries is proposed. The obtained simulation results show that the objectives of the fault diagnosis procedure and control strategy are reached.
引用
收藏
页码:1727 / 1742
页数:16
相关论文
共 45 条
[21]   A Fast Inductance Computation Devoted to the Modeling of Healthy, Eccentric, and Saturated Induction Motors [J].
Ghoggal, Adel ;
Sahraoui, Mohamed ;
Zouzou, Salah Eddine ;
Razik, Hubert .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2013, 41 (10) :1002-1022
[22]   Experimental validation of doubly fed induction machine electrical faults diagnosis under time-varying conditions [J].
Gritli, Yasser ;
Stefani, Andrea ;
Rossi, Claudio ;
Filippetti, Fiorenzo ;
Chatti, Abderrazak .
ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (03) :751-766
[23]  
IMBERGER J, 1986, J PHYS OCEANOGR, V16, P1997, DOI 10.1175/1520-0485(1986)016<1997:AOTWDT>2.0.CO
[24]  
2
[25]   Synchronous Generator Off-line Diagnosis Approach Including Fault Detection and Estimation of Failures on Machine Parameters [J].
Lalami, Abdelhalim ;
Wamkeue, Rene .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2013, 41 (15) :1501-1517
[26]   A Fractional Order Proportional and Derivative (FOPD) Motion Controller: Tuning Rule and Experiments [J].
Li, HongSheng ;
Luo, Ying ;
Chen, YangQuan .
IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2010, 18 (02) :516-520
[27]   Tuning fractional order proportional integral controllers for fractional order systems [J].
Luo, Ying ;
Chen, Yang Quan ;
Wang, Chun Yang ;
Pi, You Guo .
JOURNAL OF PROCESS CONTROL, 2010, 20 (07) :823-831
[28]  
Lurie BJ, 1994, US Patent, Patent No. [US5371670, 5371670]
[29]   Integrating energy storage with wind power in weak electricity grids [J].
McDowall, Jim .
JOURNAL OF POWER SOURCES, 2006, 162 (02) :959-964
[30]   Architecture complexity and energy efficiency of small wind turbines [J].
Mirecki, Adam ;
Roboam, Xavier ;
Richardeau, Feredric .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (01) :660-670