Contribution to the Fault Diagnosis of a Doubly Fed Induction Generator for a Closed-loop Controlled Wind Turbine System Associated with a Two-level Energy Storage System

被引:6
作者
Attoui, Issam [1 ,2 ]
Omeiri, Amar [2 ,3 ]
机构
[1] Welding & NDT Res Ctr, Cheraga, Algeria
[2] Badji Mokhtar Annaba Univ, Dept Elect Engn, Annaba, Algeria
[3] Badji Mokhtar Annaba Univ, Lab Elect Engn Annaba, Lab Electrotech LEA, Annaba, Algeria
关键词
two-level energy storage system; fault detection and diagnosis; adaptive Fast Fourier transform; doubly fed induction generator; fractional-order control; wind energy conversion systems; POWER; EFFICIENCY;
D O I
10.1080/15325008.2014.950361
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
-In this article, a contribution to the fault diagnosis of a doubly fed induction generator for a closed-loop controlled wind turbine system associated with a two-level energy storage system using an on-line fault diagnostic technique is proposed. This technique is proposed to detect the rotor fault in the doubly fed induction generator under non-stationary conditions based on the spectral analysis of stator currents of the doubly fed induction generator by an adaptive fast Fourier transform algorithm. Furthermore, to prevent system deterioration, a fractional-order controller with a simple design method is used for the control of the whole wind turbine system. The fractional-order controller ensures that the system is stable in both healthy and faulty conditions. Additionally, to improve the production capacity under wind speed fluctuations and grid demand changes, a two-level energy storage system consisting of a supercapacitor bank and lead-acid batteries is proposed. The obtained simulation results show that the objectives of the fault diagnosis procedure and control strategy are reached.
引用
收藏
页码:1727 / 1742
页数:16
相关论文
共 45 条
[1]   Supercapacitor energy storage for wind energy applications [J].
Abbey, Chad ;
Joos, Geza .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2007, 43 (03) :769-776
[2]  
[Anonymous], 1993, INTRO FRACTIONAL CA
[3]  
[Anonymous], 16792010 IEEE POW EN
[4]   Neural Network Model Reference Adaptive System Speed Estimation for Sensorless Control of a Doubly Fed Induction Generator [J].
Antonio Cortajarena, Jose ;
De Marcos, Julian .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2013, 41 (12) :1146-1158
[5]   Modeling, control and fault diagnosis of an isolated wind energy conversion system with a self-excited induction generator subject to electrical faults [J].
Attoui, Issam ;
Omeiri, Amar .
ENERGY CONVERSION AND MANAGEMENT, 2014, 82 :11-26
[6]   Time-frequency feature extraction of a cracked shaft using an adaptive kernel [J].
Behzad, M. ;
Ghias, A. R. .
MODERN PRACTICE IN STRESS AND VIBRATION ANALYSIS VI, PROCEEDINGS, 2006, 5-6 :37-+
[7]   A review of induction motors signature analysis as a medium for faults detection [J].
Benbouzid, ME .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2000, 47 (05) :984-993
[8]   A DSP-based FFT-analyzer for the fault diagnosis of rotating machine based on vibration analysis [J].
Betta, G ;
Liguori, C ;
Paolillo, A ;
Pietrosanto, A .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2002, 51 (06) :1316-1322
[9]  
Boashash B, 2003, TIME FREQUENCY SIGNAL ANALYSIS AND PROCESSING: A COMPREHENSIVE REFERENCE, P29, DOI 10.1016/B978-008044335-5/50023-1
[10]  
Bode H. W., 1945, NETWORK ANAL FEEDBAC